SAFETY RULES

Improper treatment or use of the generator can 
damage it, shorten its life and void your warranty.

Use the generator only for intended uses.
Operate only on level surfaces.
DO NOT expose generator to excessive moisture, 
dust, or dirt.
DO NOT allow any material to block the cooling slots.
If connected devices overheat, turn them off and 
disconnect them from the generator.
DO NOT use the generator if:

 

– Electrical output is lost

 

– Equipment sparks, smokes or emits flames

 

– Equipment vibrates excessively

CAUTION

Operation of this equipment may create sparks that 

can start fires around dry vegetation.

A spark arrestor may be required. The operator 

should contact local fire agencies for laws or 

regulations relating to fire prevention requirements.

WARNING

Rapid retraction of the starter cord will pull hand and 
arm towards the engine faster than you can let go. 
Unintentional startup can result in entanglement, 
traumatic amputation or laceration.  
Broken bones, fractures, bruises or sprains could result.

When starting engine, pull the starter cord slowly 
until resistance is felt and then pull rapidly to avoid 
kickback.
DO NOT start or stop the engine with electrical 
devices plugged in.

WARNING

Exceeding the generator’s running capacity can 
damage the generator and/or electrical devices 
connected to it.

DO NOT overload the generator.
Start the generator and allow the engine to stabilize 
before connecting electrical loads.
Connect electrical equipment in the off position, 
and then turn them on for operation.
Turn electrical equipment off before stopping the 
generator.
DO NOT tamper with the governed speed. 
DO NOT modify the generator in any way.

CAUTION

Fuel and fuel vapours are highly flammable and 
extremely explosive. 
Fire or explosion can cause severe burns or death.  
Unintentional startup can result in entanglement, 
traumatic amputation or laceration. 

When adding or removing fuel:

Turn the generator off and let it cool for at least two 
minutes before removing the fuel cap. Loosen the 
cap slowly to relieve pressure in the tank.
Only fill or drain fuel outdoors in a well-ventilated area.
DO NOT pump gas directly into the generator at the 
gas station. Use an approved container to transfer 
the fuel to the generator.
DO NOT overfill the fuel tank.
Always keep fuel away from sparks, open flames, 
pilot lights, heat and other sources of ignition.
DO NOT light or smoke cigarettes.

When starting the generator:

DO NOT attempt to start a damaged generator. 
Make certain that the gas cap, air filter, spark plug, 
fuel lines and exhaust system are properly in place.
Allow spilled fuel to evaporate fully before 
attempting to start the engine.
Make certain that the generator is resting firmly on 
level ground.

When operating the generator:

DO NOT move or tip the generator during operation.
DO NOT tip the generator or allow fuel or oil to spill.

When transporting or servicing the generator:

Make certain that the fuel shutoff valve is in the off 
position and the fuel tank is empty.
Disconnect the spark plug wire.

When storing the generator:

Store away from sparks, open flames, pilot lights, 
heat and other sources of ignition.

DANGER

Содержание 75555i

Страница 1: ...999 www championpowerequipment com PORTABLE INVERTER GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual MADE IN CHINA REV 75555i 20140110 3100 Max Watts 2800 R...

Страница 2: ...Care Team Toll Free at 1 877 338 0999 AN IMPORTANT MESSAGE ABOUT TEMPERATURE Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40 C 10...

Страница 3: ...age 12 Engine Maintenance 12 Oil 12 Spark Plugs 12 Air Filter 13 Cleaning 13 Spark Arrester 13 Adjustments 13 Maintenance Schedule 13 Generator Maintenance 14 Storage 14 Generator Storage 14 Specifica...

Страница 4: ...information available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most fro...

Страница 5: ...y hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided...

Страница 6: ...s metal decking Use approved transfer equipment to isolate generator from your electric utility and notify your utility company before connecting your generator to your power system DANGER Sparks can...

Страница 7: ...al equipment in the off position and then turn them on for operation Turn electrical equipment off before stopping the generator DO NOT tamper with the governed speed DO NOT modify the generator in an...

Страница 8: ...Cap Remove to add fuel 2 Recoil Starter Used to start the engine 3 Power Panel 4 Muffler 5 Maintenance Cover 6 Never Flat Wheels 7 Carrying Handle Inverter CONTROLS AND FEATURES Parts Included Your 75...

Страница 9: ...ctrical overload 9 Oil Warning Light Check oil level when this light turns on Engine will not run when indicator is lit 10 Overload Indicator Light This light turns ON when the generator is overloaded...

Страница 10: ...cover 5 Check engine oil level daily and add as needed 3 Remove oil fill cap dipstick to add oil 4 Add 0 6 qt 0 6 L of oil and replace oil fill cap dipstick DO NOT OVERFILL The recommended oil type is...

Страница 11: ...fuel Use regular unleaded gasoline with a minimum octane rating of 85 Do not mix oil and gasoline Fill tank to approximately 6 4 mm in below the top of the tank to allow for fuel expansion DO NOT pump...

Страница 12: ...bed of a truck regular flat or otherwise under staircases stairwells next to walls or buildings or in any other location that will not allow for adequate cooling of the generator and or the muffler DO...

Страница 13: ...will be connected to a building electrical system consult your local utility company or a qualified electrician Connections must isolate generator power from utility power and must comply with all ap...

Страница 14: ...on 6 Turn the fuel cap lever vent to the Off position after the generator has cooled down completely Important Always ensure that the Fuel Valve and the Engine Switch are in the OFF position when the...

Страница 15: ...to remove the plug 4 Remove the spark plug 5 Inspect the electrode on the plug It must be clean and not worn to produce the spark required for ignition 6 Make certain the spark plug gap is 0 7 0 8 mm...

Страница 16: ...frequently when operating in adverse conditions Contact our help line at 1 877 338 0999 to locate the nearest Champion Power Equipment certified service dealer for your generator or engine maintenanc...

Страница 17: ...attach the spark plug 11 Store the unit in a clean dry place out of direct sunlight MAINTENANCE AND STORAGE Generator Maintenance Make certain that the generator is kept clean and stored properly Only...

Страница 18: ...FD 33 Displacement 171cc Type 4 Stroke OHV Start Type Recoil Spark Plugs OEM spark plug NHSP F6RTC Replacement spark plug NGK BPR6ES or equivalent Make certain the spark plug gap is 0 7 0 8 mm or 0 02...

Страница 19: ...9 5 8 7 5 5 21752 81 7 3257 5 2 6 57 7 50 1 3 5 7 50 1 2 9 6 67 33 1 02725 63 5 1 3 8 6723 6 5 2 8 5 1 5 7 U 7 8 5 1 2 7 5 1 52 1 7 1 5 725 1 1 5 37 2 68 2 2 2 2 5 5 5 5 7 81 7 5 5 51 7 21 0 7 67 2 2...

Страница 20: ...17 REV 75555i 20140110 ENGLISH 75555i Parts Diagram SPECIFICATIONS...

Страница 21: ...2 006 Flange Nut M14 1 5 1 58 83 191100 01 Rotor Assembly 1 59 1 5789 0645 Flange Bolt M6 45 4 60 83 191200 10 Stator Assembly Cu DC12V CSA 1 61 83 190002 01 End Cover Mortor 1 Part Number Description...

Страница 22: ...77 76 75 74 73 48 49 50 51 52 54 56 57 58 59 62 61 63 64 66 68 69 72 33 32 29 30 28 26 25 47 46 45 44 43 42 41 40 38 37 36 96 93 100 99 92 91 90 89 88 24 23 21 20 19 18 17 16 15 14 13 12 1 2 3 4 5 6...

Страница 23: ...her Drain Bolt 10 16 1 5 1 51 2 08 037 Bolt Drain M10 1 25 25 1 52 83 030009 01 Gasket Cylinder Head 1 Part Number Description Qty 53 2 04 003 Dowel Pin 10 14 2 54 83 040006 01 Valve Exhaust 1 55 83 0...

Страница 24: ...shuts down during operation Out of fuel Fill fuel tank Low oil level Fill crankcase to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Gene...

Страница 25: ...labour if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any elec...

Страница 26: ...ject to provisions set forth below If during the warranty period emission related part on your engine is defective in materials or workmanship the part will be repaired or replaced by CPE OWNER WARRAN...

Страница 27: ...ll be warranted for the remainder of the ECS Warranty Period c Any warranted emissions related part which is scheduled for replacement as required maintenance in the Owner s Manual shall be warranted...

Страница 28: ...talled along with your warranty registration card or other proof of original purchase date at your expense to any Champion Power Equipment dealer who is authorized by Champion Power Equipment Inc to s...

Отзывы: