14
Open – Close – Open
Open – Stop – Close – Stop – Open (Default)
Open – Stop – Close – Open
Partial opening
STOP (NC contact)
Open, to complete OPEN position. Additional Open command during
the opening will be ignored
Close, to complete CLOSE position. Additional Close command
during the closing will be ignored
Open – Stop – Open - Stop
Close – Stop – Close - Stop
Open, hold to run
Close, hold to run
1. Press and hold „
S
“ and „+“ buttons on the control board at the same time, until
the LED spot starts flashing.
2. Press and hold the desired free button on transmitter to program the Partial
Opening Mode.
3.
The LED spot turns off when the programming is finished. If there is a light
connected to SPEC contact it will flash once.
Programming Transmitter in Partial Opening
TTC not active (Default)
10 seconds
20 seconds
30 seconds
45 seconds
1 minute
1.5 minutes
2 minutes
3 minutes
5 minutes
7.7.6 Timer To Close
Timer to close (TTC) function enables automatic closing of the gate from a com-
plete OPEN position after a pre-set period of time. Minimum one pair of LiftMaster
Infrared Photocells (IR) has to be installed to monitor closing movement to enable
TTC operation. TTC will not work if IR are protecting opening movement only.
TTC will also work with activated partial opening. If TTC function is active, timer is
counting down, and the IR beams are interrupted, the TTC timer shall re-start.
2 seconds reversal and Stop
Reversal back up to the end limit position (Default)
During Closing movement, upon impact gate reverses up to Open
position. During Opening movement, upon impact gate reverses for
2 seconds and stops
7.7.7 Reversal Time after Impact
Reversal time after impact function defines reversal behaviour after obstacle obst
-
ruction during closing or opening movement. This reversal behaviour is valid both
for motor force detection and safety edge application.
1,5 m opening travel
2 m opening travel (default)
3 m opening travel
7.7.5 Partial Opening
Partial opening only gives you the ability to open active leaf to a pre-set value only.
NOTE:
Pd command will work starting from Close limit position and during closing
movement. If a Pd command is executed from a complete OPEN position, the gate
will close.
An Open or transmitter command will always override the Pd command.
7. PROGRAMMING
e-lock/mag-lock not installed (Default)
e-lock active for 1 second prior to Motor
start in Open direction
e-lock active for 2 seconds prior to Motor
start in Open direction
Magnetic lock, constantly active at gate CLOSED; constantly
inactive during OPEN and CLOSE movement, gate OPEN or STOP
position. Magnetic lock will be deactivated in Battery Back-up mode.
7.7.8 E-Lock / Mag-Lock Settings
E-Lock function defines e-lock/mag-lock behaviour.
24VDC – 500mA e-lock or mag-lock can be connected.
no flashing lamp installed (Default)
continuous 24V supply - for flashing lamp with own control board
(FLA1-LED)
interrupted 24V supply - for flashing lamp without own control board
7.7.9 Flashing Light Settings
Flashing Light function allows to select which type of Flashing Lamp is connected.
24VDC- max 500 mA Flashing lamp (FLA1-LED) can be connected.
7.7.9a Pre-Flashing
Pre-Flashing Function defines time interval of pre-flashing of the flashing lamp prior
to gate movement. Function not active if Flashing Lamp (FL) Function is set to “00”.
no pre-flashing (Default)
1 second
2 seconds
3 seconds
4 seconds
5 seconds
7.7.10 Special Contact Settings
Special Contact Function defines relay activation time. A 24V max 500mA relay can
be connected to manage other devices, e.g. courtesy light. The time set here will
also control countdown for myQ remote light.
no activation (Default)
15 seconds
30 seconds
45 seconds
1 minute
1.5 minutes
2 minutes
3 minutes
4 minutes
5 minutes