Champion Pump CPSE10 Series Скачать руководство пользователя страница 3

USER GUIDE  

 

Congratulations on your purchase of a Champion Pump.  With proper care and by following a few simple guidelines, your  
pump will give you many years of dependable service.  

USE & CARE The Champion Effluent & Sewage pumps are designed to handle routine, domestic effluent & sewage.  
Solid waste materials should be thrown in the trash. While your station is capable of accepting and pumping a wide range 
of materials, regulatory agencies advise that the following items should not be introduced into any sewer either directly or 
through a kitchen waste disposal: glass; metal; diapers; socks, rags or cloth; plastic objects (e.g., toys, utensils, etc.) 
sanitary napkins or tampons.  

In addition you must never introduce into any sewer:  Explosives; flammable material; lubricating oil and or grease; 
strong chemicals; gasoline.  

POWER FAILURE This pump cannot dispose of wastewater or provide an alarm signal without electrical power.  If 
electrical power service is interrupted, keep water usage to a minimum.  

WARRANTY Your pump is furnished with a warranty against defects in material or workmanship. A properly completed 
Start-Up/Warranty Registration form must be on file at the Champion factory in order to activate your warranty.   In 
addition, your pump must be installed in accordance with the installation instructions. If you have a claim under the 
provisions of the warranty, contact your installer.    

For future reference, record the following information:  

Pump Model #____________________Pump Serial # ______________________ 
Installer_________________________Installer Phone #____________________ Date 
Installed____________________  

RECEIVING / UNPACKING Upon receiving the pump, it should be inspected for damage or shortages. If damage has 
occurred, file a claim immediately with the company that delivered the pump.  Unpack pump and record pump serial and 
model number before installing. If the manual is removed from the packaging, do not lose or misplace.  

SHORT TERM STORAGE For best results, pumps can be retained in storage, as factory assembled, in a dry atmosphere 
with constant temperatures for up to six (6) Months. 

LONG TERM STORAGE Any length of time exceeding six (6) months, but not more than twenty-four (24) months.  The 
units should be stored in a temperature controlled area, a roofed over walled enclosure that provides protection from the 
elements (rain, snow, wind-blown dust, etc.), and whose temperature can be maintained b40 deg. F and +120 
deg.F. If extended high humidity is expected to be a problem, all exposed parts should be inspected before storage and all 
surfaces that have the paint scratched, damaged, or worn should be recoated with an air dry enamel paint.  All surfaces 
should then be sprayed with a rust-inhibiting oil.  Pump should be stored in its original shipping container.  On initial start 
up, rotate shaft by hand to assure seal and motor rotate freely.   

 

 
 
 
 
 
 

Page 3  

 

Содержание CPSE10 Series

Страница 1: ......

Страница 2: ......

Страница 3: ...he provisions of the warranty contact your installer For future reference record the following information Pump Model ____________________Pump Serial ______________________ Installer__________________...

Страница 4: ...r winding thermal protection Thermal protection shall not be used as a motor overload device A separate motor overload device must be provided in accordance with NEC Codes In the event of an overload...

Страница 5: ...al Chamber Oil Drain all oil from seal chamber and dispose of properly per local and environmental standards Set unit on its side with plug upward and refill with new oil approximately 13oz Apply pipe...

Страница 6: ...upply High AMPS 1 Incorrect voltage 4 Excessive inflow or pump not properly sized for application 8 Impeller clogged loose on shaft worn or damaged inlet plugged 12 Excessive water temperature 16 Impr...