200987 - 4500W WIRELESS REMOTE START INVERTER GENERATOR
STORAGE
34
Adjusting the Governor
WARNING
Tampering with the factory set governor will void your
warranty.
The air-fuel mixture is not adjustable. Tampering with the governor
can damage your generator and your electrical devices and
will void your warranty. Contact our Technical Support Team at
1-877-338-0999 for all other service and/or adjustment needs.
Maintenance Schedule
Follow the service intervals indicated in the following maintenance
schedule.
Service your generator more frequently when operating in adverse
conditions.
Contact our Technical Support Team at 1-877-338-0999 to locate
the nearest CPE certified service dealer for your generator or
engine maintenance needs.
EVERY 8 HOURS OR PRIOR TO EACH USE
Check oil level
Clean around air intake and muffler
FIRST 5 HOURS (BREAK IN)
Change oil
EVERY 50 HOURS OR ANNUALLY
Clean air filter
Change oil if operating under heavy load or in hot
environments
EVERY 100 HOURS OR ANNUALLY
Change oil
Clean/adjust spark plug
Clean spark arrestor
Clean fuel valve filter*
EVERY 250 HOURS
Clean combustion chamber*
Check/adjust valve clearance*
EVERY 3 YEARS
Replace fuel line*
* To be performed by knowledgeable, experienced owners or CPE certified service
centers.
STORAGE
WARNING
To avoid accidental or unintended ignition of your generator
during periods of storage, the following precautions should be
followed:
–
When storing the generator make sure the EZ Start dial is
set to the “OFF” position.
Short Term Storage (up to 30 days)
Gasoline in the gasoline tank has a maximum shelf life of up to 1
year with the addition of properly formulated fuel stabilizers and
if stored in a cool, dry place. Gasoline in the carburetor, however,
may gum up and clog the carburetor if it isn’t used or drained
within 2-4 weeks.
If using the generator within 2 weeks, follow the steps according
to
Stopping the Engine
section.
1. If not using the generator for 2-4 weeks, begin by making
sure all appliances are disconnected from the generator.
2. Start the generator as instructed in
Starting the Engine
section.
3. Let the engine run until fuel starvation has stopped the
engine.
4. After the engine stops, turn the EZ Start dial
counterclockwise to the “STOP” position.
Mid Term Storage (30 days – 1 year)
Gasoline in the tank has a maximum shelf life of up to 1 year with
the addition of a properly formulated fuel stabilizer and stored in a
cool, dry place.
1. Be sure all appliances are disconnected from the generator.
2. Add a properly formulated fuel stabilizer to the gasoline tank.
3. Start engine by following directions in the
Starting the Engine
section.
4. Run the generator for 10 minutes so the treated gasoline
cycles through the fuel system and carburetor.
5. Let the engine run until fuel starvation has stopped the
engine.
6. After the engine stops, turn the EZ Start dial
counterclockwise to the “STOP” position.
7. After fuel has run out and the engine has stopped, allow the
engine to cool.
8. Remove the non recoil side maintenance cover by removing
the two screws with a phillips head screw driver (included).
9. Remove the spark plug and pour about a tablespoon of oil into
the cylinder.