Safety Rules  

Rev 41153-20090618

 

 

3

 

Safety Rules 

 

 WARNING 

Read this manual thoroughly before operating 
your generator. Failure to follow instructions 
could result in serious injury or death. 
 

 

 WARNING 

The engine exhaust from this product contains 
chemicals known to the state of California to 
cause cancer, birth defects, or other reproductive 
harm. 
 

 

 DANGER 

Generator exhaust contains carbon monoxide, a 
colorless, odorless, poison gas. Breathing carbon 
monoxide will cause nausea, dizziness, fainting or 
death.  If you start to feel dizzy or weak, get to 
fresh air immediately. 

Operate generator outdoors only in a well 
ventilated area 
DO NOT operate the generator inside any 
building, including garages, basements, 
crawlspaces and sheds, enclosure or 
compartment, including the generator 
compartment of a recreational vehicle. 
DO NOT allow exhaust fumes to enter a confined 
area through windows, doors, vents or other 
openings. 

DANGER CARBON MONOXIDE

, using a 

generator indoors 

CAN KILL YOU IN 

MINUTES.

 

 

 DANGER 

Rotating parts can entangle hands, feet, hair, 
clothing and/or accessories. 

Traumatic amputation or severe laceration can 
result. 

Keep hands and feet away from rotating parts. 

Tie up long hair and remove jewelry. 
Operate equipment with guards in place. 
DO NOT wear loose-fitting clothing, dangling 
drawstrings or items that could become caught. 

 

 DANGER 

Generator produces powerful voltage. 

DO NOT touch bare wires or receptacles. 
DO NOT use electrical cords that are worn, 
damaged or frayed. 
DO NOT operate generator in wet weather. 
DO NOT allow children or unqualified persons to 
operate or service the generator 
Use a ground fault circuit interrupter (GFCI) in 
damp areas and areas containing conductive 
material such as metal decking. 
Use approved transfer equipment to isolate 
generator from your electric utility and Notify 
your utility company before connecting your 
generator to your power system. 

 

 WARNING  

Sparks can result in fire or electrical shock. 

When servicing the generator: 

Disconnect the spark plug wire and place it 
where it cannot contact the plug. 
DO NOT check for spark with the plug removed. 
Use only approved spark plug testers. 

 

 WARNING 

Running engines produce heat. 
Severe burns can occur on contact. 
Combustible material can catch fire on contact. 

DO NOT touch hot surfaces. 
Avoid contact with hot exhaust gases. 
Allow equipment to cool before touching. 
Maintain at least three feet of clearance on all 
sides to ensure adequate cooling. 
Maintain at least five feet of clearance from 
combustible materials. 

 

Содержание 41153

Страница 1: ...41153 Rev 41153 20090618 10006 Santa Fe Springs Road Santa Fe Springs CA 90670 USA Made in China 6500 Peak Watts 5500 Running Watts PORTABLE GENERATOR Owner s Manual and Operating Instructions...

Страница 2: ......

Страница 3: ...ference Chart 13 Maintenance 14 Engine Maintenance 14 Oil 14 Spark Plugs 14 Air Filter 15 Cleaning 15 Adjustments 15 Maintenance Schedule 15 Generator Maintenance 15 Storage 16 Engine Storage 16 Gener...

Страница 4: ......

Страница 5: ...t Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from your purchase To find out more about our covers power cables and storm kits please visi...

Страница 6: ...minently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serio...

Страница 7: ...ting parts Tie up long hair and remove jewelry Operate equipment with guards in place DO NOT wear loose fitting clothing dangling drawstrings or items that could become caught DANGER Generator produce...

Страница 8: ...away from sparks open flames pilot lights heat and other sources of ignition WARNING Rapid retraction of the starter cord will pull hand and arm towards the engine faster than you can let go Unintent...

Страница 9: ...ity fuel tank 2 Fuel Valve Turn this valve to the On position to supply fuel to the engine 3 Choke Lever Used to start the engine 4 Air Cleaner Protects the engine by filtering dust and debris from th...

Страница 10: ...5 Amps or 3000 watts of power 5 120 240 V 25 A Twist Lock Protected by a 25 A double throw circuit breaker on each 120 Volt leg of the receptacle This receptacle powers 240 Volt AC 60 Hz single phase...

Страница 11: ...ur 41153 Gasoline Powered Generator ships with the following parts Wheel Kit 10 Solid Wheel 2 piece Axle Assembly 2 sets Support Leg 1 piece Vibration Mounts 2 piece Support Leg Hardware 1 set Battery...

Страница 12: ...install the wheel kit and support leg Install the Wheel Kit CAUTION The wheel kit is not intended for over the road use You will need the following tools to install the wheel kit 17 mm wrench OR adjus...

Страница 13: ...often during the break in period Refer to the Maintenance section for recommended service intervals NOTE The generator rotor has a sealed pre lubricated ball bearing that requires no additional lubri...

Страница 14: ...ult in electric shock A ground terminal connected to the frame of the generator has been provided on the power panel For remote grounding connect of a length of heavy gauge 12 AWG minimum copper wire...

Страница 15: ...our sensitive equipment Surge suppressors come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations 2 Obtain an Uninterruptible Power...

Страница 16: ...ting wattage of all devices identified in step 1 Add this number to the number calculated in step 2 Surge wattage is the extra burst of power needed to start some electric driven equipment Following t...

Страница 17: ...00 Water Heater 4000 Security System 180 AM FM Radio 300 Garage Door Opener 1 2 HP 500 600 Battery Charger 12V DC 110 Heating Cooling Air Conditioner 12000 BTU 1700 2500 Fan 300 600 Furnace Fan 1 3 HP...

Страница 18: ...the proper grade of oil for your operating environment 1 Remove the oil drain plug with a 12 mm socket and extension 2 Allow the oil to drain completely 3 Replace the drain plug 4 Remove oil fill cap...

Страница 19: ...cate the nearest Champion Power Equipment certified service dealer for your generator or engine maintenance needs Every 8 hours or daily Check oil level Clean around air intake and muffler First 5 Hou...

Страница 20: ...the fuel line and carburetor to prevent gum from forming 4 Add a fuel stabilizer into the fuel tank 5 Change the oil 6 Remove the spark plug and pour about ounce of oil into the cylinder Crank the eng...

Страница 21: ...6 5 US gallons 25 L Use regular unleaded gasoline with a minimum octane rating of 85 Oil Oil capacity is 1 16 qt 1 1 L Spark Plugs Your generator comes equipped with a long reach plug 19 mm Intermitt...

Страница 22: ...Specifications 18 Rev 41153 20090618 Parts Diagram...

Страница 23: ...8 Conduit 1 25 ST05FD 05215004 Build up 1 26 ST182FDE 1000000 G Engine 1 27 ST05FD 1151600 Cover 1 28 GB5789 M6 8 Flange Bolt M6 8 4 29 ST05FD 1152020 4CSA Rotor comp 1 30 GB96 10 Washer 10 1 31 GB724...

Страница 24: ...Uncork baffle 6 2 77 GB896 8 Uncork baffle 8 2 78 ST182FD 1742202 UC Handle underlay 2 79 27 001 Pin 2 80 GB5789 M8 35 Flange Bolt M8 35 2 81 GB96 8 24 3 Big washer 8 2 82 ST182FD 1742003 UC Straight...

Страница 25: ...Specifications Rev 41153 20090618 21 Wiring Diagram...

Страница 26: ...ower or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properl...

Страница 27: ...ole Installation Use and Maintenance This warranty will not apply to parts and or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the gene...