Champion Power Equipment 41153 Скачать руководство пользователя страница 19

  

Maintenance 

Rev 41153-20090618

 

 

15

 

Air Filter 

1.

 

Remove the snap-on cover holding the 
air filter to the assembly. 

2.

 

Remove the foam element.  

3.

 

Wash in liquid detergent and water. 
Squeeze thoroughly dry in a clean cloth. 

4.

 

Saturate in clean engine oil.  

5.

 

Squeeze in a clean, absorbent cloth to 
remove all excess oil. 

6.

 

Place the filter in the assembly. 

7.

 

Reattach the air filter cover and snap in 
place. 

Cleaning 

 CAUTION 

DO NOT spray engine with water. 

Water can contaminate the fuel system. 

 

Use a damp cloth to clean exterior surfaces 

of the engine. 
Use a soft bristle brush to remove dirt and 

oil. 

Use an air compressor (25 PSI) to clear dirt 
and debris from the engine. 

Adjustments 

The air-fuel mixture is not adjustable. 
Tampering with the governor can damage 

your generator and your electrical devices 

and will void your warranty. CPE 
recommends that you contact our service 

line at 1-877-338-0999 for all other service 
and/or adjustment needs. 

Maintenance Schedule 

Follow the service intervals indicated in the 

schedule below.  
Service your generator more frequently 

when operating in adverse conditions.  
Contact our help line at 1-877-338-0999 to 

locate the nearest Champion Power 

Equipment certified service dealer for your 
generator or engine maintenance needs. 

 

Every 8  hours or daily 

  

Check oil level 

  

Clean around air intake and muffler 

First 5 Hours 

  

Change oil 

First 10 hours 

  

Check/Adjust Valve Clearance * 

Every 50 hours or every season 

  

Clean air filter 

  

Change oil if operating under heavy load 
or in hot environments 

Every 100 hours or every season 

  

Change oil 

  

Clean/Adjust spark plug 

  

Check/Adjust valve clearance * 

  

Clean spark arrester 

  

Clean fuel tank and filter * 

Every 3 years 

 

Replace fuel line 

 

 

*  To be performed by knowledgeable, 

experienced owners or Champion Power 
Equipment certified service dealers 

 

Generator Maintenance 

Make certain that the generator is kept clean 
and stored properly. Only operate the unit 

on a flat, level surface in a clean, dry 
operating environment. DO NOT expose the 

unit to extreme conditions, excessive dust, 

dirt, moisture or corrosive vapors.  

 CAUTION 

DO NOT use a garden hose to clean the 
generator. 

Water can enter the generator through the 
cooling slots and damage the generator 
windings. 

 

Use a damp cloth to clean exterior surfaces 
of the generator. 

Use a soft bristle brush to remove dirt and 

oil. 
Use an air compressor (25 PSI) to clear dirt 

and debris from the generator.  
Inspect all air vents and cooling slots to 

ensure that they are clean and unobstructed. 

Содержание 41153

Страница 1: ...41153 Rev 41153 20090618 10006 Santa Fe Springs Road Santa Fe Springs CA 90670 USA Made in China 6500 Peak Watts 5500 Running Watts PORTABLE GENERATOR Owner s Manual and Operating Instructions...

Страница 2: ......

Страница 3: ...ference Chart 13 Maintenance 14 Engine Maintenance 14 Oil 14 Spark Plugs 14 Air Filter 15 Cleaning 15 Adjustments 15 Maintenance Schedule 15 Generator Maintenance 15 Storage 16 Engine Storage 16 Gener...

Страница 4: ......

Страница 5: ...t Accessories Champion Power Equipment manufactures and sells accessories designed to help you get the most from your purchase To find out more about our covers power cables and storm kits please visi...

Страница 6: ...minently hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a potentially hazardous situation which if not avoided could result in death or serio...

Страница 7: ...ting parts Tie up long hair and remove jewelry Operate equipment with guards in place DO NOT wear loose fitting clothing dangling drawstrings or items that could become caught DANGER Generator produce...

Страница 8: ...away from sparks open flames pilot lights heat and other sources of ignition WARNING Rapid retraction of the starter cord will pull hand and arm towards the engine faster than you can let go Unintent...

Страница 9: ...ity fuel tank 2 Fuel Valve Turn this valve to the On position to supply fuel to the engine 3 Choke Lever Used to start the engine 4 Air Cleaner Protects the engine by filtering dust and debris from th...

Страница 10: ...5 Amps or 3000 watts of power 5 120 240 V 25 A Twist Lock Protected by a 25 A double throw circuit breaker on each 120 Volt leg of the receptacle This receptacle powers 240 Volt AC 60 Hz single phase...

Страница 11: ...ur 41153 Gasoline Powered Generator ships with the following parts Wheel Kit 10 Solid Wheel 2 piece Axle Assembly 2 sets Support Leg 1 piece Vibration Mounts 2 piece Support Leg Hardware 1 set Battery...

Страница 12: ...install the wheel kit and support leg Install the Wheel Kit CAUTION The wheel kit is not intended for over the road use You will need the following tools to install the wheel kit 17 mm wrench OR adjus...

Страница 13: ...often during the break in period Refer to the Maintenance section for recommended service intervals NOTE The generator rotor has a sealed pre lubricated ball bearing that requires no additional lubri...

Страница 14: ...ult in electric shock A ground terminal connected to the frame of the generator has been provided on the power panel For remote grounding connect of a length of heavy gauge 12 AWG minimum copper wire...

Страница 15: ...our sensitive equipment Surge suppressors come in single or multi outlet styles They re designed to protect against virtually all short duration voltage fluctuations 2 Obtain an Uninterruptible Power...

Страница 16: ...ting wattage of all devices identified in step 1 Add this number to the number calculated in step 2 Surge wattage is the extra burst of power needed to start some electric driven equipment Following t...

Страница 17: ...00 Water Heater 4000 Security System 180 AM FM Radio 300 Garage Door Opener 1 2 HP 500 600 Battery Charger 12V DC 110 Heating Cooling Air Conditioner 12000 BTU 1700 2500 Fan 300 600 Furnace Fan 1 3 HP...

Страница 18: ...the proper grade of oil for your operating environment 1 Remove the oil drain plug with a 12 mm socket and extension 2 Allow the oil to drain completely 3 Replace the drain plug 4 Remove oil fill cap...

Страница 19: ...cate the nearest Champion Power Equipment certified service dealer for your generator or engine maintenance needs Every 8 hours or daily Check oil level Clean around air intake and muffler First 5 Hou...

Страница 20: ...the fuel line and carburetor to prevent gum from forming 4 Add a fuel stabilizer into the fuel tank 5 Change the oil 6 Remove the spark plug and pour about ounce of oil into the cylinder Crank the eng...

Страница 21: ...6 5 US gallons 25 L Use regular unleaded gasoline with a minimum octane rating of 85 Oil Oil capacity is 1 16 qt 1 1 L Spark Plugs Your generator comes equipped with a long reach plug 19 mm Intermitt...

Страница 22: ...Specifications 18 Rev 41153 20090618 Parts Diagram...

Страница 23: ...8 Conduit 1 25 ST05FD 05215004 Build up 1 26 ST182FDE 1000000 G Engine 1 27 ST05FD 1151600 Cover 1 28 GB5789 M6 8 Flange Bolt M6 8 4 29 ST05FD 1152020 4CSA Rotor comp 1 30 GB96 10 Washer 10 1 31 GB724...

Страница 24: ...Uncork baffle 6 2 77 GB896 8 Uncork baffle 8 2 78 ST182FD 1742202 UC Handle underlay 2 79 27 001 Pin 2 80 GB5789 M8 35 Flange Bolt M8 35 2 81 GB96 8 24 3 Big washer 8 2 82 ST182FD 1742003 UC Straight...

Страница 25: ...Specifications Rev 41153 20090618 21 Wiring Diagram...

Страница 26: ...ower or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properl...

Страница 27: ...ole Installation Use and Maintenance This warranty will not apply to parts and or labor if this generator is deemed to have been misused neglected involved in an accident abused loaded beyond the gene...

Страница 28: ...Notes 24 Rev 41153 20090618 Notes...

Отзывы: