background image

7

Installation

IMPORTANT INSTALLATION INSTRUCTIONS

To reduce the risk of SEVERE INJURY or DEATH:

WARNING 

WARNING 

WARNING 

WARNING 

  1.   READ AND FOLLOW ALL INSTALLATION WARNINGS AND 

INSTRUCTIONS.

  2.   Install door operator ONLY on properly balanced and 

lubricated door. An improperly balanced door may NOT 
reverse when required and could result in SEVERE INJURY 
or DEATH. 

  3.   ALL repairs to cables, spring assemblies and other 

hardware MUST be made by a trained door systems 
technician BEFORE installing garage door opener.

  4.   Disable ALL locks and remove ALL ropes connected to 

door BEFORE installing garage door opener to avoid 
entanglement.

  5   Mount the emergency release within reach, but at least 6 

feet (1.83 m) above the fl oor and avoiding contact with 
vehicles to avoid accidental release.

  6.   NEVER connect door operator to power source until 

instructed to do so. 

  7.   NEVER wear watches, rings or loose clothing while 

installing or servicing the garage door opener. They could 
be caught in door or operator mechanisms.

  8.   Install wall-mounted door control:  
  •  within sight of the door. 
  •   out of reach of children at minimum height of 5 feet 

(1.5 m).

  •  away from ALL moving parts of the door.
  9.   Install the Entrapment Warning Placard next to the door 

control in a prominent location.

10.   Place manual release/safety reverse test label in plain view 

on inside of door.

11.   Upon completion of installation, test safety reversal 

system.

1

1

Attach Mounting Bracket to Garage Door Opener

2

Loosely attach slotted side of mounting bracket to the same side of the garage door 
opener as the collar, using self-threading screws provided.

NOTE:

 Do not tighten screws until instructed.

Socket Wrench

Assembly

HARDWARE

Screw
#10-32

Содержание LiftMaster Elite Security+ 3800PLD

Страница 1: ...afe operation The model number label is located behind the hinged door of your opener DO NOT exceed 10 complete cycles of door operation per hour This product is intended for installation only by trai...

Страница 2: ...r Opener 26 Troubleshooting 26 27 Smart Control Panel Messages 28 Diagnostic Chart 29 PROGRAMMING 30 32 To Add or Reprogram a Hand Held Remote Control Model 895MAX 30 To Erase All Codes From Garage Do...

Страница 3: ...ust extend at least 1 5 inches 2 5 12 cm past the bearing plate An electric outlet is required within 6 feet 1 8 m of the installation area If outlet does not exist contact a quali ed electrician Depe...

Страница 4: ...s of door operation per hour To prevent possible SERIOUS INJURY or DEATH ALWAYS call a trained door systems technician if garage door binds sticks or is out of balance An unbalanced garage door may NO...

Страница 5: ...ing Sensor Bracket 2 The Protector System 2 Safety Reversing Sensors 1 Sending Eye and 1 Receiving Eye with 2 Conductor White White Black Bell Wire attached Safety Labels and Literature Hardware Acces...

Страница 6: ...the collar is seated all the way on motor shaft until stop is reached Position the collar so the screws are facing out and are accessible when attached to the torsion bar Tighten the screws on both si...

Страница 7: ...vehicles to avoid accidental release 6 NEVER connect door operator to power source until instructed to do so 7 NEVER wear watches rings or loose clothing while installing or servicing the garage door...

Страница 8: ...e garage door opener back onto the torsion bar until pilot holes align with bracket Securely tighten collar screws to the torsion bar to 12 14 ft lbs of torque Securely tighten both set screws NOTE Yo...

Страница 9: ...nsure rail surface is clean and attach lock template to track Drill holes as marked on the template Fasten power door lock to the outside of the garage door track with hardware provided Run bell wire...

Страница 10: ...he wall anchors 2 and the 8 hex screws 2 provided in the hardware bag Attach the cable tension monitor to the wall using the hardware provided Make sure that the roller is on top of the cable Run bell...

Страница 11: ...in place For standard installations ONLY Run bell wire up wall and across ceiling to the garage door opener Use insulated staples to secure wire in several places DO NOT pierce wire with a staple crea...

Страница 12: ...the hinge and pressing up on the other end to latch into place Plug in the light to outlet NOTE Light will not operate until the garage door opener is activated Install Remote Light 1 1 1 2 2 3 3 4 4...

Страница 13: ...parts 9 Reinstall the cover To avoid installation difficulties do not run the garage door opener at this time To avoid installation difficulties do not run the garage door opener at this time To redu...

Страница 14: ...iling joist or wall stud 2 Attach the SPS to the support with the 1 1 2 inch lag screws 2 provided There are mounting holes on either side of the SPS 3 Connect the SPS cord into the connector on the b...

Страница 15: ...gned to clip onto the track of sectional garage doors without additional hardware If it is necessary to mount the units on the wall the brackets must be securely fastened to a solid surface such as th...

Страница 16: ...ed arms facing the door Be sure there is enough clearance for the sensor beam to be unobstructed 2 If additional depth is needed an extension bracket see Accessories or wood blocks can be used 3 Use b...

Страница 17: ...hite to white and white black to grey 3 4 5 7 16 11 mm HARDWARE WHT BLK Bell wire WHT Staple 1 Slide a 1 4 20x1 2 carriage bolt head into the slot on each sensor Use wing nuts to fasten safety reversi...

Страница 18: ...he door is closing the door will reverse If the door is already open it will not close The remote lights will blink 10 times If bulbs are not installed 10 clicks can be heard See page 15 ALIGNING THE...

Страница 19: ...he door you may toggle the door back and forth using the black and purple buttons to reach the desired closed position Push the door control or programmed remote control This sets the DOWN close limit...

Страница 20: ...n and close the door fully inspect the door to ensure that it is balanced properly and is not sticking or binding If the door is not stopping exactly where you would like it repeat Program the Travel...

Страница 21: ...rotector System Press the remote control push button to open the door Place the opener carton in the path of the door Press the remote control push button to close the door The door will not move more...

Страница 22: ...door to the garage door opener pull the emergency release handle straight down a second time until a click noise is heard from the garage door opener The door will reconnect on the next UP or DOWN ope...

Страница 23: ...and one Security Keyless Entry System If you purchase a new remote or if you wish to deactivate any remote follow the instructions in the Programming section Activate your garage door opener with any...

Страница 24: ...c Light Feature The garage door opener light will turn on automatically when a person enters the garage When a person walks in front of the door control the light will come on for ve minutes then shut...

Страница 25: ...ontrols gate operators or access control systems Press and hold the button down until the door or gate starts to move The remote control will operate from up to 3 car lengths away on typical installat...

Страница 26: ...connection at the door control a short under the staples or a broken wire Are the wiring connections correct Review Installation Step 5 page 11 The door operates from the Door Control but not from th...

Страница 27: ...Open and close the door manually A properly balanced door will stay in any point of travel while being supported entirely by its springs If it does not disconnect the garage door opener and call a tr...

Страница 28: ...message will appear when the learn button has been pressed a second time on the door control or anytime on the garage door opener The garage door opener is ready to program another remote control by s...

Страница 29: ...nd secure brackets Verify door track is rmly secured to wall and does not move SYMPTOM Door travels 2 3 inches and stops Reprogram limits and forces See Adjustment section If the motor unit continues...

Страница 30: ...e remote control turn on Press and release the Learn button on the garage door opener The Learn LED will light Within 30 seconds Press and release the Prog Learn button on the Smart Control Panel twic...

Страница 31: ...en press ENTER The door should move To set a temporary PIN You may authorize access by visitors or service people with a temporary 4 digit PIN After a programmed number of hours or number of accesses...

Страница 32: ...the garage door opener using the hand held remote door control or keyless entry The code has been learned when the remote light comes on Your garage door opener remote light has already been programme...

Страница 33: ...41A6104 Cable tension monitor 8 41C0902 Mounting bracket 9 41A5034 Safety sensor kit receiving and sending eyes with 3 feet 9 m 2 conductor bell wire attached KEY PART NO NO DESCRIPTION 10 41A6388 Col...

Страница 34: ...pener Assembly Parts 3 2 6 5 4 1 KEY PART NO NO DESCRIPTION 1 41DJ001 Logic board complete with plate 2 41A6408 Travel Module 3 41C168 Transformer KEY PART NO NO DESCRIPTION 4 41A6095 Motor with brack...

Страница 35: ...closed Monitors up to 4 garage doors by adding additional sensor modules 915LM Garage Door Monitor Sensor Additional accessory sensor for homes with multiple garage doors 916LM EverCharge Standby Pow...

Страница 36: ...confirmed to be defective and covered by this limited warranty will be repaired or replaced at Seller s sole option at no cost to you and returned pre paid Defective parts will be repaired or replace...

Отзывы: