16
7.7.13c Password Change
1. Choose “
PS
” function and press “
P
” button.
2. “
00
” flashes in display.
3. Use “
+
” or “
–
” buttons to enter current password and press “
S
” button. Value
starts flashing.
4. Use “
+
” or “
–
” buttons to enter NEW password and press “
P
” button.
5. Changed password value remains on display for 2 seconds. Then display
changes to “
PS
“.
NOTE:
If wrong (current) password was entered, “00” will flash for 5 seconds and
change to “PS”. Password is not changed.
If password is lost, use Factory Default function (Fd) to go back to default settings.
All settings (apart from Radio Memory) will be deleted.
P
+
S
P
+
S
P
+
S
P
+
S
III
III
III
III
2 sec.
III
III
or
or
7. PROGRAMMING
7.7.13d Force Motors in Open and Close Directions
Force Motor in OPEN direction allows force adjustment on top of force set during
the Learning phase. Password must be entered to access this function.
Standard force (Default)
+15%
+30%
+50%
Motor Force in CLOSE direction
Force Motor in CLOSE direction allows force adjustment on top of force set during
the Learning phase. Password must be entered to access this function.
Standard force (Default)
+15%
+30%
+50%
Motor Speed in CLOSE direction
Motor Speed in CLOSE direction allows opening speed adjustment compared to the
speed set during Learning phase. Password must be entered to access this function.
Standard speed (Default)
+10%
+20%
+30%
+50%
-10%
-20%
7.7.13e Speed Motors in Open and Close Directions
Motor Speed in OPEN direction allows closing speed adjustment compared to the
speed set during Learning phase. Password must be entered to access this function.
Standard speed (Default)
+10%
+20%
+30%
+50%
-10%
-20%
7.7.13f Soft-Stop Speed
Soft-Stop Speed function allows adjustment of the Soft-Stop speed compared to
default values set during Learning phase. Soft-Stop speed is 50% of the standard
speed as per default setting. Standard speed change impacts the Soft-Stop speed.
Password must be entered to access this function.
Standard speed (Default)
-10%
-20%
-30%
-50%
+10%
+20%
7.8 Factory Default
7.9 Finish and Exit
Factory default function resets control board to the original factory set-ups. All set-
tings, including limit settings, will be erased. LED display will show “E0”. Program-
med remote controls will remain learned. If Remote control accessories need to be
erased refer to the respective Radio Controls Programming section of this manual.
To exit the programming phase and save all changes,
move to FE function and press “P” button. The control board will go into Stand-by
mode and is ready to work.
There are also other ways to exit the programming and save settings:
• Press and hold “P” button for 5 seconds
• Wait 3 minutes after the last changes in the programming for automatic exit
no reset (Default)
reset to the factory default settings
7. 10 Double Gate Application
Using the SYNC terminal on the Control Board, it is possible to synchronize with a
second sliding gate operator for double wing application. The Control Boards of the 2
operators must be programmed individually (Basic and Advanced settings). After the
programming is finished all the peripheral and radio accessories (IRs, Safety Edge, TX,
ect) shall be connected/programmed only on one unit, that will become the PRIMARY
unit. The PRIMARY unit will control the second unit by SYNC connection (SECONDA-
RY unit). The PRIMARY unit must be the operator on the gate with longer travel. If gate
leaves have equal width choose any of the operators to be the Primary unit.
Following devices can be connected to the PRIMARY unit and will have effect on the
SECONDARY unit as well:
Infrared Photocells, Safety Edge, Input Command (Key Switches, Emergency Stop But-
ton, etc.), Remote control (TX), Flashing light, Maglock/ E-lock, Special Contact (relay)
Motor Force in OPEN direction
Motor Speed in OPEN direction