Champion Power Equipment 46539 Скачать руководство пользователя страница 6

3

  

REV 46539-20101109

ENGLISH

 

46539

SAfETy RuLES

The engine exhaust from this product contains 
chemicals known to the state of California to cause 
cancer, birth defects, or other reproductive harm .

Read this manual thoroughly before operating your 
generator . Failure to follow instructions could result 
in serious injury or death .

Generator exhaust contains carbon monoxide, a 
colorless, odorless, poison gas . Breathing carbon 
monoxide will cause nausea, dizziness, fainting or 
death . If you start to feel dizzy or weak, get to fresh 
air immediately .

Operate generator outdoors only in a well ventilated 
area .
DO NOT operate the generator inside any building, 
including garages, basements, crawlspaces and 
sheds, enclosure or compartment, including the 
generator compartment of a recreational vehicle .
DO NOT allow exhaust fumes to enter a confined 
area through windows, doors, vents or other 
openings .

DANGER CARBON MONOXIDE:

 using a generator 

indoors

 CAN KILL YOU IN MINUTES

 .

Rotating parts can entangle hands, feet, hair, 
clothing and/or accessories . 
Traumatic amputation or severe laceration can result .

Keep hands and feet away from rotating parts .
Tie up long hair and remove jewelry .
Operate equipment with guards in place .
DO NOT wear loose-fitting clothing, dangling 
drawstrings or items that could become caught .

Generator produces powerful voltage .

DO NOT touch bare wires or receptacles .
DO NOT use electrical cords that are worn, damaged 
or frayed .
DO NOT operate generator in wet weather .
DO NOT allow children or unqualified persons to 
operate or service the generator
Use a ground fault circuit interrupter (GFCI) in damp 
areas and areas containing conductive material such 
as metal decking .
Use approved transfer equipment to isolate generator 
from your electric utility and Notify your utility 
company before connecting your generator to your 
power system .

Sparks can result in fire or electrical shock .

When servicing the generator:

Disconnect the spark plug wire and place it where it 
cannot contact the plug .
DO NOT check for spark with the plug removed .
Use only approved spark plug testers .

Running engines produce heat . Severe burns can 
occur on contact . 
Combustible material can catch fire on contact .

DO NOT touch hot surfaces .
Avoid contact with hot exhaust gases .
Allow equipment to cool before touching .
Maintain at least three feet of clearance on all sides 
to ensure adequate cooling .
Maintain at least five feet of clearance from 
combustible materials .

dANGER

dANGER

dANGER

WARNING

WARNING

WARNING

WARNING

Содержание 46539

Страница 1: ...USA 1 877 338 0999 www championpowerequipment com 4000 Peak Watts 3500 Running Watts PORTABLE GENERATOR SAvE THESE INSTRuCTIONS Important Safety Instructions are included in this manual MADE IN CHINA...

Страница 2: ...he store WE ARE HERE TO HELP Visit our website www championpowerequipment com for more info Product Info Updates Frequently Asked Questions Tech Bulletins Product Registration or Call our Customer Car...

Страница 3: ...Remote 12 Connecting Electrical Loads 13 Stopping the Engine 13 Do Not Overload Generator 14 Capacity 14 Power Management 14 Wattage Reference Chart 14 Maintenance and Storage 15 Engine Maintenance 15...

Страница 4: ...rmation available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from you...

Страница 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided m...

Страница 6: ...nd remove jewelry Operate equipment with guards in place DO NOT wear loose fitting clothing dangling drawstrings or items that could become caught Generator produces powerful voltage DO NOT touch bare...

Страница 7: ...ull hand and arm towards the engine faster than you can let go Unintentional startup can result in entanglement traumatic amputation or laceration Broken bones fractures bruises or sprains could resul...

Страница 8: ...the engine No manual adjustment required 3 Vac Fuel Valve Turn this valve to the On position to supply fuel to the engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intak...

Страница 9: ...ounding regulations 6 120V 30A Twist Lock Protected by a 25 Amp push to reset circuit breaker This receptacle powers 120 Volt AC 60 Hz single phase loads requiring up to 29 2 Amps or 3500 Watts of pow...

Страница 10: ...er the STOP button on the Remote is pressed Turning the Power Panel voltage off before the engine shutdown protects connected appliances from being damaged by non 60 Hz voltage while the generator coa...

Страница 11: ...lange Bolt M10x105 for Wheel 2 Flange Bolt M8x45 for Handle 2 Flange Bolt M8x25 for Vibration Mounts 2 Flange Bolt M8x16 for Support Leg 2 Nut M10 2 Flat Washer 10 2 Nut M8 6 Spark Arrester Kit Spark...

Страница 12: ...erything from the carton except the generator 3 Carefully cut each corner of the box from top to bottom Fold each side flat on the ground to provide a surface area to install the wheel kit and support...

Страница 13: ...cap screw M6x10 and secure with the lock washer M6 3 Repeat steps 1 2 for the black battery lead Install the Spark Arrester Insert the spark arrester screen into the muffler outlet Secure the spark ar...

Страница 14: ...tane rating of 85 Do not mix oil and gasoline Fill tank to approximately inch below the top of the tank to allow for fuel expansion DO NOT fill fuel tank indoors DO NOT fill fuel tank when the engine...

Страница 15: ...e fluctuation may impair the proper functioning of sensitive electronic equipment CAUTION Operation Starting the Engine without Remote 1 Make certain the generator is on a flat level surface 2 Turn of...

Страница 16: ...receptacles is turned off and the engine will stop after 5 seconds Connecting a generator to your electric utility company s power lines or to another power source may be against the law In addition...

Страница 17: ...epeat steps 5 6 for each additional item Never exceed the specified capacity when adding loads to the generator NOTE Operation Wattage Reference Chart Use the chart to determine approximate wattage re...

Страница 18: ...clean engine oil 5 Squeeze in a clean absorbent cloth to remove all excess oil 6 Place the filter in the assembly 7 Reattach the air filter cover and snap in place Spark Plugs 1 Remove the spark plug...

Страница 19: ...PSI to clear dirt and debris from the engine Every 8 hours or daily Check oil level Clean around air intake and muffler First 5 Hours Change oil Every 50 hours or every season Clean air filter Change...

Страница 20: ...nspect all air vents and cooling slots to ensure that they are clean and unobstructed DO NOT use a garden hose to clean the generator Water can enter the generator through the cooling slots and damage...

Страница 21: ...t interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and o...

Страница 22: ...19 REV 46539 20101109 ENGLISH 46539 Specifications Parts Diagram...

Страница 23: ...68 070014 01 Rollover Valve Hose 1 55 ST168FD 1070400 CARB Rollover Valve 1 56 GB819 M5 10 Screw M5 10 2 57 ST02FD 04120000 CARB Fuel Meter Assembly 1 58 ST188FD 1741002 C Handle Sheath 1 Part Number...

Страница 24: ...21 REV 46539 20101109 ENGLISH 46539 Specifications Engine Parts Diagram...

Страница 25: ...03 Separator 1 54 ST168FD 1090002 Air Cleaner Seal 1 55 ST168FD 1090004 CARB Air Cleaner Case Comp 1 56 ST160F 1130003 CPE Carburetor Packing No Asbestos 1 57 ST168F 1130001 LPG Carburetor Insulator 1...

Страница 26: ...23 REV 46539 20101109 ENGLISH 46539 Wiring Diagram Specifications...

Страница 27: ...Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly connected Check all connections Connected...

Страница 28: ...y to parts and or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorr...

Страница 29: ...luding diagnosis parts and labor MANUFACTURER S EMISSION CONTROL SYSTEM WARRANTY COVERAGE This emission control system is warranted for two years subject to provisions set forth below If during the wa...

Страница 30: ...n such written instructions to the effect of repair or replace as necessary shall not reduce the ECS Warranty Period Any such part repaired or replaced under the ECS Warranty shall be warranted for th...

Страница 31: ...lities or to obtain warranty service please write or call the Customer service of Champion Power Equipment Inc Champion Power Equipment Inc ATTN Customer Service 10006 Santa Fe Springs Road Santa Fe S...

Отзывы: