100423 - WIRELESS REMOTE START GENERATOR

CONTROLS AND FEATURES

10

Generator Panel Symbols

The below symbols are located on the generator power panel. 
Familiarize yourself with these symbols for quick reference of 
the components and their function.

Symbol

Meaning

i

ON

r

START

s

STOP or OFF

d

OFF

H

Battery Switch

Q

Ingition Switch

v

Voltmeter

n

Circuit Breaker Reset: Push

o

RV Ready Receptacle

Z

Locking Receptacle

w

Wirless Reset

Wireless Remote Control

This generator is equipped with a wireless remote control 
system for starting and stopping. The system consists of (4) 
main components:

1.  Receiver Control Module (RCM)

2.  Wireless Remote

3.  Battery Switch

4.  Ignition Switch

The Remote Control functions are enabled when:

1.  The Ignition Switch is in the “ON” position, AND

2.  The Battery Switch is in the “ON” position.

The Remote Control functions are disabled if either of the above 
conditions is not met.

To start the generator by Remote Control, press the “START” 
button on the Remote one time. The engine will attempt to 
start (6) times. The RCM controls the Auto Choke during each 
attempt to start. If the generator does not start, call Champion 
Customer Care team for assistance at 1-877-338-0999.

To stop the generator by Remote Control, press the “STOP” 
button on the Remote one time.

Remote Control Power Consumption

While the Ignition Switch is in the “ON: position, the RCM is 
active and waiting for a remote signal. This function requires 
electrical current from the battery. If the Ignition Switch is left 
in the “ON” position for extended periods (several weeks), the 
battery can be completely drained. 

Moving the Ignition Switch to the “OFF” position disables the 
Remote functions, but the RCM still consumes approximately 2 
mA from the battery.

To prevent battery drain, press the Battery Switch to the “OFF” 
position. This disconnects power to the RCM so there is no 
current draw on the battery.

Generator Panel Load Management

When the generator initially starts by the Remote, no voltage is 
supplied to the Generator Panel for approximately 15 seconds. 
This allows the engine to reach full speed before electrical loads 
are applied to the generator. 

When the generator is stopped by the Remote, the voltage to 
the Generator Panel is immediately turned off. Then the engine 
stops approximately 5 seconds after the “STOP” button on the 
Remote is pressed. Turning the Generator Panel voltage off 
before the engine shutdown protects connected appliances 
from being damaged by non-60 Hz voltage while the generator 
coasts to a stop.

The on/off voltage delay at startup and shut down only 
happen when the Remote Control is used. There is no 
voltage delay when the pushbutton electric start or recoil 
start method is used.

When the pushbutton electric start or recoil start method is 
used, the operator must be sure all electrical loads (appliances) 
are turned OFF during startup and shutdown. Damage to the 
generator or the attached appliances can be caused by starting 
or stopping the generator while appliances are plugged in and 
turned ON.

Содержание 100423

Страница 1: ...ad and understood before operating the product Failure to do so could result in serious injury This manual should remain with the product Specifications descriptions and illustrations in this manual a...

Страница 2: ...g the Engine 15 Battery 16 Connecting Electrical Loads 16 Do Not Overload Generator 16 Stopping the Engine 17 Operation at High Altitude 17 Maintenance 17 Cleaning the Generator 18 Changing the Engine...

Страница 3: ...ore each use Please always exercise common sense and always err on the side of caution when operating the product to ensure no accident property damage or injury occurs We want you to continue to use...

Страница 4: ...at could become caught WARNING Operation of this equipment may create sparks that can start fires around dry vegetation A spark arrestor may be required The operator should contact local fire agencies...

Страница 5: ...s excessively WARNING Medical and life support uses In case of emergency call 911 immediately NEVER use this product to power life support devices or life support appliances NEVER use this product to...

Страница 6: ...generator DO NOT overfill the gasoline tank Always keep gasoline away from sparks open flames pilot lights heat and other sources of ignition DO NOT light or smoke cigarettes When starting the generat...

Страница 7: ...aces stoves water heaters or other appliances that have a pilot light or other ignition source because they can ignite the fuel FOR USE IN A WEATHER PROTECTED AREA ONLY DO NOT EXPOSE TO RAIN Operating...

Страница 8: ...start the engine for wireless start and electric start 4 Air Filter Protects the engine by filtering dust and debris from the intake air 5 Recoil Starter Used to manually start the engine 6 Never Flat...

Страница 9: ...nables disables starting electrically Receptacles A W 120V AC 30A Locking NEMA L5 30R May be used to supply electrical power for operation of 120 Volt AC 30 Amp single phase 60 Hz electrical loads B t...

Страница 10: ...his function requires electrical current from the battery If the Ignition Switch is left in the ON position for extended periods several weeks the battery can be completely drained Moving the Ignition...

Страница 11: ...und to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential...

Страница 12: ...Repeat to attach the second Wheel Install the Support Leg 1 Attach the Support Leg D to the generator frame with Flange Bolts E and Flange Lock Nuts F 2 Slowly tip the generator back down so that it r...

Страница 13: ...hreshold level NOTICE The first 5 hours of run time are the break in period for the unit During the break in period stay at or below 50 of the running watt rating and vary the load occasionally to all...

Страница 14: ...help prevent electric shock WARNING Failure to properly ground the generator can result in electric shock A ground terminal has been provided on the lower frame crossmember below the alternator For r...

Страница 15: ...inst virtually all short duration voltage fluctuations Starting the Engine 1 Make certain the generator is on a flat level surface 2 Disconnect all electrical loads from the generator Never start or s...

Страница 16: ...ing but it is also recommended that the battery be fully charged at least once per month Connecting Electrical Loads Let the engine stabilize and warm up for a few minutes after starting Plug in and t...

Страница 17: ...ly 3 for every 1000 ft of elevation above sea level This is a natural trend and cannot be changed by adjusting the engine At high altitudes increased exhaust emissions can also result due to the incre...

Страница 18: ...mm socket and extension not included 2 Allow the oil to drain completely into an appropriate container 3 Replace the oil drain plug 4 Remove the oil fill cap dipstick to add oil MAX MIN OIL DIP STICK...

Страница 19: ...th an automatic battery charging circuit The battery will receive charging voltage when the engine is running The battery will maintain a proper charge if the unit is used on a regular basis about onc...

Страница 20: ...ll appliances are disconnected from the generator 2 Add a properly formulated fuel stabilizer to the gasoline tank 3 Turn the fuel valve to the ON position or for Dual Fuel models only set the fuel se...

Страница 21: ...tion or for Dual Fuel models ONLY set the fuel selector switch for operation on gasoline 4 After 5 minutes check the carburetor and air filter areas for any leaking gasoline If any leaks are found the...

Страница 22: ...il used based on weather conditions to suit the engine needs Fuel Specifications Use regular unleaded gasoline with a minimum octane rating of 85 and an ethanol content of less than 10 by volume DO NO...

Страница 23: ...9 30 31 32 34 35 36 37 38 39 40 41 42 43 2 3 4 5 6 7 8 9 10 11 14 15 10 16 12 17 18 51 52 53 54 55 56 57 64 65 66 67 75 77 19 20 22 21 50 50 76 78 44 33 13 58 59 60 61 62 63 45 46 48 68 69 70 71 73 74...

Страница 24: ...1 31 122 070015 01 Mount Vibration Fuel Tank 4 32 2 03 004 1 Flat Washer 24 x 6 5 x 1 5 Black 4 33 1 93 06 Lock Washer 6 4 Part Number Description Qty 34 1 5789 0620 1 Flange Bolt M6 x 20 Black 4 35 2...

Страница 25: ...ter 1 83 1 848 03 2 Washer 3 4 84 1 859 03 2 Lock Washer 3 4 85 1 6175 03 2 Nut M3 4 86 5 1460 003 Pilot Lamp 1 87 5 1040 004 Remote Excercise Button 1 88 5 1210 930 30Amp Circuit Breaker Push Button...

Страница 26: ...41 42 43 44 46 47 21 22 23 24 31 34 36 39 53 52 45 51 50 49 55 56 57 58 54 60 62 61 63 65 66 67 68 69 70 71 72 74 25 93 94 95 92 91 90 97 78 79 80 82 83 84 85 86 87 88 76 59 12 77 96 33 81 73 106 54...

Страница 27: ...buretor 1 35 27 080600 01 Air Guide Right Side 1 36 2 01 003 Stud Bolt M6 x 90 2 37 27 030100 01 Crankcase 1 Part Number Description Qty 38 21 127000 02 Oil Level Sensor 1 39 26 010100 01 Cylinder Hea...

Страница 28: ...1 95 23 020001 02 Breather Tube 112 35 1 96 1 5789 0615 Flange Bolt M6 x 15 4 97 2 01 010 Stud Bolt M8 x 35 2 98 23 030006 00 Plate Coil 1 99 27 091200 01 Cover Air Cleaner Black 1 100 23 091003 21 El...

Страница 29: ...IT BREAKER EXW FW MW1 L Y Y AVR Br 30A EARTH TERMINAL R w w G Y Y Y L L R W w 120V L5 30R R R R R R w B MW2 Y B G Y G Y R PILOT LAMP BUTTON Transition Receiver module W W C stepper motor L C Y O R B B...

Страница 30: ...on Out of fuel Fill fuel tank Low oil level Fill crankcase to the proper level Place generator on a flat level surface Generator cannot supply enough power or overheating Generator is overloaded Revie...

Страница 31: ...quired to be performed at a facility or by a person authorized by CPE Other Exclusions This warranty excludes Cosmetic defects such as paint decals etc Wear items such as filter elements o rings etc A...

Страница 32: ...l system is warranted for two years subject to provisions set forth below If during the warranty period emission related part on your engine is defective in materials or workmanship the part will be r...

Страница 33: ...ement point for that part If the part fails prior to the first scheduled replacement the part shall be repaired or replaced by CPE according to Subsection d below Any such emissions related part repai...

Страница 34: ...ets Carburetor Purge Port Connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your warranty registration card or other proof of origin...

Отзывы: