100806 - 7500W ELEcTRic START GENERATOR
cONTROLS AND fEATURES
13
control Panel
1.
Ignition Switch
– Used to START or STOP the generator.
2.
Intelligauge
– Four mode digital meter for displaying voltage,
frequency, run time, and total run time.
3.
Circuit Breakers (Flip Reset)
– Protects the generator
against electrical overloads.
4.
Circuit Breakers (Push Reset)
– Protects the generator
against electrical overloads.
RECEPTACLES
A
W
120V AC, 30A Locking (NEMA L5-30R)
May be used to supply electrical power for
operation of 120 Volt AC, 30 Amp, single phase,
60 Hz electrical loads.
B
Y
120/240V AC, 30A Locking (NEMA L14-30R)
May be used to supply electrical power for
operation of 120/240 Volt AC, 30 Amp, single
phase, 60 Hz electrical loads.
C
C
(4×) 120V AC, 20A GFCI (NEMA 5-20R)
May be used to supply electrical power for
operation of 120 Volt AC, 20 Amp, single phase,
60 Hz electrical loads.
1
3
4
2
A
b
c