7
REV 46539-20101109
ENGLISH
46539
CONTROLS ANd fEATuRES
Wireless Remote Control
This generator is equipped with a wireless remote
control system for starting and stopping . The system
consists of (4) main components:
1 . Receiver Control Module (RCM)
2 . Wireless Remote
3 . Battery Switch
4 . Ignition Switch
The Remote Control functions are enabled when:
1 . The Ignition Switch is in the “ON” position, AND
2 . The Battery Switch is in the “ON” position .
The Remote Control functions are disabled if either of
the above conditions is not met .
To start the generator by Remote Control, press the
“START” button on the Remote one time . The engine
will attempt to start (6) times . The RCM controls
the Auto Choke during each attempt to start . If the
generator does not start, call Champion Customer Care
team for assistance at 1 (877) 338-0999 .
To stop the generator by Remote Control, press the
“STOP” button on the Remote one time .
Remote Control Power Consumption
While the Ignition Switch is in the “ON: position, the
RCM is active and waiting for a remote signal . This
function requires electrical current from the battery .
If the Ignition Switch is left in the “ON” position for
extended periods (several weeks), the battery can be
completely drained .
Moving the Ignition Switch to the “OFF” position
disables the Remote functions, but the RCM still
consumes approximately 2 mA from the battery .
To prevent battery drain, press the Battery Switch to the
“OFF” position . This disconnects power to the RCM so
there is no current draw on the battery .
Power Panel Load Management
When the generator initially starts by the Remote, no
voltage is supplied to the Power Panel for approximately
15 seconds . This allows the engine to reach full speed
before electrical loads are applied to the generator .
When the generator is stopped by the Remote, the
voltage to the Power Panel is immediately turned off .
Then the engine stops approximately 5 seconds after
the “STOP” button on the Remote is pressed . Turning
the Power Panel voltage off before the engine shutdown
protects connected appliances from being damaged by
non-60 Hz voltage while the generator coasts to a stop .
The on/off voltage delay at startup and shut down only
happen when the Remote Control is used. There is no
voltage delay when the pushbutton electric start or recoil
start method is used.
When the pushbutton electric start or recoil start
method is used, the operator must be sure all electrical
loads (appliances) are turned OFF during startup and
shutdown . Damage to the generator or the attached
appliances can be caused by starting or stopping the
generator while appliances are plugged in and turned ON .
vacuum fuel valve
This generator is equipped with a Vacuum Fuel Valve .
The Vac Fuel Valve functions similar to a standard on/
off fuel valve with the addition of a vacuum sensor that
can open and close the fuel valve based on whether the
engine is running or not .
The Vac Fuel valve has (3) selectable positions:
1. OFF
(pointing up)
a . Valve is switched CLOSED so no fuel passes
through the valve .
2. RUN
(pointing left)
a . Turns on the Vac feature of the valve . The valve
only opens to allow fuel to flow when the engine is
running which provides vac pressure to the valve .
b . Valve stays OPEN while engine is running .
c . Valve automatically CLOSES when the engine stops .
3. PRIME
(pointing down)
a . Valve is switched OPEN to allow fuel to flow
freely to the carburator .
Starting with a “dry fuel Line”
When there is no residual fuel in the carburetor, the
Vacuum Fuel Valve must be in the “PRIME” position in
order to start the generator . This case occurs when the
unit is:
– Brand new out of the box, OR
– The fuel line and carburetor have been drained for
long term storage .
When the engine starts and reaches full speed, the Vac
Fuel Valve can be turned to the “RUN” position .
Starting with a “Primed fuel Line”
When residual fuel is present in the fuel line and
carburetor, the Vacuum Fuel Valve may be turned to the
“PRIME” or “RUN” position to start the generator .
Power Panel Load Management Cont’d.
OFF
RUN
PRIME