background image

3

  

REV 41351-20130318

ENGLISH

 

41351

SAfETy RULES

Generator exhaust contains carbon monoxide, a 
colorless, odorless, poison gas. Breathing carbon 
monoxide will cause nausea, dizziness, fainting or 
death. If you start to feel dizzy or weak, get to fresh 
air immediately.

Operate generator outdoors only in a well ventilated 
area.
DO NOT operate the generator inside any building, 
including garages, basements, crawlspaces and 
sheds, enclosure or compartment, including the 
generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confined 
area through windows, doors, vents or other 
openings.
DANGER CARBON MONOXIDE: using a generator 
indoors

 CAN KILL YOU IN MINUTES.

DANGER

Rotating parts can entangle hands, feet, hair, 
clothing and/or accessories. 
Traumatic amputation or severe laceration can result.

Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
Operate equipment with guards in place.
DO NOT wear loose-fitting clothing, dangling 
drawstrings or items that could become caught.

DANGER

Generator produces powerful voltage.

DO NOT touch bare wires or receptacles.

DO NOT use electrical cords that are worn, damaged 

or frayed.

DO NOT operate generator in wet weather.

DO NOT allow children or unqualified persons to 

operate or service the generator

Use a ground fault circuit interrupter (GFCI) in damp 

areas and areas containing conductive material such 

as metal decking.

Use approved transfer equipment to isolate generator 

from your electric utility and Notify your utility 

company before connecting your generator to your 

power system.

DANGER

Sparks can result in fire or electrical shock.

When servicing the generator:

Disconnect the spark plug wire and place it where it 

cannot contact the plug.

DO NOT check for spark with the plug removed.

Use only approved spark plug testers.

WARNING

Running engines produce heat. Severe burns can 

occur on contact. 

Combustible material can catch fire on contact.

DO NOT touch hot surfaces.

Avoid contact with hot exhaust gases.

Allow equipment to cool before touching.

Maintain at least three feet of clearance on all sides 

to ensure adequate cooling.

Maintain at least five feet of clearance from 

combustible materials.

WARNING

Medical and Life Support Uses.

In case of emergency, call 911 immediately.
NEVER use this product to power life support 
devices or life support appliances.
NEVER use this product to power medical devices 
or medical appliances.
Inform your electricity provider immediately if you 
or anyone in your household depends on electrical 
equipment to live.
Inform your electrical provider immediately if a 
loss of power would cause you or anyone in your 
household to experience a medical emergency.

WARNING

The engine exhaust from this product contains 
chemicals known to the state of California to cause 
cancer, birth defects, or other reproductive harm.

WARNING

Read this manual thoroughly before operating your 
generator. Failure to follow instructions could result 
in serious injury or death.

WARNING

Содержание 100107

Страница 1: ...e Springs CA 90670 USA 1 877 338 0999 www championpowerequipment com SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual MADE IN CHINA REV 41351 20130318 41351 MODEL NUMB...

Страница 2: ...e Team Toll Free at 1 877 338 0999 AN IMPORTANT MESSAGE ABOUT TEMPERATURE Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40 C 104 F...

Страница 3: ...Filter 14 Spark Arrester 15 Cleaning 15 Adjustments 15 Maintenance Schedule 15 Generator Maintenance 15 Storage 16 Generator Storage 16 Disconnect the Battery 16 Charge the Battery 16 Specifications 1...

Страница 4: ...information available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most fro...

Страница 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided m...

Страница 6: ...metal decking Use approved transfer equipment to isolate generator from your electric utility and Notify your utility company before connecting your generator to your power system DANGER Sparks can r...

Страница 7: ...l equipment in the off position and then turn them on for operation Turn electrical equipment off before stopping the generator DO NOT tamper with the governed speed DO NOT modify the generator in any...

Страница 8: ...he engine 3 Fuel Valve Turn this valve to the ON position to supply fuel to the engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intake air 5 Recoil Starter Used to start...

Страница 9: ...ds 3 120 240V 30A Twist Lock Receptacle NEMA L14 30R May be used to supply electrical power for the operation of 120 and or 240 Volt AC 30 Amp single phase 60 Hz electrical loads 4 120V 20A Duplex NEM...

Страница 10: ...t 10 in Wheel 2 Bushing 2 Flange Bolt M10x120 for Wheel 2 Flat Washer 10 2 Nut M10 2 Support Leg w vibration mounts 1 Flange Bolt M8x25 for Vibration Mounts 2 Flange Bolt M8x16 for Support Leg 2 Nut M...

Страница 11: ...tools to install the wheels 17 mm wrench OR adjustable wrench not included Socket wrench with a 16 mm socket not included Pliers not included 1 Before adding fuel and oil tip the generator on it s si...

Страница 12: ...oil shut off and will stop when the oil level in the crankcase falls below the threshold level CAUTION DO NOT attempt to crank or start the engine before it has been properly filled with the recommend...

Страница 13: ...warranty It is advisable to always shut off the fuel supply run the engine to fuel starvation and drain the tank when the equipment is not in use for more than 30 days NOTE Add Fuel Cont d Add Fuel 1...

Страница 14: ...ay be subject to additional rules and regulations Generators should be on a flat level surface at all times Even while not in operation Generators must have at least five feet of clearance from all co...

Страница 15: ...must isolate generator power from utility power and must comply with all applicable laws and codes NOTE Operation Starting the Engine 1 Make certain the generator is on a flat level surface 2 Disconn...

Страница 16: ...cal load attached 2 Allow the engine to run for several minutes to stabilize 3 Plug in and turn on the first item It is best to attach the item with the largest load first 4 Allow the engine to stabil...

Страница 17: ...p dipstick to add oil 5 Add 1 16 qt 1 1 L of oil and replace oil fill cap dipstick DO NOT OVERFILL 6 Dispose of used oil at an approved waste management facility Spark Plugs 1 Remove the spark plug ca...

Страница 18: ...gh the cooling slots and damage the generator windings CAUTION Maintenance Schedule Follow the service intervals indicated in the following maintenance schedule Service your generator more frequently...

Страница 19: ...or longer term storage please follow these guidelines Generator Storage 1 Add a properly formulated fuel stabilizer to the tank 2 Be sure all appliances are disconnected from the generator 3 Run the g...

Страница 20: ...the valve adjustment procedure is on www championpowerequipment com Spark Plugs OEM spark plug NHSP F6RTC Replacement spark plug NGK BPR6ES or equivalent Make certain the spark plug gap is 0 7 0 8 mm...

Страница 21: ...REV 41351 20130318 18 41351 ENGLISH Wiring Diagram Specifications...

Страница 22: ...23 24 25 26 27 28 29 25 30 31 32 33 32 34 35 36 37 38 39 40 41 42 43 25 31 44 46 47 48 49 79 84 85 86 87 88 52 89 90 91 92 93 94 95 68 71 72 73 74 76 77 78 80 50 53 14 54 55 56 57 58 59 60 61 62 63 6...

Страница 23: ...ne 1 50 5 1900 029 Grounding Line 1 51 1 5789 0612 1 Flange Bolt M6 12 5 52 1 862 06 Lock Washer 6 2 53 152 201200 00 Motor Mount 2 54 1 894 1 10 Circlip 10 2 Part Number Description Qty 55 152 200703...

Страница 24: ...5 10 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 16 24 25 26 27 28 29 30 31 33 34 35 12 36 30 37 38 23 39 41 42 43 44 46 47 48 49 50 51 52 53 12 54 55 57 58 59 60 61 62 65 66 68 69 70 71 72 73 74...

Страница 25: ...02 F6RTC Spark Plug F6RTC 1 58 2 08 014 Flange Bolt M10 80 4 59 46 020002 00 Gasket Cylinder Head Cover 1 Part Number Description Qty 60 46 021000 00 Cylinder Head Cover CPE 1 61 45 020001 02 Breather...

Страница 26: ...Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly connected Check all connections Connected...

Страница 27: ...this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorrectly to any electrical com...

Страница 28: ...ject to provisions set forth below If during the warranty period emission related part on your engine is defective in materials or workmanship the part will be repaired or replaced by CPE OWNER WARRAN...

Страница 29: ...all be warranted for the remainder of the ECS Warranty Period c Any warranted emissions related part which is scheduled for replacement as required maintenance in the Owner s Manual shall be warranted...

Страница 30: ...talled along with your warranty registration card or other proof of original purchase date at your expense to any Champion Power Equipment dealer who is authorized by Champion Power Equipment Inc to s...

Отзывы: