18
100246
ENGLISH
SPECIfICATIONS
Engine Specifications
– Model
YF168FD-2-010
– Displacement
196cc
– Type
4-Stroke OHV
– Start Type
Recoil
Oil
Use 10W-30 automotive oil.
Oil capacity is up to 0.6 L (0.6 qt.).
DO NOT OVERFILL.
Please reference the following chart for recommended
oil types for use in the generator.
fuel
Fuel capacity is 3.4 gallon (13 L). Use regular unleaded
gasoline with a minimum octane rating of 85 and an
ethanol content of less than 10% by volume.
Generator Specifications
– Model
100246
– Running Wattage
2800 Watts
– Starting Wattage
4000 Watts
– AC Load
120/240 V
– Phase
Single
– Frequency
60 Hz
– Fuel Capacity
3.4 gallon (13 L)
– Gross Weight
110.2 lb. (50 kg)
– Net Weight
101.9 lb. (46.2 kg)
– Height
22.2 in. (56.5 cm)
– Width
23.9 in. (60.8 cm)
– Length
26.3 in. (66.7 cm)
Maintenance Valve Clearance
– Intake: 0.13 – 0.17 mm (0.005 – 0.007 in.)
– Exhaust: 0.18 – 0.22 mm (0.007 – 0.009 in.)
Note: Tech bulletin regarding the valve adjustment
procedure is on www.championpowerequipment.com.
Spark Plugs
OEM spark plug: NHSP F6RTC
Replacement spark plug: NGK BPR6ES or equivalent
Make certain the spark plug gap is 0.7 - 0.8 mm or
(0.028 - 0.031 in.).
An Important Message About Temperature
Your Champion Power Equipment product is designed
and rated for continuous operation at ambient
temperatures up to 40°C (104°F). When your product is
needed your product may be operated at temperatures
ranging from -15°C (5°F) to 50°C (122°F) for short
periods. If the product is exposed to temperatures
outside this range during storage, it should be brought
back within this range before operation. In any event,
the product must always be operated outdoors, in a
well-ventilated area and away from doors, windows and
other vents.
Weather will affect engine oil and engine
performance. Change the type of engine oil used
based on weather conditions to suit the engine
needs.
NOTE
Full Synthetic 5W-30
Degrees Celsiusº (Outside)
(Outside)
Degrees Fahrenheitº