C O N T R O L P A N E L S
Hold/Clean State
In this state, there is water in the tank, and its temperature is maintained at the
Hold
Temperature
. The pump speed in this mode is determined by the
Hold Pump Speed
. The
purpose of the Hold mode is to keep the dirt from settling back onto the dishes and also
serves to keep the oily water and soap from separating between washes.
Hold/Clean mode is active at the end of a Wash cycle. At that time, the 1
st
line of the
display will flash
C L E A N
, and the current water temperature on the 2
nd
line.
Should the water be drained in this mode, the unit returns to the Power-up state once it
detects the dry-fire condition that will exist.
While in Hold/Clean mode, the 5 cycle LED’s blink to indicate that a new cycle may now
be selected. The Heater status LED is active if needed. The Pump LED group is functional
according to the current Water Pump speed.
Pressing the Up/Down keys will light the Up/Down LED’s, and the current temperature
information will be replaced by the blinking set point temperature. The Up/Down keys
allow this value to be changed between 100° and 125°F (37° to 52°C). If no key is pressed
for 5 seconds, the display reverts to the current water temperature and the Up/Down
LED’s shut off. This new temperature will be stored until the next water change. At the
next drain/fill sequence, the Hold temperature is reset to the low-level programmed
temperature.
Pressing the Stop key will cause the unit to return to the OFF state.
Additional System Features
Internal Buzzer
The internal buzzer emits a very short beep whenever a key is pressed. This beep has an
adjustable volume for the key presses. However, 100% of the volume is used when signaling
alarms or other status changes.
Soap Injection Algorithm
This section explains how the various soap parameters interact. The idea is that the quantity
of soap per tank cannot exceed
Soap Maximum
. Thus, the control keeps track of the total
soap injection time, and resets this counter only in the Power-up state (when the tank is
emptied).
When a cycle is started, if the programmed soap quantity for this cycle is
Soap Minimum
, then
this amount of soap is added. If the cycle quantity programmed is
Soap Intermediate
or
Soap
Maximum
, then that quantity is injected.
If a new cycle is selected
before
the Power-up state is active (which resets the soap amount
counter), then the controller will add the difference in soap amounts if needed. Again, there
will never be more than
Soap Maximum
amount of soap in the water.
33
Содержание Taskmaster PP-3
Страница 2: ...Left Blank This Page Intentionally ...
Страница 12: ...O P E R A T I O N I N S T R U C T I O N S 11 NOTES ...
Страница 48: ...C O N T R O L P A N E L S 47 NOTES ...
Страница 52: ...M A I N T E N A N C E 51 NOTES ...
Страница 63: ...P A R T S L I S T 62 NOTES ...
Страница 64: ...P A R T S L I S T NOTES 63 ...
Страница 65: ...P A R T S L I S T NOTES 64 ...
Страница 66: ......
Страница 67: ...Champion Industries PO Box 4149 Winston Salem NC 27115 336 661 1556 www championindustries com ...