IR REMOTE OUTPUTS

1

SOURCE  OUTPUT

SUM  OUTPUT

A

2

B

3

C

4

D

INFRARED (IR) SECTION

16.) Source Output #1 through 4 -

 This 1/8” 2 conductor jack is for the IR emitters and are “locked”

source specific. This is useful in for instance, if you have 2 or more of the same brand CD player,

since the same IR command will work on both, this ONLY sends the IR command to this particular

source. Nearly any brand of emitter will work. There are four source specific IR jacks.

This connector is duplicated for the remaining 3 outputs and function exactly the same as the first

one.

17.) Sum Output #1 through 4 - 

This 1/8” 2 conductor jack is for the IR emitters and are summed

across the IR buss. This will allow normal operation of different components that don’t share the same

IR commands. There are four sum output IR jacks.

This connector is duplicated for the remaining 3 outputs and function exactly the same as the first

one..

18.) AC Power - 

This is where the AC power cord connects to the unit. It is a detachable 3 prong

I.E.C. plug. 

 

Never remove the ground lug on the plug or electrical shock and damage to the unit could

result.

16

17

18

INSTALLATION  NOTES

Use Category 5  8-conductor cable. It is not necessary for it to be shielded but be careful with

your cable runs. Avoid running a tight parallel with AC wiring. Be careful if stapling the wire to secure

it in place.

Use high quality RJ-45 connectors and make sure you use a high quality crimp tool. The crimp

of the RJ-45 connectors is crucial in making the system work properly.

Avoid tight or sharp turns near the ends of the RJ-45 connections to the controller or main

units. This can put excessive strain on already small wires.

Note when stacking multiple units: Audio sources connect via the distribution outputs. Wall

controllers combine via the Master Controller Out jack. Make a short jumper and connect to the second

unit’s Master Controller In jack to allow the “party” mode master controller to access all zones. For

the IR Emitters, we strongly suggest using a “Y” adapter for the emitters that attach directly from the

sources and then to the second unit’s IR outputs. This allows the source specific functionality to be

utilized by the second MDS-6. An additional controller can be run per zone by using a RJ-45 “Y”

adapter before the main unit.

Page 4

WIRING DIAGRAM FOR REMOTE ROOM CONTROLLERS

TO MCS-1 or MCS-2

DATA LINE C

DATA LINE B

DATA LINE A

+5 VOLT D.C.

GROUND

IR SIGNAL

CLONE

STANDBY

TO MDS-6

1

2

3

4

5

6

7

8

8

7

6

5

4

3

2

1

RJ-45

PLUG

RJ-45

PLUG

CLIP

CLIP

Содержание CHANNELPLUS MDS-6

Страница 1: ...ole house paging in conjunction with your phone system and built in front and back door chimes A party mode allows you to select music source and volume for all zones from one location A built in IR r...

Страница 2: ...ld be provided 13 Metal parts and vinyl covering may be cleaned with a damp rag 14 Care should be taken so that objects do not fall and liquids are not spilled into the unit through the ventilation po...

Страница 3: ......

Страница 4: ...ker terminals and line outputs E Distribution Section This section is the line level input output section It provides the inputs from your sources and the outputs for stacking additional units F Contr...

Страница 5: ...uggest using a straight blade Jeweler s screwdriver to easily make this connection These speaker outputs are rated at 20 watts RMS a side into an 8 ohm load Stay within that ohm rating This will be mo...

Страница 6: ...usly When the signal is disengaged the music will return to the previous level Even zones that are not currently on will open and allow the announcement to be made Inside the unit is a master DIP type...

Страница 7: ...18 INSTALLATION NOTES Use Category 5 8 conductor cable It is not necessary for it to be shielded but be careful with your cable runs Avoid running a tight parallel with AC wiring Be careful if staplin...

Страница 8: ...MDS 6 INSTALLATION MANUAL TM...

Страница 9: ...now see both the ON and the STANDBY LED S lit on the MDS 6 6 Now attach the zone 1 controller to the zone 1 controller input on the MDS 6 7 Now go to zone 1 controller If the source 1 equipment is pl...

Страница 10: ...the 12 pin terminal block located on the back of the unit Cat 5 wire or doorbell wire is perfectly suitable for all of these connections 1 Page Doorbell Status Paging The MDS 6 has two ways to allow...

Страница 11: ...page is engaged Factory setting is on Set to off if you don t wish to have sources muted when doorbell or page is activated such as a nursery etc Audio disables doorbell and page audio Factory settin...

Страница 12: ...SUPPLY IS NOT NEEDED USING ALTERNATE WIRING DOORBELL BUTTON Standard ChannelPlus Door Tel Phone System Wiring Diagram for Page When is struck audio will go out to the front door only When 5 is struck...

Страница 13: ...ED This LED indicates the power status of the system Lighted the system is on and ready Off the system is not engaged 5 Mute Button This button will instantly stop the audio through the system It is u...

Страница 14: ...place the controller into a ready to receive commands mode This is the learning mode When setting up the system initially place all but one controller in this mode and use the one master controller t...

Страница 15: ...ne Repeat as necessary This is a programmable button It may be reprogrammed to any function you want depending on the source 21 Power On This button will turn on the source power switch from whatever...

Страница 16: ...discretion of the installer Cloning The MCS 2 has a cloning feature that will allow you to down load the information stored in one controller to up to five additional controllers within an installatio...

Страница 17: ...grouped as a macro under the CD1 source button The following selections are made on the right side of the MCS 2 dual controller See diagram page 7 1 Press PWR button 2 Press the button programmed for...

Страница 18: ...ter press the command button on the MCS 1 Controller you wish to program into the wireless remote 6 The wireless remote should then accept the MCS 1 command 7 Once you have programmed the source numbe...

Страница 19: ...r the memory in case of a power outage No the MCS 2 controller has a non volatile memory that will retain its memory once the controller has been programmed How do I utilize the doorbell and page feat...

Страница 20: ...re runs of the controllers will have an increased time out of 15 minutes Once I have programmed my MCS 2 controller why does some of the source equipment not work It is possible that the MCS 2 did not...

Страница 21: ..._________________________________________________ Installer s Phone ___________________________ Source 1 ______________________________________ Source 2 ______________________________________ Source 3...

Страница 22: ...ot covered by this warranty This warranty will be void if a The unit has been altered or modified b The serial number has been removed or defaced c Original purchase is not from an Authorized Kustom D...

Отзывы: