Master or Standalone 
Gate Setting

PROGRAM SETTINGS (DIP SWITCH S2)

EDGE/PHOTO OPEN

This switch (S2-3) selects edge or photoelectric sensor for 
the gate opening protection input. 

Open Photo Eye (Pause): 

When the controller is configured 

for photo eyes, the input functions to pause the gate during 
the opening cycle. Once the input is cleared the gate 
continues to open.

Open Edge:

 When the controller is configured for safety 

edges, the input functions to reverse the gate to the close 
limit when the edge is activated during the opening cycle. 

EDGE/PHOTO CLOSE

This switch (S2-4) selects edge or photo sensor for the gate 
closing protection input.

Close Photo Eye (Reverse): 

When the controller is 

configured for photo eyes, the input functions to reverse the 
gate to the open limit when activated during the close cycle. 

NOTE:

 Timer-to-Close will reset if enabled.

Close Edge: 

When the controller is configured for safety 

edges, the input functions to reverse the gate to the open 
limit when activated during the close cycle. The entrapment 
is not cleared at the limit and the Timer-to-Close will be 
disabled. The Timer-to-Close may be enabled by activating 
the interrupt loop, soft open or hard open input.

MASTER/SECOND SYSTEMS

Dual Gate Communications

The control board is capable of running the operator in a master 
or second mode depending on (S4) switch setting.

Before initiating any command the master unit queries for the 
presence of a “second unit” for a time period of one second. If 
the master gets no response the operator will operate in a stand 
alone mode. 

NOTE:

 For single unit applications, a jumper must be 

placed between 11 and 12 of the field wiring terminal block. In 
this mode no further communications will take place during 
travel. If the master detects the presence of a second unit the 
master will continue to query the second unit during travel. The 
second unit will send a response to the master for every query. 
The second operator will stop if there is a period of one second 
or more of no communications. 

ON 

CLED                    PH 

OPED                   PH 

1     2     3    4 

WA

R

N

 

MAG 

ON 

S2 

ON 

CLED                    PH 

OPED                   PH 

1     2     3    4 

W

ARN 

MAG 

ON 

S2 

ON 

CLED                    PH 

OPED                   PH 

1     2     3    4 

WA

R

N

 

MAG 

ON 

S2 

ON 

CLED                    PH 

OPED                   PH 

1     2     3    4 

WA

R

N

 

MAG 

ON 

S2 

Master 

Unit

S4

S4

Second Gate 
Setting

Master 

Unit

TRAFFIC

Earth Ground Rod 

(One Side Only)

Terminal 
Block

Terminal 

Block

Shielded Cable 

(twisted pair)

minimum 18 gauge

Conduit

STREET

COMPLEX 

OR 

PARKING LOT

SAMS 
Conduit

Second

Second 

Unit

Second 

Unit

ON

ON

When two operators are connected in dual gate configuration 
accessories may be connected to either the master or second.

NOTE:

 Do not run Master/Second communication wiring in the 

same conduit as the power and control wiring. The Second unit 
will require a normally close stop circuit for proper system 
operation. After Master/Second wiring has been completed and 
the S4 switch programmed, both units must have their power 
cycled to initiate proper Master/Second communication. The 
motor learn function must be completed in stand alone mode 
prior to Master/Second wiring.

Hold Open Loop

Shadow Loop

Safety Loop

Содержание LiftMaster Professional SW420

Страница 1: ...DED FOR PROFESSIONAL INSTALLATION ONLY VISIT WWW LIFTMASTER COM TO LOCATE A PROFESSIONAL INSTALLING DEALER IN YOUR AREA THIS MANUAL IS TO BE LEFT WITH THE PROPERTY OWNER MODEL SW420 LIGHT DUTY SWING GATE OPERATOR Serial _________________________ located on electrical box cover Installation Date__________________ 2 YEAR WARRANTY ...

Страница 2: ...d to highlight certain safety related issues These instructions are not intended to be comprehensive Because each application is unique it is the responsibility of the purchaser designer installer and end user to ensure that the total gate system is safe for its intended use CARTON INVENTORY Before beginning your installation check that all components were supplied and received undamaged Refer to ...

Страница 3: ...r Maximum Gate Starts 10 hr Maximum Gate Weight 300 lbs 136 1 kg Maximum Gate Width 12 ft 3 7 m 11 5 8 18 3 16 1 3 8 1 3 8 1 3 8 14 5 8 11 5 8 3 3 16 3 3 16 11 5 8 3 3 16 1 1 2 5 8 18 3 16 18 3 16 11 3 4 11 3 4 3 Nominal Post Mount standard Pad Mount optional Pedestal Mount optional 12 Max 3 3 16 ...

Страница 4: ...nd one independent secondary means of entrapment protection Both primary and secondary entrapment protection methods must be designed arranged or configured to protect against entrapments in both the open and close directions of gate travel For Example For a slide gate system that is installed on a single family residence UL325 Class I you must provide the following As your primary type of entrapm...

Страница 5: ...oto eye for close cycle Shadow Loop Shadow Loop Photo eye for close cycle Run twisted wire from loop to operator Run twisted wire from loop to operator Seal Loops Seal Loops Gate 2 1 1 2 37 mm 1 1 2 37 mm 1 4 6 mm or larger depending on loop wire size 1 4 6 mm or larger depending on loop wire size Loop Wire Layer COMPLEX OR PARKING LOT COMPLEX OR PARKING LOT Interrupt Safety Loop Interrupt Safety ...

Страница 6: ...t be located at least six feet 6 away from any moving part of the gate and where the user is prevented from reaching over under around or through the gate to operate the controls Outdoor or easily accessible controls shall have a security feature to prevent unauthorized use 9 The Stop and or Reset if provided separately must be located in the line of sight of the gate Activation of the reset contr...

Страница 7: ...ionary object nearest the roadway such as a gate support post and the gate frame when the gate is in either the fully open position or the fully closed position shall not exceed 2 1 4 inches 57 mm refer to ASTM F2200 for Exception 3 1 4 Positive stops shall be required to limit travel to the designed fully open and fully closed positions These stops shall be installed at either the top of the gate...

Страница 8: ...ERTISSEMENT WARNING WARNING CAUTION WARNING WARNING To prevent SERIOUS INJURY or DEATH from a moving gate Entrapment protection devices MUST be installed to protect anyone who may come near a moving gate Locate entrapment protection devices to protect in BOTH the open and close gate cycles Locate entrapment protection devices to protect between moving gate and RIGID objects such as posts A swingin...

Страница 9: ...se the 2 sets of holes nearest to the rear side of the cabinet If mentioned holes are used the upper rear holes are larger than the other holes This is because a special nut is required for the U bolt in these holes due to an inaccessibility of tools inside the cabinet in the area of these holes 4 Insert the U bolt nut through the cabinet wall from the inside and onto the leg of the U bolt This nu...

Страница 10: ... hardware provided 5 Secure the operator to the concrete pad It is very important that the operator be level and square to the gate Figure 1 Figure 2 I N S T A L L A T I O N 26 3 4 14 3 4 19 19 6 6 Gate Pivot Gate Pivot Fence Line Fence Line 1 2 Concrete Anchor Bolts Parallel Mount Perpendicular Mount 6 1 2 18 1 2 18 x30 Pad Minimum 1 2 12 7 mm Concrete Anchors 4 Required Depth Required By Local C...

Страница 11: ...the pedestal by dropping it onto the pedestal and allowing the mounting studs to slip through the holes on the pedestal brackets Secure with hex nuts provided Figure 1 Figure 2 I N S T A L L A T I O N 26 14 26 14 Fence Line Hinge Pin Pivot Gate Fence Line Hinge Pin Pivot Gate Parallel Mount Pedestal 24 Deep In Ground Minimum Power and Control Wiring Should Be Run In Separate Conduit Pedestal Mount...

Страница 12: ...fully closed position and extend the arm assembly out to the closed gate Mark the point on the gate where the gate bracket will mount to the gate 8 The gate bracket must be installed on a structural member of the gate If require install a horizontal support on the gate at the appropriate height 9 Attach the gate bracket with U bolts or by welding Figure 2 Figure 1 I N S T A L L A T I O N If the ar...

Страница 13: ...he hairpin cotter and then the clevis pin and allowing the manual release pin to drop down through the hub The arm should now be free and the gate can be opened and closed normally NOTE If desired a padlock can be used in place of the clevis pin to hold the manual release pin in place Figure 1 I N S T A L L A T I O N Drive Hub Control Arm Clevis Pin Hairpin Cotter Release Pin ...

Страница 14: ...UST be made by a qualified individual DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram We recommend that you Install an optional reversing edge BEFORE proceeding with the control station installation ALL power wiring should be on a dedicated circuit and well protected The location of the power disconnect should be visible and clearly labeled ALL power ...

Страница 15: ... and is to be wired within line of sight of the gate The operator will not function unless this circuit is completed 2 Wire control station to terminals 3 and 5 in the control box on the operator FIELD WIRING TERMINALS STOP RESET Button Control Conduit STOP RESET STOP RESET BUTTON WIRING R1 R2 R3 R4 3 5 W I R I N G SINGLE PHASE All single phase operators will have the following 115V 208 230V L1 NE...

Страница 16: ...e control codes Press and hold the learn button on the receiver panel until the indicator light turns off about 6 seconds All remote control codes are now erased Then follow the steps above to reprogram each remote control M M NOTICE To comply with FCC and or Industry Canada IC rules adjustment or modifications of this receiver and or transmitter are prohibited except for changing the code setting...

Страница 17: ...TCH 8 Turn on power Press OPEN button if installed or connect terminals 5 7 on J1 terminal strip Gate should open If gate does not open the open limit cam may be already actuating open limit switch or an improper electrical connection may have been made Turn off power inspect correct and repeat this step 9 When gate reaches desired fully open position press STOP button or release terminals Turn of...

Страница 18: ... the hall bracket to the frame 2 Adjust the bracket so that the sensor is a Parallel with the pulley b 020 051 cm away from the pulley s magnet Use a feeler gauge to measure the distance 3 Tighten screws to secure assembly 4 Manually rotate pulley to ensure that each magnet clears the sensor board If a magnet does not clear the board re adjust the RPM hall effect assembly accordingly A D J U S T M...

Страница 19: ...Use a timer to close system to automatically close the barrier gate after a preset amount of time or b Use a loop system to close the barrier gate after the vehicle has passed through the SAM system 4 Once the barrier gate is closed the slide or swing gate will activate its internal timer to close and begin closing 5 If another authorized vehicle accesses the SAM system before the slide or swing b...

Страница 20: ... the open limit J1 Terminals 2 5 Shadow Loop Input These terminals are intended for use with a loop detector and is primarily used on swing gate operators This input protects cars by preventing the gate from moving off of the open or close limit when the shadow loop input is active J1 Terminals 6 5 Soft Open These terminals are intended for use as a general open control Accessories that may be wir...

Страница 21: ...reset button or the stop control of a three button station that is installed within line of site of the gate This input functions to stop the gate or to reset the gate after an entrapment fault NOTE This input uses a normally closed circuit and the operator will not run until a stop control is installed J1 Terminals 4 5 Hard Close Control Input These terminals are intended for use only with the cl...

Страница 22: ...LEDs J5 Connector SAMS J2 Connector J3 Connector Aux Relay Drive not used Motor Learn Button Programming Port factory use only Limit LEDs Main Terminal Wiring Potentiometer Timer to Close Dip Switch 4 Master Second J4 Connector Master Second Diagnostic LED Dip Switch 2 Dip Switch 1 Potentiometer Force Adjustment ...

Страница 23: ... cycle of gate travel but can be reversed off an obstruction without applying an unreasonable amount of force On most operators this will be around the middle of the range NOTE For LED location refer to illustration on previous page DIAGNOSTICS LEDS AND CODES There are three diagnostic LEDs Two red LEDs OLS CLS are indicators for the open and close limits The LEDs are illuminated when the limit sw...

Страница 24: ...LEDS There are 9 troubleshooting LEDs LED LED NAME DESCRIPTION D11 Radio On when Radio switch is activated D13 Shadow On when Shadow Loop is activated D15 Hard Close On when Close switch is activated D17 Green Stop On when Stop switch is not activated D19 Soft Open On when Open switch is activated D21 Hard Open On when Open switch is activated D24 Interrupt Safety Loop On when Interrupt Safety Loo...

Страница 25: ...1 2 3 4 ON SAVE TTC ON S1 RT LT SW SL APEMs ON CLED PH OPED PH 1 2 3 4 WARN MAG ON S2 ON CLED PH OPED PH 1 2 3 4 WARN MAG ON S2 ON CLED PH OPED PH 1 2 3 4 WARN MAG ON S2 ON CLED PH OPED PH 1 2 3 4 WARN MAG ON S2 1 2 3 4 ON SAVE TTC ON S1 1 2 3 4 ON SAVE TTC ON S1 RT LT SW SL RT LT SW SL PROGRAM SETTINGS DIP SWITCH S1 NOTE For all S1 S2 and S4 switch settings to take effect the Save Mode switch mus...

Страница 26: ...ence of a second unit for a time period of one second If the master gets no response the operator will operate in a stand alone mode NOTE For single unit applications a jumper must be placed between 11 and 12 of the field wiring terminal block In this mode no further communications will take place during travel If the master detects the presence of a second unit the master will continue to query t...

Страница 27: ...he high voltage power is good and the low voltage power is bad check transformer wiring and replace transformer No LEDs illuminated on the control board If both primary and secondary power is good check to make sure that the J2 connector is making good contact with the pins on the board If all is good replace the control board The relays chatter when the operator begins to move Low secondary low v...

Страница 28: ...lley as possible without coming into contact with them or the pulley Replace the sensor if it is adjusted correctly but continues to fail The operator opens immediately upon power up and does not close Check the red input status LEDs D11 D31 for indication of an active or malfunctioning accessory If any red LEDs are on check the corresponding input An installed accessory may be wired incorrectly o...

Страница 29: ...perator as needed 6 It is suggested that while at the site voltage readings be taken at the operator Using a Digital Voltmeter verify that the incoming voltage to the operator it is within ten percent of the operators rating IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of SEVERE INJURY or DEATH 1 READ AND FOLLOW ALL INSTRUCTIONS 2 NEVER let children operate or play with gate controls Keep the ...

Страница 30: ...5 OR OR FIELD WIRING FIELD WIRING GL CONTROL BOARD GL CONTROL BOARD 24VAC IN 24VAC IN 24VAC COMMON 24VAC COMMON SOFT OPEN SOFT OPEN B LIMIT B LIMIT CONTACTOR B CONTACTOR B RADIO COMMAND RADIO COMMAND SHADOW SHADOW 24 VDC 24 VDC CLOSE CLOSE STOP STOP SOFT OPEN SOFT OPEN HARD OPEN HARD OPEN INT LOOP INT LOOP OBS OPEN OBS OPEN OBS CLOSE OBS CLOSE 24 VAC COMMON 24 VAC COMMON DC GND DC GND LOCK 1 LOCK ...

Страница 31: ...t 2 E9 Control Box 1 E10 Tie Wrap 14 2 E11 Aluminum Standoff 1 E12 Nylon Standoff 2 E13 Terminal Strip Insulator 2 E14 Tinnerman Nut 5 E15 Plastic Card Guide 6 1 INDIVIDUAL PARTS ITEM PART DESCRIPTION QTY 1 74 18465 Housing Assembly 1 2 10 18462 Front Cover 1 3 10 G0326 Switch Box Cover 1 4 23 3001 DPST On Off Switch 1 5 Conduit Box 1 6 65RSWD Pad Mount Kit 1 7 65RSWP Pedestal Mount Kit 1 8 76 G05...

Страница 32: ... S D10 A4 A6 A5 1 8 A7 A7 A3 A7 A2 D9 D12 A1 E5 D8 E2 E11 E7 D15 D13 E15 E12 D5 D1 D23 D18 D6 A9 A12 D21 D22 9 D3 D16 4 5 2 7 6 Optional Optional E8 E8 D14 D17 D19 D20 D2 D7 E3 E4 E13 E6 3 D11 A8 A11 A10 A11 E1 E10 E14 E14 E9 D4 A E D ...

Страница 33: ...EDGES MODEL DESCRIPTION G65MG0204 Miller MG020 2 wire electric edge for gates Sensitized on three sides Requires mounting channel 4 1 2 m long G65MG0205 Miller MG020 2 wire electric edge for gates Sensitized on three sides Requires mounting channel 5 1 5 m long G65ME12C5 Mounting Channel 5 1 5 m long G65MGR205 Miller MGR20 2 wire electric edge in 5 1 5 m lengths for 2 5 cm round post G65MGS205 Mil...

Страница 34: ...operation All inputs are normally open and momentary except the stop N C The following instructions are based upon UL325 and include recommendations for significant increase in safety We strongly recommend that you follow the UL guidelines presented throughout the manual Installation device instructions always follow the instructions provided by the manufacturer when installing and adjusting any c...

Страница 35: ...35 O P E R A T O R N O T E S ...

Страница 36: ...le option ALL IMPLIED WARRANTIES FOR THE PRODUCT INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE TWO YEAR LIMITED WARRANTY PERIOD SET FORTH ABOVE AND NO IMPLIED WARRANTIES WILL EXIST OR APPLY AFTER SUCH PERIOD Some States do not allow limitations on how long an implied warranty lasts so the above limitation ...

Отзывы: