![Champion Global Power Equipment 200987 Скачать руководство пользователя страница 35](http://html1.mh-extra.com/html/champion-global-power-equipment/200987/200987_operators-manual_2589030035.webp)
200987 - 4500W WIRELESS REMOTE START INVERTER GENERATOR
STORAGE
35
10. SLOWLY pull the recoil to rotate the engine to distribute and
lubricate the cylinder.
11. Re-install the spark plug and spark plug wire.
12. Re-install the maintenance cover.
13. Clean the generator according to
Cleaning the Generator
.
14. Store the generator in a cool, dry place out of direct sunlight.
Long Term Storage (more than 1 year)
For storage over 1 year, the gasoline tank and carburetor must be
completely drained of gasoline.
1. Be sure all appliances are disconnected from generator.
2. Place inverter on blocks to allow appropriate gasoline
container or pan to slide under inverter.
3. Remove the non recoil side maintenance cover by removing
the two screws with a phillips head screw driver (included).
4. Disconnect the battery by pulling the two halves of battery
connector apart.
5. Turn the EZ Start dial clockwise to the full “ON” position.
6. Using a flat head screwdriver, rotate drain screw
counterclockwise (3) full turns. Gasoline will drain through
clear tubing out underneath the inverter. Make sure draining
gasoline empties into an appropriate container.
7. When gasoline stops flowing from the clear tube, rotate drain
screw clockwise until tight. Properly dispose of the drained
gasoline according to local regulations or guidelines.
8. Turn the EZ Start dial to the “STOP” position.
9. Follow steps 8-12 according to Short Term Storage.
Removing from Storage
NOTICE
If the generator has been improperly stored for a period
longer than 30 days with ethanol blended gasoline in the
gasoline tank and/or carburetor, all fuel must be drained
and the carburetor must be thoroughly cleaned of ethanol
build up. This process involves technically advanced tasks.
For assistance please call our Technical Support Team at
1-877-338-0999.
If the gasoline tank and carburetor were properly emptied of all
ethanol blended gasoline prior to the generator being stored,
follow the below steps when removing from storage.
1. Be sure the EZ Start dial is in the “STOP” position.
2. Add gasoline to the generator according to
Add Fuel.
3. Move the EZ Start dial to the “ON” position.
4. After 5 minutes check the carburetor and air filter areas for
any leaking gasoline. If any leaks are found, the carburetor
will need to be disassembled and cleaned or replaced. If no
gasoline leaks are found, turn the EZ Start dial to the “STOP”
position.
5. Check engine oil level and add clean, fresh oil if needed. See
Oil Specifications
for proper oil type.
6. Check and clear air filter of any obstructions such as bugs or
cobwebs. If necessary, clean air filter according to
Cleaning
the Air Filter
.
7. If disconnected, connect the battery by pushing the two
halves of battery connector together tightly.
8. Start the generator according to
Starting the Engine
.