background image

3

ENGLISH

 

100246

SAfETy RULES

Generator exhaust contains carbon monoxide, a 
colourless, odourless, poison gas. Breathing carbon 
monoxide will cause nausea, dizziness, fainting or 
death. If you start to feel dizzy or weak, get to fresh 
air immediately.

Operate generator outdoors only in a well ventilated 
area.
DO NOT operate the generator inside any building, 
including garages, basements, crawlspaces and 
sheds, enclosure or compartment, including the 
generator compartment of a recreational vehicle.
DO NOT allow exhaust fumes to enter a confined 
area through windows, doors, vents or other 
openings.
DANGER CARBON MONOXIDE: using a generator 
indoors

 CAN KILL YOU IN MINUTES.

DANGER

Rotating parts can entangle hands, feet, hair, 
clothing and/or accessories. 
Traumatic amputation or severe laceration can result.

Keep hands and feet away from rotating parts.
Tie up long hair and remove jewelry.
Operate equipment with guards in place.
DO NOT wear loose-fitting clothing, dangling 
drawstrings or items that could become caught.

DANGER

Generator produces powerful voltage.

DO NOT touch bare wires or receptacles.

DO NOT use electrical cords that are worn, damaged 

or frayed.

DO NOT operate generator in wet weather.

DO NOT allow children or unqualified persons to 

operate or service the generator

Use a ground fault circuit interrupter (GFCI) in damp 

areas and areas containing conductive material such 

as metal decking.

Use approved transfer equipment to isolate generator 

from your electric utility and notify your utility 

company before connecting your generator to your 

power system.

DANGER

Sparks can result in fire or electrical shock.

When servicing the generator:

Disconnect the spark plug wire and place it where it 

cannot contact the plug.

DO NOT check for spark with the plug removed.

Use only approved spark plug testers.

WARNING

Running engines produce heat. Severe burns can 

occur on contact. 

Combustible material can catch fire on contact.

DO NOT touch hot surfaces.

Avoid contact with hot exhaust gases.

Allow equipment to cool before touching.

Maintain at least 3 ft. (91.4 cm) of clearance on all 

sides to ensure adequate cooling.

Maintain at least 5 ft. (1.5 m) of clearance from 

combustible materials.

WARNING

Medical and Life Support Uses.

In case of emergency, call 911 immediately.
NEVER use this product to power life support 
devices or life support appliances.
NEVER use this product to power medical devices 
or medical appliances.
Inform your electricity provider immediately if you 
or anyone in your household depends on electrical 
equipment to live.
Inform your electrical provider immediately if a 
loss of power would cause you or anyone in your 
household to experience a medical emergency.

WARNING

Read this manual thoroughly before operating your 
generator. Failure to follow instructions could result 
in serious injury or death.

WARNING

Содержание 100246

Страница 1: ...Springs CA 90670 USA 1 877 338 0999 www championpowerequipment com PORTABLE GENERATOR SAVE THESE INSTRUCTIONS Important Safety Instructions are included in this manual MADE IN CHINA REV 100246 201602...

Страница 2: ...N IMPORTANT MESSAGE ABOUT TEMPERATURE Your Champion Power Equipment product is designed and rated for continuous operation at ambient temperatures up to 40 C 104 F When your product is needed your pro...

Страница 3: ...ting Electrical Loads 13 Stopping The Engine 13 Grounding 13 Do Not Overload Generator 13 Capacity 13 Power Management 13 Operation at High Altitude 14 Maintenance And Storage 15 Engine Maintenance 15...

Страница 4: ...the accuracy and completeness of the information in this manual and we reserve the right to change alter and or improve the product and this document at any time without prior notice Since CPE CET hi...

Страница 5: ...nformation The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment Follow all safety messages to avoid or reduce the risk of serious injury...

Страница 6: ...GFCI in damp areas and areas containing conductive material such as metal decking Use approved transfer equipment to isolate generator from your electric utility and notify your utility company befor...

Страница 7: ...nt in the off position and then turn them on for operation Turn electrical equipment off before stopping the generator DO NOT tamper with the governed speed DO NOT modify the generator in any way CAUT...

Страница 8: ...y If a label comes off or becomes hard to read contact Champion Power Equipment s customer service department for possible replacement A DANGER Carbon Monoxide Label B DANGER Flammable Gas Exhaust Lab...

Страница 9: ...gallon 13 L capacity fuel tank 2 Choke Lever Used to start the engine 3 Fuel Valve Turn this valve to the On position to supply fuel to the engine 4 Air Filter Protects the engine by filtering dust a...

Страница 10: ...tor 3 Circuit Breakers Protects the generator against electrical overload 4 Ground Terminal Consult an electrician for local grounding regulations 5 120 240V 20 Amp Twist Lock NEMA L14 20R May be used...

Страница 11: ...owered generator ships with the following parts Wheel Kit 8 in Wheel 20 3 cm 2 Pin Roll 16 x 10 x 97 for Wheel 2 R Shape Pin 2 Support Leg w Vibration Mounts 1 Flange Bolt M8x16 for Support Leg 2 Hand...

Страница 12: ...e wheel kit and support leg Install the Wheel Kit Install the Support Leg 1 Attach the support leg to the generator frame with flange bolt M8x16 and flange lock nuts M8 2 Tip the generator slowly so t...

Страница 13: ...ded oil type is 10W 30 automotive oil NOTE Synthetic oil may be used after the 5 hour initial break in period Using synthetic oil does not increase the recommended oil change interval Full synthetic 5...

Страница 14: ...cture s warranty It is advisable to always shut off the fuel supply run the engine to fuel starvation and drain the tank when the equipment is not in use for more than 30 days NOTE Add Fuel 1 Use clea...

Страница 15: ...t to start NOTE Generator Location NEVER operate the generator inside any building including garages basements crawlspaces and sheds enclosure or compartment including the generator compartment of a r...

Страница 16: ...tems running 3 Identify the highest starting wattage of all devices identified in step 1 Add this number to the number calculated in step 2 Surge wattage is the extra burst of power needed to start so...

Страница 17: ...ions are also available in the Technical Bulletin area of the Champion Power Equipment internet site The part number and recommended minimum altitude for the application of the high altitude carbureto...

Страница 18: ...lug 4 Remove oil fill cap dipstick to add oil 5 Add up to 0 6 L 0 6 qt of oil and replace oil fill cap dipstick DO NOT OVERFILL 6 Dispose of used oil at an approved waste management facility Spark Plu...

Страница 19: ...contaminate the fuel system Spark Arrester 1 Allow the engine to cool completely before servicing the spark arrester 2 Remove the two screws holding the cover plate which retains the end of the spark...

Страница 20: ...fuel valve to the Off position 5 Let the generator run until fuel starvation has stopped the engine This usually takes a few minutes 6 The generator needs to cool completely before cleaning and storag...

Страница 21: ...7 0 009 in Note Tech bulletin regarding the valve adjustment procedure is on www championpowerequipment com Spark Plugs OEM spark plug NHSP F6RTC Replacement spark plug NGK BPR6ES or equivalent Make c...

Страница 22: ...38 39 40 41 42 43 44 45 46 47 48 49 50 51 87 88 89 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 14 21 17 18 22 23 13 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 71 73 74 76 78 79 80 81 75...

Страница 23: ...7 x 1 1 45 24 070030 00 Hole Breather Tube 1 46 122 070014 02 Pipe Reversal Valve 670 mm 1 Part Number Description Qty 47 122 070100 07 Cap Fuel Tank 1 48 122 070300 03 Fuel Filter Fuel Tank 1 49 2 0...

Страница 24: ...6 27 29 30 32 35 37 38 12 40 41 42 43 44 46 47 21 22 23 24 31 34 36 39 53 52 45 51 50 49 55 56 57 58 54 60 62 61 63 65 66 67 68 69 70 71 72 74 25 75 1 93 94 95 92 91 90 97 78 79 80 82 83 84 85 86 87 8...

Страница 25: ...ange Bolt M8 32 6 48 23 091002 21 Seal Air Cleaner 1 49 23 110006 00 Rod Governor 1 50 21 110003 00 Arm Governor 1 Part Number Description Qty 51 1 6177 06 Flange Nut M6 3 52 21 110001 00 Shaft Govern...

Страница 26: ...In W L BLACK YELLOW BLUE Br W G B W BROWN IGNITION COIL SPARKING PLUG ENGINE BLOCK B EXW FW MW2 MW1 V L Y Y AVR Br VOLT METER OIL LEVEL SW CONTROL BOX BLOCK Y G Y G Y G Y EARTH TERMINAL G Y ENG SW B W...

Страница 27: ...oad and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly connected Check all connections Connected device i...

Страница 28: ...rical component Normal maintenance is not covered by this warranty and is not required to be performed at a facility or by a person authorized by CPE Other Exclusions This warranty excludes Cosmetic d...

Страница 29: ...rol system is warranted for two years subject to provisions set forth below If during the warranty period emission related part on your engine is defective in materials or workmanship the part will be...

Страница 30: ...ll be warranted for the remainder of the ECS Warranty Period c Any warranted emissions related part which is scheduled for replacement as required maintenance in the Owner s Manual shall be warranted...

Страница 31: ...eparator carbon canister canister mounting brackets carburetor purge port connector TO OBTAIN WARRANTY SERVICE You must take your CPE engine or the product on which it is installed along with your war...