Start-Up Report / Warranty Registration  

 

Please fill out the following questions as completely and accurate as possible.  Please mail 
to Champion Pump Company,  Inc. – P. O. Box 528 – Ashland,  OH 44805.  

REPORTS THAT ARE NOT RETURNED CAN DELAY OR VOID WARRANTY.  

Pump Owner’s 
Name:__________________________________________________________________ 
Address:________________________________________________________________ 
Location of installation:____________________________________________________ 
Phone:__________________________________________________________________ 
Purchased from:__________________________________________________________  

Pump Model_______________Serial #__________________Date Code:_____________  

Date Installed:____________________________________________________________  

Does impeller turn freely by hand? YES____________NO___________________  

Condition of cord jacket? Good________Fair________________Poor_____________  

Was equipment stored?___________How long?_________________________________ 
Liquid being pumped______________________________________________________ 
Debris in bottom of station?________Was debris removed in your presence?__________  

Discharge pipe size?___________ Length of pipe?_________Static lift?_____________  

Does station appear to operate at the proper rate?_______Pump down time?___________  

Voltage At Wiring Terminal  L1-L2__________L2-L3__________L1-L3__________ 
Run Amps  L1_______________L2_______________L3_______________ 
3 Phase Models – Check Proper Rotation?   Yes / NO 
 
Difficulties during start up: 
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________
____________________________________________________________________________ 
I certify this report to be accurate (start up person)____________________________________ 
Employed by___________________________________ Date: _________________________  

Page 11 

Содержание CPSE10 Series

Страница 1: ......

Страница 2: ......

Страница 3: ...he provisions of the warranty contact your installer For future reference record the following information Pump Model ____________________Pump Serial ______________________ Installer__________________...

Страница 4: ...r winding thermal protection Thermal protection shall not be used as a motor overload device A separate motor overload device must be provided in accordance with NEC Codes In the event of an overload...

Страница 5: ...al Chamber Oil Drain all oil from seal chamber and dispose of properly per local and environmental standards Set unit on its side with plug upward and refill with new oil approximately 13oz Apply pipe...

Страница 6: ...upply High AMPS 1 Incorrect voltage 4 Excessive inflow or pump not properly sized for application 8 Impeller clogged loose on shaft worn or damaged inlet plugged 12 Excessive water temperature 16 Impr...

Страница 7: ...Page 7...

Страница 8: ...Page 8...

Страница 9: ...ron Upper Lower Carbon Ceramic SHAFT 416 Stainless Steel Buna N Elastomer MOTOR 1 PHASE 3450 RPM 60 Hz 300 Series Stainless Steel Hardware Includes Overload Protection In The Motor BEARING UPPER LOWER...

Страница 10: ......

Страница 11: ...oor_____________ Was equipment stored ___________How long _________________________________ Liquid being pumped______________________________________________________ Debris in bottom of station ______...