100430 - 6500W ELECTRIC START GENERATOR
STORAGE
30
Mid Term Storage (30 days – 1 year)
Ethanol blended gasoline in the tank has a maximum shelf life
of up to 1 year with the addition of a properly formulated fuel
stabilizer and stored in a cool, dry place.
1. Be sure all appliances are disconnected from the generator.
2. Add a properly formulated fuel stabilizer to the gasoline tank.
3. Turn the fuel valve to the “ON” position.
4. Start and run the generator for 10 minutes so the treated
gasoline cycles through the fuel system.
5.
Option 1: Drain Gasoline from Carburetor
5a. Turn ignition switch to the “OFF” position and allow
generator to cool completely before continuing.
5b. Turn the fuel valve to the “OFF” position.
5c. Use the drain bolt on the carburetor to empty any
excess gasoline from the carburetor into an appropriate
container. Use a funnel (and appropriate hose if
necessary) under the carburetor drain bolt to avoid
spillage.
5d. When gasoline stops flowing from the carburetor, replace
and tighten the carburetor drain bolt and be sure to
properly dispose of the drained gasoline according to
local regulations or guidelines.
6.
Option 2: Run Dry
6a. With the generator running, turn the fuel valve to the
“OFF” position and allow the generator to run until the
engine stops from complete fuel starvation. This may
take a few minutes.
6b. Turn ignition switch to the “OFF” position and allow
generator to cool completely before continuing.
7. Remove the spark plug cap and spark plug and pour about a
tablespoon of oil into the cylinder.
8. Pull the recoil cord slowly to crank the engine to distribute the
oil and lubricate the cylinder.
9. Install the spark plug and spark plug cap.
10. Clean the generator according to Cleaning the Generator.
11. Store the generator in a cool, dry place out of direct sunlight.
Long Term Storage (over 1 year)
For storage over 1 year, the gasoline tank and carburetor must be
completely drained of gasoline.
1. The generator is to be OFF and all appliances disconnected.
2. Turn the fuel valve to the “ON” position.
3. Use the drain bolt on the carburetor to empty any excess
gasoline from the gasoline tank and carburetor into an
appropriate container. Use a funnel (and appropriate hose if
necessary) under the carburetor drain bolt to avoid spillage.
4. When gasoline stops flowing from the carburetor, replace
and tighten the carburetor drain bolt and be sure to properly
dispose of the drained gasoline according to local regulations
or guidelines.
5. Turn the fuel valve to the “OFF” position.
6. Follow steps 7-11 according to
Mid
Term Storage.
Removing from Storage
NOTICE
If the generator has been improperly stored for a period
longer than 30 days with ethanol blended gasoline in the
gasoline tank and/or carburetor, all fuel must be drained
and the carburetor must be thoroughly cleaned of ethanol
build up. This process involves technically advanced tasks.
For assistance please call our Technical Support Team at
1-877-338-0999.
If the gasoline tank and carburetor were properly emptied of all
ethanol blended gasoline prior to the generator being stored,
follow the below steps when removing from storage.
1. Be sure the ignition switch is in the “OFF” position.
2. Add gasoline to the generator according to
Add Fuel.
3. Turn the fuel valve to the “ON” position.
4. After 5 minutes check the carburetor and air filter areas for
any leaking gasoline. If any leaks are found, the carburetor
will need to be disassembled and cleaned or replaced. If no
gasoline leaks are found, turn the fuel valve to the “OFF”
position.
5. Check engine oil level and add clean, fresh oil if needed. See
Oil Specifications
for proper oil type.
6. Check and clear air filter of any obstructions such as bugs or
cobwebs. If necessary, clean air filter according to
Cleaning
the Air Filter.
7. Start the generator according to