background image

INSTALLATION OF THE CONTROL BOX

The CB11 control board was designed for installation in a special,
waterproof box (203391). Before fitting, measure the required
distances and determine the correct holes. Use a screwdriver to force
the plastic out of the holes. Insert threaded cable connections with
strain relief, hold the box against the surface on which it is to be
mounted. Insert screws through the mounting holes in the rear panel
and tighten. The motor control unit is a highly modern electronic unit
controlled by a microprocessor. It has all wiring facilities and functions
required for safe operation. Moisture and water will destroy the control
board. Make sure under all circumstances that water, moisture or storage
moisture cannot penetrate the control board. Make sure that all openings
and cable entries are sealed watertight. The control box with the motor
control unit is mounted with the cable entries facing down. It must not be
permanently exposed to direct sunlight. The electronics can be used for
the precise adjustment of the push-pull torque. The gate can be held by
hand if the fitting/setting is correct. During operation, the gate can be
stopped at all times via remote control, push-button or key-operated
switch. The gate wing requires a firm stop for the “OPEN” and
“CLOSED” positions, because the  gate drives have no limit switch.

CURRENT DISTRIBUTION

The cable coming from the drive arm must be inserted into a
commercial, waterproof distribution box. A firm cable connection can
then be established from the distribution box to the control board. It is
frequently possible to lead the drive, that is fixed directly next to the
control board, directly into the box. Never lay distribution boxes under
the ground.

The following minimum cable cross-sections should be used: 

• 100-230 volts 1.5 mm² or more more
• 0-24 volts 0.5 mm² or more more
Tips: Bell wires often cause problems when used, because they lose
too much voltage if lines are long. Disconnect the cables in the cable
trunkings i.e. the motor cable and the cable for the photocell, in
particular for key-operated switches and start buttons (coming from the
house), otherwise malfunctions are possible if lines are long.

TECHNCAL DATA

Voltage: 

230 V~ ±10 % 50 Hz 

Max. consumption: 

22 mA

Drive max.: 

230 V~ 50 Hz 1000 W max 

Power supply for accessories: 24 Vdc / 0.5 A max 
Operating temperature: 

-25 ºC ÷ 55 ºC 

Operating modes: 
Standard/ standard & no self-hold (hold to run) in closing/
Automatic with stop/ residential/ channel separation/ car park/
no self-hold (hold to run) 
Max. running time: 

80 sec 

Rest time: 

0 ÷ 150 sec 

Dimensions: 

124x152 mm (without box) 

GB-1

PLEASE START BY READING THESE IMPORTANT SAFETY RULES • SAVE THESE INSTRUCTIONS

This safety alert symbol means "Caution" - failure to comply with such an instruction involves risk of personal injury or damage
to property. Please read these warnings carefully.

This gate drive mechanism is designed and tested to offer appropriately safe service provided it is installed and operated in
strict accordance with the following safety rules.

Incorrect installation and/or failure to comply with the following instructions may result in serious personal injury or property
damage.

Installation and wiring must be in compliance with
your local building and electrical installation codes.
Power cables must only be connected to a properly
earthed supply.

Any entrapment possibility by the moving wing between
wing & walls must be secured with safety edges or IR-
sensors.

.

Disconnect electric power to the system before making
repairs or removing covers.

A disconnecting device must be provided in the
permanently-wired installation to guarantee  all-pole
disconnection by means of a switch (at least 3mm
contact gap) or by a separate fuse.

When using tools and small parts to install or carry
out repair work on a gate exercise caution and do not
wear rings, watches or loose clothing.

Make sure that people who install, maintain or
operate the gate drive follow these instructions. 

Keep

these instructions in a safe place so that you can refer to
them quickly when you need to.

Please remove any locks fitted to the gate in order to
prevent damage to the gate.

It is important to make sure that the gate always runs
smoothly. Gates which stick or jam must be repaired
immediately. 

Employ a qualified technician to repair the

gate, never attempt to repair it yourself.

Keep additional accessories away from children. Do not
allow children to play with pushbuttons or remote controls.
A gate can cause serious injuries as it closes. 

After the installation a final test of the full function of
the system and the full function of the safety devices
must be done.

The full protection against potential squeeze or
entrappment must work direct when the drive arms
are installed.

This drive cannot be used with a gate incorporating a
wicket door unless the drive cannot be operated with
the wicket door open.

IMPORTANT FITTING AND OPERATING INSTRUCTIONS

ATTENTION

709438

Содержание CB10

Страница 1: ...električne instalacije CB10 Istruzioni e installazione elettrica CB10 Instruktie en electrische installatie CB10 Manuais e instalação eléctrica CB10 Instrukcja i instalacja elektryczna CB10 Инструкции и электромонтаж CB10 GB F D E HR GR CZ H I NL P PL www liftmaster com Email info chamberlain com 0678 AT BA BE BG CH CY CZ DE DK ES FR GB GR HR HU IE IS IT LU MT NL NO PL PT RO RU SE SI SK TR YU RUS ...

Страница 2: ...709438 Chamberlain GmbH 2010 all rights reserved ...

Страница 3: ... modes Standard standard no self hold hold to run in closing Automatic with stop residential channel separation car park no self hold hold to run Max running time 80 sec Rest time 0 150 sec Dimensions 124x152 mm without box GB 1 PLEASE START BY READING THESE IMPORTANT SAFETY RULES SAVE THESE INSTRUCTIONS This safety alert symbol means Caution failure to comply with such an instruction involves ris...

Страница 4: ...ypical configuration of a unit 1 Motor 2 Control board 3 photocell active for closing max height 200 mm First photocell 4 photocell active for opening max height 200 mm Second photocell 5 Flashing light optional Important visual information on the movement of the gate 6 Key operated switch Is mounted on the outside The gate is opened by key or by entering a number 7 Contact strip optional Safeguar...

Страница 5: ...ton Learn Delete radio channel 1 8 CH2 pushbutton Learn Delete radio channel 2 9 L1 pushbutton Learning the distance covered 10 JMP1 jumper Programming the photocell 11 DIP1 Dip switch block 12 PT4 potentiometer Force setting drive 2 13 PT3 potentiometer Force setting drive 1 14 PT2 potentiometer Automatic closing 15 PT1 potentiometer Bipart delay GB 3 DESCRIPTION OF THE LEDs RED LEDs should be sw...

Страница 6: ...or 1 master is opened first and closed last It is necessary that the bipart delay is always set so that nobody is caught between the wings when they close Left stop Bipart delay OFF PT2 TRIMMING POTENTIOMETER 2 AUTOMATIC CLOSING TIMER TO CLOSE The waiting time for the gate for GATE OPEN can be defined The gate is closed 0 150 sec after the set time expires Only working with failsafe photocell s 77...

Страница 7: ...ile pedestrian stops the next one closes Residential Gate closed 1 impulse opens the next one closes the next one opens the next one closes etc Gate closed 1 impulse opens pedestrian door the next one closes immediately Impulse while pedestrian closes the gate immediately Impulse during the rest closes the gate immediately Impulse during automatic closing opens the gate immediately Impulse during ...

Страница 8: ...rd LED off OK LED on constantly control board disables LED flashes OK no photocell connected Cable cross section 0 5 mm2 or more Voltage 12 24 volts AC DC Do not use any fixed copper lines Do not lay any 230 volt cables in parallel and do not lay any 2 cables in the same cable trunking open öffnen ouvrir open close schliessen fermer sluiten close schliessen fermer sluiten open öffnen ouvrir open J...

Страница 9: ...g range of the gate Connection to terminals 19 20 stop Relay output of the evaluation unit when using failsafe photocells NO closer If relay photocells are used as NC opener Automatic closing function not recommended Attention The only safeguard that is not permitted according to EU standard 24 VDC OUTPUT For relay infrared senors or other devices e g receivers max 500 mA Do not use any fixed copp...

Страница 10: ...E transmitterS Press button CH1 The LED Learn1 lights up red Now press one of the transmitter s button for approx 5 seconds The LED Learn 1 flashes now Finished Proceed in exactly the same way for CH2 However now press one of the transmitter s buttons that has not yet been assigned Up to 128 transmitters can be programmed in this way To delete the programmed transmitter setting simply press button...

Страница 11: ...gins at this position 4 Press L1 again limit stop reached 2 seconds Wing 2 now starts automatically 5 Press L1 again soft stop OPEN for wing 2 begins at this position 6 Press L1 again limit stop reached 2 seconds Wing 2 now restarts automatically and closes 7 Press L1 again soft stop CLOSED for wing 2 begins at this position 8 Press L1 again limit stop CLOSED reached 2 seconds Wing 1 now starts au...

Страница 12: ...bserve LEDs find and rectify fault The gate opener doesn t respond at all although the controller has been connected LEDs are on 1 Remote control has not been programmed 2 LEDs indicate a fault 3 Photocell connected incorrectly 4 Jumper between STOP and COM missing 5 Motor terminal possibly not connected properly 1 Programming remote control 2 Find and rectify fault s see description of LEDs 3 Che...

Страница 13: ...ends the gate and or post 1 A B dimensions correct 2 Force set too high 3 Reinforce gate 1 Check A B dimensions 2 Turn force potentiometer in an anticlockwise direction 3 Possibly screw gate opener to a reinforcement plate post Possibly fit reinforcement plate at point of pull push pressure gate wing Use suitable screws and plugs Can different A B dimensions be used on the two sides Generally spea...

Отзывы: