Wall

Mounting Bracket

FINAL ASSEMBLY

1.  Double check all wiring connections.

2.  Slide the fixture assembly onto the mounting 

screws as shown on outer carton packaging. Make 

sure wires do not obstruct mounting screws (see 

Figure 4).

3.  Tighten decorative nuts removed in step 1 of In-

stallation section securely against fixture base.

4.  Caulk around fixture base with silicone weather 

sealant. 

IMPORTANT:

 Ensure that the drain hole 

at the bottom of the unit is not blocked.

5.  Install bulb. Do not exceed wattage rating on 

fixture label.

6.  If  applicable,  install  fixture  top  using  two 

decorative screws (see Figure 5).

7.  If applicable, remove nut below sensor and 

install fixture tail assembly (see Figure 6). Use 

the nut removed to secure the tail assembly.

Mounting Screw

Terminal Block Insulator

Decorative Nut

Terminal Block

From Fixture

From AC Source

WIRING

Connect the fixture wires to the terminal block 

according to diagram. Make sure all screws on 

terminal block are tightened securely and terminal 

block insulator is folded over terminal block.

 WARNING: Turn power off at circuit 

breaker or fuse. Place tape over circuit 

breaker switch and verify power is off at 

the fixture.

 WARNING: Risk of electric shock. 

Terminal block insulator must cover 

terminal block after wiring is complete.

Green/Yellow

Green/Yellow

Blue

Blue or Black

Brown

Red or Brown

Figure 3

Figure 4

IMPORTANT: Mounting bracket must be 

earthed. Attach earth wire to bracket at the 

earth screw. Tighten earth screw securely 

against earth wire.

Содержание Secure Home SH-9132AU

Страница 1: ...ly REQUIREMENTS The light control requires 230 volts AC If you want to use Manual Mode the control must be wired through a switch It is illegal for persons other than a licensed electricianorpersonauthorizedbylegislation to work on fixed wiring or other electrical installations Before installation record the model num ber listed inside the fixture Attach receipt in case of possible warranty issues...

Страница 2: ... mounted 1 8 meters 6 feet above the ground Do not use dimmer switches or timers with this fixture The sensor on this light fixture detects motion by the movement of heat across the coverage area However following are examples of objects that also produce heat and can cause the sensor to trigger Pools of Water Air Conditioners Dryer Vents Animals Heating Vents Automobile Traffic If you suspect tha...

Страница 3: ...rdrilltodrillintothewalltoprovide a suitable mounting for the screws Note Also drill a 6 mm deep pilot hole for the earth screw Bracket mounting screws are not included Use 4 mm dia 8G x 30 mm screws Care should be taken to avoid drilling or screwing into concealed electrical wiring For solid brick walls screws and masonry plugs should be used 6 Attachmountingbrackettowallwithaminimum of two screw...

Страница 4: ...nstall fixture tail assembly see Figure 6 Use the nut removed to secure the tail assembly Mounting Screw Terminal Block Insulator Decorative Nut Terminal Block From Fixture From AC Source WIRING Connect the fixture wires to the terminal block according to diagram Make sure all screws on terminalblockaretightenedsecurelyandterminal block insulator is folded over terminal block WARNING Turn power of...

Страница 5: ...hrough the coverage area noting where youarewhenthelightsturnon InTESTmode light will stay on for 5 seconds after motion has stopped and then turn off 4 If the fixture is equipped with a rotatable sensor see Figure 7 move the sensor head left or right to change the coverage area see Figure 8 Note Grasp the sensor only as shown and turn the entire sensor Any other method may damage the sensor Do no...

Страница 6: ...itymaycausefalsetriggering due to heat sources in the coverage area see Troubleshooting section 6 Set the amount of ON TIME you want the light to stay on after motion is detected 1 5 or 10 minutes The timer will reset as long as there is motion present Once motion has stopped the timer will time out after the selected amount of time 9 1 m 30 ft 1 8 m 6 ft Maximum Maximum Range Coverage Angle Side ...

Страница 7: ...urn light switch on 2 Check bulb and replace if necessary 3 Replace fuse or turn circuit breaker on 4 Recheck after dark 5 Verify wiring is correct Light comes on in daylight 1 Light control may be installed in a relatively dark location 2 Light control is in TEST 1 The fixture is operating normally under these conditions 2 Set ON TIME switch to 1 5 or 10 minutes Light comes on for no apparent rea...

Страница 8: ... or return the Unit to you Exclusions This Chamberlain Limited Warranty does not cover any failure of or defect in the Unit due to 1 non compliance with the instructions regarding installation operation maintenance and testing of the Unit or of any product with which the Unit is used 2 any attempt by a person other than an authorised installer to repair dismantle reinstall or move the Unit to anot...

Отзывы: