100806 - 7500W ELEcTRic START GENERATOR
OPERATiON
19
NOTicE
This blinking does not indicate CO Shield is working, as CO
Shield is working at all times the generator is running. Also,
the LED will not blink (10) times if the generator was restarted
within 1 minute after it was manually shut off. This does not
occur if generator shut off from a high CO event.
If CO Shield system experiences a fault and no longer provides
protection, the generator is shutoff automatically and the
yellow
LED light will blink for at least five (5) minutes to notify you of the
fault.
AUTOMATIC SHUTOFF
SEE ACTION LABEL
ARRÊT AUTOMATIQUE
VOIR L'ÉTIQUETTE D'ACTION
AUTOMATIC SHUTOFF
SEE ACTION LABEL
ARRÊT AUTOMATIQUE
VOIR L'ÉTIQUETTE D'ACTION
SERVICE
EFFECTUER L’ENTRETIEN
SERVICE
EFFECTUER L’ENTRETIEN
AUTOMATIC SHUTOFF
SEE ACTION LABEL
ARRÊT AUTOMATIQUE
VOIR L'ÉTIQUETTE D'ACTION
AUTOMATIC SHUTOFF
SEE ACTION LABEL
ARRÊT AUTOMATIQUE
VOIR L'ÉTIQUETTE D'ACTION
SERVICE
EFFECTUER L’ENTRETIEN
SERVICE
EFFECTUER L’ENTRETIEN
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOMÁTICO
VEA ETIQUETA DE ACCIÓN
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOMÁTICO
VEA ETIQUETA DE ACCIÓN
SERVICE
REALICE UN SERVICIO
SERVICE
REALICE UN SERVICIO
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOMÁTICO
VEA ETIQUETA DE ACCIÓN
AUTOMATIC SHUTOFF
SEE ACTION LABEL
APAGADO AUTOMÁTICO
VEA ETIQUETA DE ACCIÓN
SERVICE
REALICE UN SERVICIO
SERVICE
REALICE UN SERVICIO
Call our Technical Support Team at 1-877-338-0999 for repair.
The generator can be restarted, but will continue to shutoff.
CO Shield will detect the accumulation of carbon monoxide from
other fuel burning sources such as engine powered tools, or
propane heaters used in the area of operation. If another generator
is used and the exhaust is pointed at a CO Shield equipped
generator, the CO Shield may initiate a shutoff due to rising carbon
monoxide levels. This is not a fault. Hazardous carbon monoxide
has been detected. You must take action to move and direct the
equipment to better dissipate carbon monoxide far away from
people or buildings.
WARNiNG
Tampering with the CO Shield™ system could result in a
hazardous condition and will void your warranty.
Removing the CO Shield module will not allow the generator to
start.
Generator Location
WARNiNG
NEVER operate the generator inside any building, garage,
basement, crawlspace, shed, enclosure or compartment,
including a generator compartment of a recreational vehicle.
NEVER operate or start the generator in the back of an
SUV, camper, trailer, truck bed (regular sides, flat or other
configuration), under staircases, stairwells, next to walls
or buildings or in any other location that will not allow for
adequate cooling of the generator or for the proper exit of the
exhaust flow from the muffler system.
DO NOT operate or store the generator in wet weather
conditions such as rain or snow. Using a generator in wet
conditions could result in serious injury or death due to
electrocution.
In some state’s generators may be required to be registered
with the local utility company when used at construction sites
and may be subject to additional rules and regulations, consult
your local municipal authority.
Generators should always be operated on a flat, level surface
at all times (even when not in operation).
Generators must have a minimum of 5 feet (1.5 m) of
clearance from all combustible material.
Generators must also have a minimum of 3 feet (91.4 cm)
of air flow clearance on all sides to allow for adequate
performance cooling, maintenance and servicing.
Always place the generator in a well-ventilated area. NEVER
place the generator near air intake vents or where exhaust
fumes could be drawn into occupied or confined spaces.
Always carefully consider wind and air currents when
positioning generator.
Always allow generators to properly cool before transport or
for storage purposes.
Failure to follow proper safety precautions may result in
personal injury, damage to the generator and void the
manufacturer’s warranty.