INSTALLATION STEP 6
Install the Door Control
Locate door control within sight of the door at a minimum height
of 1.5 m where small children cannot reach, and away from
moving parts of the door and door hardware. The installation
surface must be smooth and flat. If installing into drywall (Figure
1), drill 4 mm holes and use anchors provided. For pre-wired
installations (as in new home construction), it may be mounted to
a single gang box (Figure 2).
NOTE:
After installation, a green indicator light behind the cover
will indicate proper connection. If not lit, the Lock and Light
features will not function (reverse wires to correct).
1. Strip 11 mm of insulation from one end of bell wire and
connect to the two screw terminals on back of door control by
color: white wire to 2 and white/red wire to the 1 (Figure 3).
2.
Model 1215EM -
Lighted door control:
Remove the cover from
the Lighted Door Control. Fasten to wall with 6ABx1-1/2" self-
tapping screws (Figure 4).
Model 1225EM - Multi-function door control:
Remove white
cover by gently prying at slot in top of the cover with a small
flat head screwdriver. Fasten with 6ABx1-1/4" self-tapping
screws (drywall installation) or 6-32x1" machine screws (into
gang box) as follows:
• Drill and install bottom screw, allowing 3 mm to protrude
above wall surface.
• Position bottom of door control on screw head and slide
down to secure. Adjust screw for snug fit.
• Install top screw with care to avoid cracking plastic housing.
Do not overtighten.
• Insert bottom tabs and snap on cover.
3.
(Standard installation only)
Run bell wire up wall and across
ceiling to motor unit. Use insulated staples to secure wire in
several places. Do not pierce wire with a staple, creating a
short or open circuit.
4. Strip 11 mm of insulation from end of bell wire. Connect bell
wire to the quick-connect terminals as follows: white to white
and white/red to red (Figure 5).
NOTE:
When connecting multiple door controls to the opener,
twist same color wires together. Insert wires into quick-connect
holes: white to white and red/white to red.
5. Use tacks or staples to permanently attach entrapment warning
label to wall near door control, and manual release/safety
reverse test label in a prominent location on inside of garage
door.
WIRING INSTRUCTIONS FOR ACCESSORIES
The Protector System
®
: To opener terminals: White to White and
Black to grey.
Outside Keylock Accessory connections: To opener terminals:
Red/white to Red and White to White.
Bell Wire
Terminal
Screws
Bottom Mounting Hole
Top Mounting Hole
Lighted Door Control Button
6ABx1-1/2" Screw
Drywall
Anchors
Insulated
Staples
Multi-function (std installation)
6AB x 1-1/4" Screw
Multi-function (pre-wired)
6-32 x 1" Screw
HARDWARE SHOWN ACTUAL SIZE
Figure 3
DOOR CONTROL (BACK)
To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door
control.
• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a closing
garage door:
• Install door control within sight of garage door, out of reach
of children at a minimum height of 1.5 m, and away from ALL
moving parts of door.
• NEVER permit children to operate or play with door control
push buttons or remote control transmitters.
• Activate door ONLY when it can be seen clearly, is properly
adjusted, and there are no obstructions to door travel.
• ALWAYS keep garage door in sight until completely closed.
NEVER permit anyone to cross path of closing garage door.
22
To release or insert wire,
push in tab with screwdriver tip
Door Control
Connections
11 mm
Strip wire 11 mm
Red
Grey
White
Figure 2
To Replace
Insert Bottom Tabs First
PRE-WIRED
INSTALLATION
24 Volt
Bell Wire
LOCK
L GHT
LOCK
LIGHT
To Replace
Insert Bottom Tabs First
Figure 1
STANDARD
INSTALLATION
Single
Gang Box
Figure 5