Chamberlain STAR1000 Скачать руководство пользователя страница 3

3

MAIN MENU

COMMAND

DESCRIPTION

LEARN MENU

LEARN DEVICE

Program a device to the receiver.

BLOCK LEARN DEVICE

Block program a range of devices to the receiver.

LEARN TO LOC #

Program a device to a 4-digit number location.

DELETE MENU

DELETE DEVICE

Delete a specified device that has been programmed to the receiver.

DELETE ALL DEVICES

Delete all programmed devices.

SUSPEND MENU

SUSPEND DEVICE

Temporarily disables the function of a specified device that has been 
programmed to the receiver.

SUSPEND ALL DEVICES

Temporarily disables the function of ALL devices programmed to the 
receiver.

UNSUSPEND DEVICE

Re-enable the function of a suspended device.

UNSUSPEND ALL DEVICES

Re-enable the function of ALL suspended devices.

QUERY MENU

LOC # USED

Displays a range of used locations starting from a specified location.

LOC # AVAILABLE

Displays a range of empty locations starting from a specified location.

LOC # SUSPENDED

Displays a range of suspended locations starting from a specified 
location.

SETTINGS

CHANGE PIN

Change the 6-digit PIN number for the receiver.

DEALER INFO

Display and edit the dealer 11-digit contact phone number.

FIRMWARE VERSION

Displays the current firmware version.

BEEP

Turn the audible feedback on or off.

MEMORY

DUPLICATE MEMORY

Creates a memory backup. A backup memory module must be 
installed.

RESTORE MEMORY

Restores a memory backup from a memory module. 

NOTE: 

Content of memory backup module will over-write any 

information already stored in the receiver memory.

RELAY

Sets the relay activation time from .25 to 1 second.

CONTRAST

Press Down or Up arrows to adjust LCD contrast.

LANGUAGE

Sets menu language: English (Default), Spanish, and French.

FACTORY DEFAULT

Reset receiver to factory default settings.

PROGRAMMING COMMANDS

The table below describes the commands used to program the receiver.

DIAGNOSTICS

The receiver emits a series of audible beeps to signal programming and 
error events. The table at right lists all of the events and their audible 
notifications. The  On/Off column indicates that the audible notification for 
the event may be disabled in the BEEP SETTINGS menu.

EVENT

AUDIBLE 
NOTIFICATIONS

ON/OFF

Key press

Single

YES

Successful Add

Double

Successful Delete

Triple

Successful Suspend

Double

Successful Unsuspend

Double

Master PIN entry error

Long

Programming error

Long

Location out of range

Long

Generic Success

Double

Generic Error

Long

Received unknown Tx

Slow

YES

Received known Tx

Double

YES

Received known suspended Tx

Long

YES

Содержание STAR1000

Страница 1: ... is compatible with HomeLink For programming or compatibility information visit www homelink com The receiver capacity is 1 000 devices and can be any combination of remote controls and wireless keyless entries The receiver is watertight according to IPX44 specification INSTALLATION 1 Select a convenient location near the operator to be controlled by the receiver within line of sight of the intend...

Страница 2: ... restricts access to authorized administrators only If you omit this step anyone will be able to program the receiver Upon initial power up the system firmware revision is displayed for 5 seconds followed by the LiftMaster logo When a key is pressed CREATE PIN is displayed 1 Press YES to create PIN If the PIN is lost you may request a reset code by pressing RESET 2 Enter a 6 digit PIN and press YE...

Страница 3: ...ERSION Displays the current firmware version BEEP Turn the audible feedback on or off MEMORY DUPLICATE MEMORY Creates a memory backup A backup memory module must be installed RESTORE MEMORY Restores a memory backup from a memory module NOTE Content of memory backup module will over write any information already stored in the receiver memory RELAY Sets the relay activation time from 25 to 1 second ...

Страница 4: ...SPECIFICATIONS System Capacity 1000 devices Supply Voltage 9 30 Volts AC 9 42 Volts DC Operating Current 50 mA Maximum Stand By Current 30 mA Maximum Surge Suppression 6 0 kV Min Operating Temp Range 40 C to 65 C 50 Rh 40 F to 149 F 50 Rh Storage and Shipping Temp Range 40 C to 85 C 50 Rh Frequency Security 2 0 Only 310 315 390 433 30 433 92 434 54 868 30 868 95 869 85 MHz Relay Contact Rating 1 a...

Страница 5: ...ssport et Passport Lite Ce récepteur est compatible avec HomeLink Pour information sur la compatibilité ou la programmation visitez www homelink com La capacité du récepteur est de 1 000 appareils et prend en charge n importe quelle combinaison de télécommandes et entrées sans clé et sans fil Le récepteur est étanche conformément à la spécification IPX44 INSTALLATION 1 Choisissez un endroit commod...

Страница 6: ...e qui sera en mesure de programmer le récepteur Lors de la mise sous tension initiale la version du micrologiciel du système s affichera pendant 5 secondes suivie du logo LiftMaster Quand vous appuyez sur une touche le message CREATE PIN Créer NIP 1 Appuyer sur YES Oui pour créer le code NIP Si vous perdez le code NIP vous pouvez demander un code de réinitialisation en appuyant sur RESET Réinitial...

Страница 7: ...rologiciel BIP Active ou désactive le signal sonore MÉMOIRE DUPLIQUER MÉMOIRE Crée une mémoire de secours Un module de mémoire de secours doit avoir été installé RESTAURER MÉMOIRE Restaure une sauvegarde de mémoire à partir d un module de mémoire REMARQUE Le contenu du module de mémoire de secours remplacera toute donnée déjà stockée dans la mémoire du récepteur RELAIS Définit le délai d activatio...

Страница 8: ...u système 1 000 appareils Tension de l alimentation 9 30 Volts C A 9 42 Volts C C Courant de fonctionnement 50 mA maximum Courant de veille 30 mA maximum Limite de surtension 6 0 kV Min Plage de températures de fonctionnement 40 C à 65 C à 50 HR 40 F à 149 F 50 HR Plage de températures pour le remisage et l expédition 40 C à 85 C à 50 HR Fréquence Sécurité 2 0 seulement 310 315 390 433 30 433 92 4...

Страница 9: ...port y Passport Lite de Security 2 0 Este receptor es compatible con HomeLink Para información de programacion o de compatibilidad visite www homelink com La capacidad del receptor es de 1 000 dispositivos y puede ser de cualquier combinación de controles remotos y entradas con llave digital inalámbrica El receptor es hermético de acuerdo con la especificación IPX44 INSTALACIÓN 1 Elija una ubicaci...

Страница 10: ...acceso para que puedan acceder solo los administradores autorizados Si omite este paso cualquier persona podrá programar el receptor Al encenderlo por primera vez se mostrará la revisión del firmware del sistema por 5 segundos seguido por el logotipo de LiftMaster Al presionar una tecla aparecerá la opción CREAR PIN 1 Presione SÍ para crear un PIN Si se pierde el PIN podrá solicitar un código pres...

Страница 11: ...dor VERSIÓN DEL FIRMWARE Muestra la versión actual del firmware BEEP Enciende o apaga las respuestas sonoras MEMORIA DUPLICAR MEMORIA Crea una memoria de reserva Se debe instalar un módulo de reserva de memoria REESTABLECER MEMORIA Restablece una reserva de memoria desde un módulo de memoria NOTA El contenido del módulo de reserva de memoria sobrescribirá cualquier información que esté almacenada ...

Страница 12: ... ocasionar un funcionamiento no deseado ESPECIFICACIONES Capacidad del sistema 1 000 dispositivos Voltaje de tensión 9 30 Voltios de CA 9 42 Voltios de CC Corriente en funcionamiento 50 mA máxima Corriente en stand by 30 mA máxima Supresión de sobretensión 6 0 kV Min Rango de temperatura en funcionamiento 40 C a 65 C a 50 Rh 40 F a 149 F a 50 Rh Rango de temperatura para almacenar y enviar 40 C a ...

Отзывы: