100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR
OPERATION
21
8. RECOIL START: Pull the starter cord slowly until resistance is
felt and then pull rapidly.
9. Do not over-choke. Allow the engine to warm up several
seconds before gradually pushing the choke to the “RUN”
position.
NOTICE
Keep choke in “Choke” position for only 1 pull of the recoil
starter. After first pull, push choke in for up to the next 3
pulls of the recoil starter. Too much choke leads to sparkplug
fouling/engine flooding due to the lack of incoming air. This will
cause the engine not to start.
Propane (LPG)
1. Make certain the generator is on a flat, level surface.
2. Disconnect all electrical loads from the generator. Never start
or stop the generator with electrical devices plugged in or
turned on.
3. Open the fuel valve on the propane cylinder.
4. Turn the fuel selector switch to the “Vertical” position and
connect LPG hose.
5. Push the battery switch to the “ON” position.
6. Push the ignition switch to the “ON” position.
7. ELECTRIC START: Pull the choke to the “Choke” position.
8. Press and hold the ignition switch to the “START” position.
Release as the engine begins to start. If the engine fails to
start within five seconds, release the switch and wait at least
ten seconds before attempting to start the engine again.