100396 - 3400W DUAL FUEL ELECTRIC START INVERTER GENERATOR
MAINTENANCE
28
Cleaning the Spark Arrestor
1. Allow the engine to cool completely before servicing the spark
arrester.
2. Remove the two screws holding the cover plate which retains
the end of the spark arrester to the muffler.
3. Remove the spark arrester screen.
4. Carefully remove the carbon deposits from the spark arrester
screen with a wire brush.
5. Replace the spark arrester if it is damaged.
6. Position the spark arrester in the muffler and attach with the
two screws.
CAUTION
Failure to clean the spark arrestor will result in poor engine
performance.
Adjusting the Governor
WARNING
Tampering with the factory set governor will void your
warranty.
The air-fuel mixture is not adjustable. Tampering with the governor
can damage your generator and your electrical devices and
will void your warranty. Contact our Technical Support Team at
1-877-338-0999 for all other service and/or adjustment needs.
Generator battery
This product is equipped with an automatic battery charging
circuit. The battery will receive charging voltage when the engine
is running. The battery will maintain a proper charge if the unit
is used on a regular basis (about once every two weeks). If it is
used less frequently, the battery should be connected to a trickle
charger (included) or battery maintainer to keep the battery
properly charged. If the battery is not able to start the engine, it
can be started by manually pulling the engine recoil cord. If the
battery voltage is extremely low, the charging circuit may not be
able to re-charge the battery. In this case, the battery must be
connected to a standard automotive style battery charger for
re-charging before it can be used.
Disconnect the Battery
1. Remove the battery panel cover.
2. Remove the protective cover from the black/negative battery
lead.
3. Disconnect the black/negative lead from the black/negative
terminal on the battery and store the cap screw and nut.
4. Repeat steps 1-2 for the red/positive battery lead.
5. Store the battery in a cool, dry place.
Charge the Battery
For a generator equipped with batteries for electric starting,
proper battery maintenance and storage should be followed. An
automatic battery charger (included) with automatic charging
capability should be used to charge the battery. Maximum
charging rate should not exceed 1.5 amps. Follow the instructions
included with the battery charger. The battery should be fully
charged at least once per month.
NOTICE
A Float Charger will maintain the battery condition over long
storage periods.
Maintenance Schedule
Follow the service intervals indicated in the following maintenance
schedule.
Service your generator more frequently when operating in adverse
conditions.
Contact our Technical Support Team at 1-877-338-0999 to locate
the nearest CPE certified service dealer for your generator or
engine maintenance needs.
EVERY 8 HOURS OR PRIOR TO EACH USE
Check oil level
Clean around air intake and muffler
Check propane (LPG) hose for leaks