Entry Codes
Page 7 of 8
Doc 6001050, Rev E
Notes:
Relay Codes:
1 = Cycle Relay 1
2 = Cycle Relay 2
3 = Cycles Both Relays
4 = Release Both Relays
5 = Toggle Relay 1
6 = Toggle Relay 2
7 = Toggle Both Relays
Cycle Relay:
When someone enters a valid entry code, the relay will
energize for a set period of time (see page 5), then de-energize
(deactivate to re-lock the door). If the relay is normally energized, then
it will de-energize for the set time and then re-energize.
Release Relay:
Returns relay action to default setting. If a relay is
toggled to stay energized (door is unlocked), releasing the relay will
de-energize it (door becomes locked).
Toggle Relay:
Energizes a de-energized relay (or de-energizes an
energized relay) until released or toggled.
Enter Timer Code “1” if you want an entry code to be restricted during the specified time.
Enter Timer Code “0” if you do not want an entry code to be restricted.
Deleting an Entry Code
1.
2. Entry Code (4 or 5 digits)
3.
Examples:
6 + 1234 + #
Deletes entry code “1234”.
Deleting ALL Entry Codes
This programming step will delete all the entry codes from the unit’s memory.
Important:
Once you delete the codes, you cannot retrieve them.
1.
2.
3.