I N S TA L L AT I O N

CONCRETE PAD

The concrete pad for operator mounting should be approximately
24" x 24" x 24" in order to provide adequate weight and structure
to insure proper and stable operation. Pad should be 6" above
finished grade (street level) or 6" above top of curb if one is
present. Be sure to position pad so that it is not so close that it
will interfere with the wheel mounting/axle bolts on the gate or
that it is so far away that the rear mounting holes in the base will
be too close to the edge of the concrete form.

NOTE:

Pad must always extend below the frost line in areas

where the ground freezes.

ANCHORS

Proper anchors for fastening operator to pad will be a 1/2" x 6"
wedge anchor patterned to match the mounting base of the unit.
They should be installed with approximately 1" showing above
concrete surface in order to allow for the 1/4" thick base plate as
well as washers for leveling. Mounting hole pattern is 8 1/4" wide
by 9 1/8" deep. The rear mounting hole centers (nearest to gate)
will need to be between 5 1/4" and 7" from gate if the chain
brackets that are provided are to be used (based on a gate with a 
2" x 2" box tubing frame).

CONDUITS

The area available in base of unit to position conduits is 10 3/4"
wide by 7 1/4" deep. All conduits must be cut down to 1 1/2" in
height to allow for the insertion of the equipment accessory shelf.
The equipment accessory shelf maybe installed after all conduits
are cut to proper height and all wiring has been properly routed.

NOTE:

Do not attempt to hook up the 120VAC mains if wires are

LIVE or HOT. Be sure power is off.

CHAIN INSTALLATION

Before beginning to install the chain, be sure that the centerline of
the mounting holes in the chain brackets are 8 1/2" above the
mounting pad. Once the brackets have been installed and that the
mounting holes in the brackets line up with the bottom of idler
pulleys, connect one end of the chain to one end of the gate. Next
thread the chain through the idlers and drive sprocket, then
attach it to the other end of the gate. Cut chain so that the chain
tensioners will not be adjusted out, allowing for as much future
tightening as possible.

SAFETY EDGE INSTALLATION

See safety page in front of manual

It is highly recommended that a pressure sensing edge (safety
edge) be installed at the leading edge and at all hazard and pinch
points of the gate. Choose an edge that will cover the full height
of the gate. It should be installed securely and any coil cord used
to send the signal back to the operator should be cut so that
excess cord be eliminated to prevent it from getting tangled in the
gate or mechanism. Edges that are to REVERSE and re-open a
closing gate connect to J5 #9 - #12. Edges that are to STOP the
gate that is opening or closing will connect to the 2 pins on the
JP2 block near the center of the board.

Gate

Operator
Frame

Chain

8 1/4"

9 1/8"

5 1/4" Min.

7"  Max.

Concrete
Pad

Conduit Area

10 3/4"

7 1/4"

Allow enough space
between pad and
wheel bolts on gate.

Содержание LIFTMASTER PROFESSIONAL MSLDCBB

Страница 1: ...unit must only be installed by an experienced technician Disconnect AC power and batteries before servicing IMPORTANT Read and understand Warranty Page first Batteries not included MUST be connected f...

Страница 2: ...t Locations 16 MEGA SLIDE UL PARTS LIST Part Numbers and Descriptions 17 Parts Shipped 17 OPERATOR NOTES 18 WARRANTY 19 REPAIR PARTS AND SERVICE 20 TA B L E O F C O N T E N T S IMPORTANT SAFETY INSTRU...

Страница 3: ...is class operator is approved for the application of the operator 1 2 3 or 4 required ______ A sphere with a 2 1 4 diameter cannot be pushed through the gate or fixed panel ______ A safety screen mesh...

Страница 4: ...erator must be in the line of sight and must be an intended reset Access control devices of any kind that required intended on purpose activation may be used for this reset Devices that will cause an...

Страница 5: ...e secondary stop photo beam should be installed along the gate s path that is covered when open Photo beams are to be installed according to their manufacturer s instructions and are to be placed in a...

Страница 6: ...ds installed covering all cantilever wheels required All controls located far out of reach of gate fixed panel and operator required This class operator is approved for the application of the operator...

Страница 7: ...y to persons use photo electric eyes on both sides of gate and pressure sensing edges at all pinch points and at the front leading edge of the gate Safety loops vehicle detectors should be installed i...

Страница 8: ...helf maybe installed after all conduits are cut to proper height and all wiring has been properly routed NOTE Do not attempt to hook up the 120VAC mains if wires are LIVE or HOT Be sure power is off C...

Страница 9: ...is input to reset the unit after a 2nd sequential obstruction is sensed and gate is locked with siren running This input normally functions as listed below Acts same as 1 2 3 above with S2 6 off With...

Страница 10: ...R any input at J5 with control detectors receivers keypads timers etc wires to it must also be run to the same terminals of the second Along with these control wires both operators MUST share a common...

Страница 11: ...delay if activated MODE SELECTIONS SWITCH PACK S2 6 8 SWITCH 6 Sets auxiliary open input terminal 4 at J5 to be pulse open pulse close example residential applications SWITCH 7 AUTO CLOSE TIMER Defaul...

Страница 12: ...vel as possible but still ensuring that it will slow down just before reaching the closed position INSTANT REVERSE DEVICE IRD The instant reverse device is an internal circuit that continuously monito...

Страница 13: ...can be used with up to 15 rolling code remotes or passwords in HIGH security mode Alternately it can be used with up to 31 of any type remote in NORMAL security mode including any combination of roll...

Страница 14: ...the right side of the gate operator frame Once turned off motor will not run and gate can be pushed by hand T R O U B L E S H O O T I N G Flip switch up for normal operation Flip switch down to diseng...

Страница 15: ...DEVICE Gate will open when activated by an access control device When timer expires if used gate will close Figure 2 Terminal 5 is safety input Terminals 1 2 and 3 are open inputs DUAL DIRECTION AS E...

Страница 16: ...AC XFMR MOTOR RED YEL YEL BLU ORG 24VDC REQULATED F4 F3 1 AMP DC F1 H BEAT BATTERY LOW AC POWER C O N T R O L B O A R D L AY O U T COMPONENT LOCATIONS Accessory power is 24VDC regulated rated at 500...

Страница 17: ...BER DESCRIPTION 12 MS014 Siren 100 db 13 MS015 Transformer 110 220 VAC 24VAC 14 MS016 Duplex Outlet MS017 Bolt and Nut 4 Reducer 15 MS018 Idler Pulley Bolt Washer and Nut 16 MS019 120 VAC On Off Switc...

Страница 18: ...18 OPERATOR NOTES...

Страница 19: ...erating freely or not on level ground The warranty set forth above is entirely exclusive and no other warranty whether written or oral is expressed or implied LiftMaster inc specifically disclaims any...

Страница 20: ...andard Time 6 00 A M TO 7 00 P M Monday through Friday 8 00 A M TO 4 30 P M Saturday www liftmaster com WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART NAME MODEL NUM...

Отзывы: