![Chamberlain LiftMaster Professional SW420 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/chamberlain/liftmaster-professional-sw420/liftmaster-professional-sw420_owners-manual_2587522034.webp)
STOP/RESET
CONTROL INPUT (N.C.)
RESIDENTIAL RADIO
(SINGLE BUTTON) INPUT (N.O.)
HARD CLOSE
CONTROL INPUT (N.O.)
SHADOW LOOP
INPUT (N.O.)
SOFT OPEN
INPUT (N.O.)
HARD OPEN
CONTROL INPUT (N.O.)
INTERRUPT (SAFETY)
LOOP INPUT (N.O.)
OBSTRUCTION CLOSE
EDGE/PHOTO EYE INPUT (N.O.)
GL Board
NOTE:
SEE WIRING DIAGRAMS SHIPPED WITH KIT
FOR ADDITIONAL INFORMATION. SEE OWNERS
MANUAL FOR WIRING DISTANCES AND WIRE GAUGE
INFORMATION.
WARNING:
All controls that are to be used to
operate the gate system, MUST be installed
where the user cannot come into contact with the
gate while operating the controls. Also, always
install the controls where the user has full view of
gate operation.
* All inputs are normally open and momentary,
except the stop (N.C.). The following instructions
are based upon UL325, and include
recommendations for significant increase in
safety.
* We strongly recommend that you follow the UL
guidelines presented throughout the manual.
Installation device instructions - always follow the
instructions provided by the manufacturer when
installing and adjusting any control device. If
these instructions are contrary to the advice given
here, call for assistance.
OBSTRUCTION OPEN
EDGE/PHOTO EYE INPUT (N.O.)
24 Vac
1 2 3 4 5 6 7 8 9 10
11
12
13 14 15 16
J1 TERMINAL BLOCK
Field Wiring Terminal Blocks
5 8 9 10
11
12
R1 R2 R3 R4 3 5
SW420
Operator
3
3
6
6
9
9
#
#
2
2
5
5
8
8
0
0
1
1
7
7
OPEN
CLOS
E
STO
P
OPEN
CLO
SE
ST
OP
OPEN
CLO
SE
STOP
FRE
Q
FRE
Q
C O N T R O L C O N N E C T I O N D I A G R A M S