![background image](http://html1.mh-extra.com/html/champion/46512/46512_owners-manual-and-operating-instructions_2588873009.webp)
REV 46512-20110301
6
46512
ENGLISH
Power Panel
1
5
6
7
8
3
(1) Intelligauge
– Three mode digital meter for running
hours, voltage and hertz .
(2) Ignition Switch
(3) Circuit Breaker(s)
– Protects the generator against
electrical overload .
(4) Battery Switch
– Enables/disables starting
electrically – via remotely or by Ignition Switch .
(5) Ground Terminal
– Consult an electrician for local
grounding regulations .
(6) 120V / 30A Twist-Lock
– This receptacle powers
120 Volt AC, 60 Hz, single phase loads requiring
up to 29 .2 Amps or 3500 Watts of power .
(7) 120V / 30A Recreational Vehicle (RV) Receptacle
–
This receptacle powers 120 Volt AC, 60 Hz, single
phase loads requiring up to 29 .2 Amps or 3500
Watts of power .
(8) 120V / 20A Duplex
– Protected by a 20 Amp
push-to-reset circuit breaker . Use each recepticle
to operate 120 Volt AC, single phase, 60 Hz loads
requiring up to 20 Amp 0r 2400 Watts of power .
2
CONTROLS ANd fEATuRES
4