1.  Press and release the “learn” 

button on motor unit. The learn 
indicator light will glow steadily 
for 30 seconds.

2.  Within 30 seconds, enter a four 

digit personal identification 
number (PIN) of your choice on 
the keypad. Then press and 
hold the ENTER button.

3.  Release the button when the 

motor unit lights blink. It has 
learned the code. If light bulbs 
are not installed, two clicks will 
be heard.

To Add, Reprogram or Change a Keyless Entry PIN

NOTE:

 Your new Keyless Entry must be programmed to operate your garage door opener.

USING THE “LEARN”  BUTTON

To change an existing, known PIN

If the existing PIN is known, it may be changed by 
one person without using a ladder.

1.  Press the four buttons for the present PIN, then 

press and hold the # button.

   The opener light will blink twice. Release the # 

button.

2.  Press the new 4-digit PIN you have chosen, then 

press Enter.

The motor unit lights will blink once when the PIN 
has been learned.

Test by pressing the new PIN, then press Enter. The 
door should move.

To set a temporary PIN

You may authorize access by visitors or service 
people with a temporary 4-digit PIN. After a 
programmed number of hours or number of 
accesses, this temporary PIN expires and will no 
longer open the door. It can be used to 

close

 the 

door even after it has expired. To set a temporary 
PIN:

1.     Press the four buttons for your personal entry PIN 

(not the last temporary PIN), then press and hold 
the 

 button.

   The opener light will blink three times. Release the 

button.

2.  Press the temporary 4-digit PIN you have chosen, 

then press Enter.

  The opener light will blink four times.

3.  To set the number of 

hours

 this temporary PIN will 

work, press the number of hours (up to 255), then 
press 

.

OR

3.  To set the number of 

times

 this temporary PIN will 

work, press the number of times (up to 255), then 
press #.

The opener light will blink once when the temporary 
PIN has been learned.

Test by pressing the four buttons for the temporary 
PIN, then press Enter. The door should move. If the 
temporary PIN was set to a certain number of 
openings, remember that the test has used up one 
opening. To clear the temporary password, repeat 
steps 1-3, setting the number of hours or times to 0 
in step 3.

One Button Close:

 Opener can be closed by 

pressing only the ENTER button if the one button 
close feature has been activated. This feature has 
been activated at the factory. To activate or 
deactivate this feature press and hold buttons 1 and 
9 for 10 seconds. The keypad will blink twice when 
the one button close is active. The keypad will blink 
four times when one button close is deactivated.

Содержание Security+ PD300DM

Страница 1: ...er s Manual Please read this manual and the enclosed safety materials carefully Fasten the manual near the garage door after installation The door WILL NOT CLOSE unless the Protector System is connect...

Страница 2: ...all the trolley 8 Fasten the rail to the motor unit and install the idler pulley 9 Install the chain cable 10 Tighten the chain 11 Installation 11 26 Installation safety instructions 11 Determine the...

Страница 3: ...Preparing your garage door Before you begin Disable locks Remove any ropes connected to garage door Complete the following test to make sure your garage door is balanced and is not sticking or binding...

Страница 4: ...ng in your garage If so a support bracket and additional fastening hardware may be required Installation Step 10 Depending upon garage construction extension brackets or wood blocks may be needed to i...

Страница 5: ...ED CEILING Support bracket fastening hardware is required See page 16 Safety Reversing Sensor Header Wall Gap between floor and bottom of door must not exceed 1 4 6 mm Wall mounted Door Control Rail M...

Страница 6: ...er Bracket Idler Pulley U Bracket Trolley Chain Spreader Rail Center Back Sections Rail Front header Section Lighted Door Control Button SECURITY Keyless Entry The Protector System Your garage door op...

Страница 7: ...8 1 Trolley Threaded Shaft 1 Lock Washer 3 8 1 Lock Nut 1 4 20 2 Bolt 1 4 20x1 3 4 2 Drywall Anchors 2 Clevis Pin 5 16 x1 1 Lag Screw 5 16 18x1 7 8 2 Screw 6ABx1 1 4 2 Clevis Pin 5 16 x1 1 2 1 Self T...

Страница 8: ...about 4 3 4 12 cm from the far end 1 Remove the straight door arm and hanging bracket packaged inside the front rail and set aside for Installation Step 5 and 12 NOTE To prevent INJURY while unpacking...

Страница 9: ...cm of cable through the window Allow it to hang until Assembly Step 5 Remove the tape from the idler pulley The inside center should be pre greased If dry regrease to ensure proper operation Place the...

Страница 10: ...cap and onto pin notches until both pins are securely locked in place 3 With the trolley against the screwdriver dispense the remainder of the cable chain along the rail toward the motor unit into the...

Страница 11: ...N INSTRUCTIONS To reduce the risk of SEVERE INJURY or DEATH WARNING WARNING WARNING WARNING 1 READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS 2 Install garage door opener only on properly b...

Страница 12: ...r the top edge of the door NOTE If the total number of inches exceeds the height available in your garage use the maximum height possible or refer to page 13 for ceiling installation To prevent possib...

Страница 13: ...nting toward the ceiling Mark the vertical set of bracket holes Drill 3 16 pilot holes and fasten the bracket securely to a structural support with the hardware provided Lag Screw 5 16 9x1 5 8 HARDWAR...

Страница 14: ...you may re use the old header bracket with the two plastic spacers included in the hardware bag Place the spacers inside the bracket on each side of the rail as illustrated Position the opener on the...

Страница 15: ...enient for setting an ideal door to rail distance Remove foam packaging Raise the opener onto a stepladder You will need help at this point if the ladder is not tall enough Open the door all the way a...

Страница 16: ...line with the header bracket if the bracket is not centered above the door 7 Remove the 2x4 Operate the door manually If the door hits the rail raise the header bracket NOTE DO NOT connect power to o...

Страница 17: ...the Lighted Door Control Button securely with 6ABx1 1 2 screws If installing into drywall drill 5 32 holes and use the anchors provided 3 Run bell wire up wall and across ceiling to motor unit Use in...

Страница 18: ...he hole in the release arm of the outer trolley Adjust rope length so the handle is 6 feet 1 83 m above the floor Ensure that the rope and handle clear the tops of all vehicles to avoid entanglement S...

Страница 19: ...g cord Connect the black line wire to the screw on the brass terminal the white neutral wire to the screw on the silver terminal and the ground wire to the green ground screw The opener must be ground...

Страница 20: ...15 cm above the floor Either can be installed on the left or right of the door as long as the sun never shines directly into the receiving eye lens The mounting brackets are designed to clip onto the...

Страница 21: ...p hugging the back edge of the track as shown in Figure 1 If your door track will not support the bracket securely wall installation is recommended Wall installation Figure 2 3 Place the bracket again...

Страница 22: ...is required Loosen the sending eye wing nut and readjust aiming directly at the receiving eye Lock in place Loosen the receiving eye wing nut and adjust sensor until it receives the sender s beam Whe...

Страница 23: ...rectly below any structural support across the top of the door 3 Mark drill holes and install as follows depending on your door s construction Metal or light weight doors using a vertical angle iron b...

Страница 24: ...INUM STEEL DOORS WITH GLASS PANEL ETC NOT PROVIDED ONE PIECE DOORS Please read and comply with the warnings and reinforcement instructions on the previous page They apply to one piece doors also Cente...

Страница 25: ...are above holes in straight arm disconnect straight arm Cut about 6 15 cm from the solid end Reconnect to trolley with cut end down as shown Bring arm sections together Find two pairs of holes that l...

Страница 26: ...5 16 18 Lock Washers 5 16 Ring Fastener Straight Arm Bolts 5 16 18x7 8 Door Bracket Clevis Pin 5 16 x1 1 4 Curved Door Arm Press the Door Control push button The trolley will travel to the fully clos...

Страница 27: ...e as explained in Adjustment Step 2 If the door does not close completely Increase down travel Turn the down limit adjustment screw counterclockwise One turn equals 2 5 cm of travel If door still won...

Страница 28: ...ntrol clockwise Make small adjustments until the door completes a close cycle After each adjustment run the opener through a complete travel cycle Do not increase the force beyond the minimum amount r...

Страница 29: ...nd run the opener through 3 or 4 complete travel cycles to test adjustment If the unit continues to fail the Safety Reverse Test call for a trained door systems technician IMPORTANT SAFETY CHECK Test...

Страница 30: ...s restored after interruption when the opener is activated Light will also turn on when someone walks through the open garage door They will turn off automatically after 4 1 2 minutes Bulb size is A19...

Страница 31: ...prevent possible SERIOUS INJURY or DEATH from a falling garage door If possible use emergency release handle to disengage trolley ONLY when garage door is CLOSED Weak or broken springs or unbalanced d...

Страница 32: ...interference that may cause undesired operation To prevent possible SERIOUS INJURY or DEATH NEVER allow small children near batteries If battery is swallowed immediately notify doctor To reduce risk...

Страница 33: ...The need for occasional adjustment for the force and limit settings is normal Weather conditions in particular can affect door travel Refer to Adjustment Step 1 Adjust the UP and DOWN Travel Limits De...

Страница 34: ...together If motor unit activates replace door control If motor unit does not activate disconnect door control wires from motor unit Momentarily short across red and white terminals with jumper wire If...

Страница 35: ...u wish to operate your garage door 3 Release the button when the motor unit lights blink It has learned the code If light bulbs are not installed two clicks will be heard To Add or Reprogram a Hand he...

Страница 36: ...es and will no longer open the door It can be used to close the door even after it has expired To set a temporary PIN 1 Press the four buttons for your personal entry PIN not the last temporary PIN th...

Страница 37: ...0 3V2032 Lithium battery 4 29B137 Remote control visor clip 5 41A2828 Emergency release rope and handle assembly 6 41B4494 1 2 Conductor bell wire white and white red 7 41A5047 Door bracket w clevis p...

Страница 38: ...108D79 Lens 8 30B532 Capacitor 1 2 HP 9 12A373 Capacitor bracket 10 41A3150 Terminal block w screws 11 41D3058 Universal replacement motor bracket assembly Complete with Motor worm bracket bearing ass...

Страница 39: ...when it detects a person entering the garage Sensor can be easily deactivated when desired 3 Button Mini Remote Control with SECURITY With key ring and fastening strip 956D 940D 10 Foot 3 m Rail Exte...

Страница 40: ...are confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or rep...

Отзывы: