Champion Power Equipment 41153 Скачать руководство пользователя страница 8

Safety Rules 

4  

Rev 

41153-20090618

 

 DANGER 

Fuel and fuel vapors are highly flammable and 
extremely explosive. 

Fire or explosion can cause severe burns or 
death.  

Unintentional startup can result in entanglement, 
traumatic amputation or laceration.  

When adding or removing fuel 

Turn the generator off and let it cool for at least 
two minutes before removing the fuel cap. 
Loosen the cap slowly to relieve pressure in the 
tank. 
Only fill or drain fuel outdoors in a well-ventilated 
area. 
DO NOT overfill the fuel tank. 
Always keep fuel away from sparks, open flames, 
pilot lights, heat and other sources of ignition. 
DO NOT light or smoke cigarettes. 

When starting the generator 

DO NOT attempt to start a damaged generator.  
Make certain that the gas cap, air filter, spark 
plug, fuel lines and exhaust system are properly 
in place. 
Allow spilled fuel to evaporate fully before 
attempting to start the engine. 
Make certain that the generator is resting firmly 
on level ground. 

When operating the generator: 

DO NOT move or tip the generator during 
operation. 
DO NOT tip the generator or allow fuel or oil to 
spill. 

When transporting or servicing the 

generator: 

Make certain that the fuel shutoff valve is in the 
off position and the fuel tank is empty. 
Disconnect the spark plug wire. 

When storing the generator: 

Store away from sparks, open flames, pilot lights, 
heat and other sources of ignition. 

 

 
 

 WARNING 

Rapid retraction of the starter cord will pull hand 
and arm towards the engine faster than you can 
let go. 

Unintentional startup can result in entanglement, 
traumatic amputation or laceration.  

Broken bones, fractures, bruises or sprains could 
result. 

When starting engine, pull the starter cord slowly 
until resistance is felt and then pull rapidly to 
avoid kickback. 
DO NOT start or stop the engine with electrical 
devices plugged in. 

 

 CAUTION 

Exceeding the generator’s running capacity can 
damage the generator and/or electrical devices 
connected to it 

DO NOT overload the generator. 
Start the generator and allow the engine to 
stabilize before connecting electrical loads. 
Connect electrical equipment in the off position, 
and then turn them on for operation.

 

Turn electrical equipment off and disconnect 
before stopping the generator.

 

DO NOT tamper with the governed speed. 

 

DO NOT modify the generator in any way.

 

 

 CAUTION  

Improper treatment or use of the generator can 
damage it, shorten its life and void your 
warranty. 

Use the generator only for intended uses.

 

Operate only on level surfaces.

 

DO NOT expose generator to excessive moisture, 
dust, or dirt.

 

DO NOT allow any material to block the cooling 
slots.

 

If connected devices overheat, turn them off and 
disconnect them from the generator.

 

DO NOT use the generator if:

 

 

Electrical output is lost

 

 

Equipment sparks, smokes or emits flames

 

 

Equipment vibrates excessively

 

 

Содержание 41153

Страница 1: ...41153 Rev 41153 20090618 10006 Santa Fe Springs Road Santa Fe Springs CA 90670 USA Made in China 6500 Peak Watts 5500 Running Watts PORTABLE GENERATOR Owner s Manual and Operating Instructions...

Страница 2: ......

Страница 3: ...ference Chart 13 Maintenance 14 Engine Maintenance 14 Oil 14 Spark Plugs 14 Air Filter 15 Cleaning 15 Adjustments 15 Maintenance Schedule 15 Generator Maintenance 15 Storage 16 Engine Storage 16 Gener...

Страница 4: ......

Страница 5: ...t Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from your purchase To find out more about our covers power cables and storm kits please visi...

Страница 6: ...minently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serio...

Страница 7: ...ting parts Tie up long hair and remove jewelry Operate equipment with guards in place DO NOT wear loose fitting clothing dangling drawstrings or items that could become caught DANGER Generator produce...

Страница 8: ...away from sparks open flames pilot lights heat and other sources of ignition WARNING Rapid retraction of the starter cord will pull hand and arm towards the engine faster than you can let go Unintent...

Страница 9: ...ity fuel tank 2 Fuel Valve Turn this valve to the On position to supply fuel to the engine 3 Choke Lever Used to start the engine 4 Air Cleaner Protects the engine by filtering dust and debris from th...

Страница 10: ...5 Amps or 3000 watts of power 5 120 240 V 25 A Twist Lock Protected by a 25 A double throw circuit breaker on each 120 Volt leg of the receptacle This receptacle powers 240 Volt AC 60 Hz single phase...

Страница 11: ...ur 41153 Gasoline Powered Generator ships with the following parts Wheel Kit 10 Solid Wheel 2 piece Axle Assembly 2 sets Support Leg 1 piece Vibration Mounts 2 piece Support Leg Hardware 1 set Battery...

Страница 12: ...install the wheel kit and support leg Install the Wheel Kit CAUTION The wheel kit is not intended for over the road use You will need the following tools to install the wheel kit 17 mm wrench OR adjus...

Страница 13: ...often during the break in period Refer to the Maintenance section for recommended service intervals NOTE The generator rotor has a sealed pre lubricated ball bearing that requires no additional lubri...

Страница 14: ...ult in electric shock A ground terminal connected to the frame of the generator has been provided on the power panel For remote grounding connect of a length of heavy gauge 12 AWG minimum copper wire...

Страница 15: ...our sensitive equipment Surge suppressors come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations 2 Obtain an Uninterruptible Power...

Страница 16: ...ting wattage of all devices identified in step 1 Add this number to the number calculated in step 2 Surge wattage is the extra burst of power needed to start some electric driven equipment Following t...

Страница 17: ...00 Water Heater 4000 Security System 180 AM FM Radio 300 Garage Door Opener 1 2 HP 500 600 Battery Charger 12V DC 110 Heating Cooling Air Conditioner 12000 BTU 1700 2500 Fan 300 600 Furnace Fan 1 3 HP...

Страница 18: ...the proper grade of oil for your operating environment 1 Remove the oil drain plug with a 12 mm socket and extension 2 Allow the oil to drain completely 3 Replace the drain plug 4 Remove oil fill cap...

Страница 19: ...cate the nearest Champion Power Equipment certified service dealer for your generator or engine maintenance needs Every 8 hours or daily Check oil level Clean around air intake and muffler First 5 Hou...

Страница 20: ...the fuel line and carburetor to prevent gum from forming 4 Add a fuel stabilizer into the fuel tank 5 Change the oil 6 Remove the spark plug and pour about ounce of oil into the cylinder Crank the eng...

Страница 21: ...6 5 US gallons 25 L Use regular unleaded gasoline with a minimum octane rating of 85 Oil Oil capacity is 1 16 qt 1 1 L Spark Plugs Your generator comes equipped with a long reach plug 19 mm Intermitt...

Страница 22: ...Specifications 18 Rev 41153 20090618 Parts Diagram...

Страница 23: ...8 Conduit 1 25 ST05FD 05215004 Build up 1 26 ST182FDE 1000000 G Engine 1 27 ST05FD 1151600 Cover 1 28 GB5789 M6 8 Flange Bolt M6 8 4 29 ST05FD 1152020 4CSA Rotor comp 1 30 GB96 10 Washer 10 1 31 GB724...

Страница 24: ...Uncork baffle 6 2 77 GB896 8 Uncork baffle 8 2 78 ST182FD 1742202 UC Handle underlay 2 79 27 001 Pin 2 80 GB5789 M8 35 Flange Bolt M8 35 2 81 GB96 8 24 3 Big washer 8 2 82 ST182FD 1742003 UC Straight...

Страница 25: ...Specifications Rev 41153 20090618 21 Wiring Diagram...

Страница 26: ...ower or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properl...

Страница 27: ...ole Installation Use and Maintenance This warranty will not apply to parts and or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the gene...

Страница 28: ...Notes 24 Rev 41153 20090618 Notes...

Отзывы: