17

  

REV 46539-20101109

ENGLISH

 

46539

MAINTENANCE ANd STORAGE

Generator Maintenance

Make certain that the generator is kept clean and stored 
properly . Only operate the unit on a flat, level surface in 
a clean, dry operating environment . DO NOT expose the 
unit to extreme conditions, excessive dust, dirt, moisture 
or corrosive vapors .

Storage

The generator should be started at least once every 14 
days and allowed to run for at least 20 minutes . For 
longer term storage, please follow these guidelines .

Generator Storage

1 .  Allow the engine to cool completely before storage .
2 .  Clean the generator according to the instructions in 

the Maintenance section .

3 .  Turn the vac fuel valve to the “OFF” position .
4 .  Be sure all appliances are disconnected from the 

generator . Start the engine and let it run until the 
fuel in the line and the carburator is consumed and 
the engine dies .

5 .  Press the Battery Switch to “OFF” .
6 .  Add a fuel stabilizer into the fuel tank .
7 .  Change the oil .
8 .  Remove the spark plug and pour about ½ ounce 

of oil into the cylinder . Crank the engine slowly to 
distribute the oil and lubricate the cylinder .

9 .  Reattach the spark plug .
10 . Store the unit in a clean, dry place out of direct 

sunlight .

Use a damp cloth to clean exterior surfaces of the generator .
Use a soft bristle brush to remove dirt and oil .
Use an air compressor (25 PSI) to clear dirt and debris 
from the generator . 
Inspect all air vents and cooling slots to ensure that they 
are clean and unobstructed .

DO NOT use a garden hose to clean the generator .

Water can enter the generator through the cooling 
slots and damage the generator windings .

CAuTION

disconnect the Battery

1 .  Remove the protective cover from the black/negative 

battery lead .

2 .  Disconnect the black/negative lead from the black/

negative terminal on the battery and store the cap 
screw (M6x10) and lock washer (M6) .

3 .  Repeat steps 1-2 for the red/positive battery lead .
4 .  Store the battery in a cool, dry place .

Charge the Battery

For generators equipped with batteries for electric 
starting, proper battery maintenance and storage 
should be followed . An automatic battery charger with 
automatic trickle charging capability should be used to 
charge the battery . Maximum charging rate should not 
exceed 1 .5 amps . Follow the instructions included with 
the battery charger . The battery should be fully charged 
at least once per month .

Generator exhaust contains odorless and colorless 
carbon monoxide gas .

To avoid accidental or unintended ignition of your 
remote start generator during periods of storage, 
the following precautions should be followed:

 

– When 

storing the generator for short periods of

time

 make sure that the Ignition Switch, the Fuel

Valve and the Battery Switch are set in the 

OFF

 

position . 

 

– When 

storing the generator for extended periods 

of time

 make sure that the Ignition Switch, the 

Fuel Valve and the Battery Switch are set in the 
the the 

OFF

 position and the battery leads have 

been 

disconnected

 from the battery . 

dANGER

Содержание 46539

Страница 1: ...USA 1 877 338 0999 www championpowerequipment com 4000 Peak Watts 3500 Running Watts PORTABLE GENERATOR SAvE THESE INSTRuCTIONS Important Safety Instructions are included in this manual MADE IN CHINA...

Страница 2: ...he store WE ARE HERE TO HELP Visit our website www championpowerequipment com for more info Product Info Updates Frequently Asked Questions Tech Bulletins Product Registration or Call our Customer Car...

Страница 3: ...Remote 12 Connecting Electrical Loads 13 Stopping the Engine 13 Do Not Overload Generator 14 Capacity 14 Power Management 14 Wattage Reference Chart 14 Maintenance and Storage 15 Engine Maintenance 15...

Страница 4: ...rmation available when ordering parts and when making technical or warranty inquiries Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from you...

Страница 5: ...hazardous situation which if not avoided may result in minor or moderate injury CAUTION CAUTION used without the safety alert symbol indicates a potentially hazardous situation which if not avoided m...

Страница 6: ...nd remove jewelry Operate equipment with guards in place DO NOT wear loose fitting clothing dangling drawstrings or items that could become caught Generator produces powerful voltage DO NOT touch bare...

Страница 7: ...ull hand and arm towards the engine faster than you can let go Unintentional startup can result in entanglement traumatic amputation or laceration Broken bones fractures bruises or sprains could resul...

Страница 8: ...the engine No manual adjustment required 3 Vac Fuel Valve Turn this valve to the On position to supply fuel to the engine 4 Air Cleaner Protects the engine by filtering dust and debris from the intak...

Страница 9: ...ounding regulations 6 120V 30A Twist Lock Protected by a 25 Amp push to reset circuit breaker This receptacle powers 120 Volt AC 60 Hz single phase loads requiring up to 29 2 Amps or 3500 Watts of pow...

Страница 10: ...er the STOP button on the Remote is pressed Turning the Power Panel voltage off before the engine shutdown protects connected appliances from being damaged by non 60 Hz voltage while the generator coa...

Страница 11: ...lange Bolt M10x105 for Wheel 2 Flange Bolt M8x45 for Handle 2 Flange Bolt M8x25 for Vibration Mounts 2 Flange Bolt M8x16 for Support Leg 2 Nut M10 2 Flat Washer 10 2 Nut M8 6 Spark Arrester Kit Spark...

Страница 12: ...erything from the carton except the generator 3 Carefully cut each corner of the box from top to bottom Fold each side flat on the ground to provide a surface area to install the wheel kit and support...

Страница 13: ...cap screw M6x10 and secure with the lock washer M6 3 Repeat steps 1 2 for the black battery lead Install the Spark Arrester Insert the spark arrester screen into the muffler outlet Secure the spark ar...

Страница 14: ...tane rating of 85 Do not mix oil and gasoline Fill tank to approximately inch below the top of the tank to allow for fuel expansion DO NOT fill fuel tank indoors DO NOT fill fuel tank when the engine...

Страница 15: ...e fluctuation may impair the proper functioning of sensitive electronic equipment CAUTION Operation Starting the Engine without Remote 1 Make certain the generator is on a flat level surface 2 Turn of...

Страница 16: ...receptacles is turned off and the engine will stop after 5 seconds Connecting a generator to your electric utility company s power lines or to another power source may be against the law In addition...

Страница 17: ...epeat steps 5 6 for each additional item Never exceed the specified capacity when adding loads to the generator NOTE Operation Wattage Reference Chart Use the chart to determine approximate wattage re...

Страница 18: ...clean engine oil 5 Squeeze in a clean absorbent cloth to remove all excess oil 6 Place the filter in the assembly 7 Reattach the air filter cover and snap in place Spark Plugs 1 Remove the spark plug...

Страница 19: ...PSI to clear dirt and debris from the engine Every 8 hours or daily Check oil level Clean around air intake and muffler First 5 Hours Change oil Every 50 hours or every season Clean air filter Change...

Страница 20: ...nspect all air vents and cooling slots to ensure that they are clean and unobstructed DO NOT use a garden hose to clean the generator Water can enter the generator through the cooling slots and damage...

Страница 21: ...t interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and o...

Страница 22: ...19 REV 46539 20101109 ENGLISH 46539 Specifications Parts Diagram...

Страница 23: ...68 070014 01 Rollover Valve Hose 1 55 ST168FD 1070400 CARB Rollover Valve 1 56 GB819 M5 10 Screw M5 10 2 57 ST02FD 04120000 CARB Fuel Meter Assembly 1 58 ST188FD 1741002 C Handle Sheath 1 Part Number...

Страница 24: ...21 REV 46539 20101109 ENGLISH 46539 Specifications Engine Parts Diagram...

Страница 25: ...03 Separator 1 54 ST168FD 1090002 Air Cleaner Seal 1 55 ST168FD 1090004 CARB Air Cleaner Case Comp 1 56 ST160F 1130003 CPE Carburetor Packing No Asbestos 1 57 ST168F 1130001 LPG Carburetor Insulator 1...

Страница 26: ...23 REV 46539 20101109 ENGLISH 46539 Wiring Diagram Specifications...

Страница 27: ...Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly connected Check all connections Connected...

Страница 28: ...y to parts and or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the generator s limits modified installed improperly or connected incorr...

Страница 29: ...luding diagnosis parts and labor MANUFACTURER S EMISSION CONTROL SYSTEM WARRANTY COVERAGE This emission control system is warranted for two years subject to provisions set forth below If during the wa...

Страница 30: ...n such written instructions to the effect of repair or replace as necessary shall not reduce the ECS Warranty Period Any such part repaired or replaced under the ECS Warranty shall be warranted for th...

Страница 31: ...lities or to obtain warranty service please write or call the Customer service of Champion Power Equipment Inc Champion Power Equipment Inc ATTN Customer Service 10006 Santa Fe Springs Road Santa Fe S...

Отзывы: