Gate opener does not function / does not respond
when button is pressed. 

1. Connection to button is loose. 
2. STOP switch connection is loose; STOP
LED is off. 
3. Obstacle is blocking photocell in direction
of movement. 
4. Safety edge is damaged or has
encountered an obstacle. 
5. Gate opener is still released. 

1. Check button and COM connections. 
2. Check STOP switch connections
(STOP and COM). 
3. Remove obstacle. 
4. Remove obstacle and check
connections and wiring. 
5. Lock gate opener. 

The gate opener does not open the gate fully.

1. Are the post dimensions A+B correct? 
2. Has the running time of the controller been
set correctly? 
3. Has the force been set correctly? 

1. Check A+B dimensions. 
2. Reprogram as required – plus
approx. 3 seconds. 
3. Correct force setting (gate opener
runs somewhat slower in windy
conditions). 

The controller doesn’t respond when I alter the
Dip-switches. 

Disconnect controller from power
supply, then alter Dip-switches. 

“Timer to close” doesn’t work.

1. Only works if the 2-cable photocell
770E(ML) or 771E(ML) has been
installed. 
2. Then turn “timer to close”
potentiometer in a clockwise direction. 

The gate opener doesn’t respond at all; no LED is
on. 

Possibly power failure. 

1. Check conductor and zero conductor. 
2. Check house fusing. 

Immediately after the gate has started moving, it
stops and reverses. 

Obstacle in area of gate. 

Check area of gate for objects 

The gate opener hums slightly but has no force

1. Capacitor is not correctly connected to the
brown and black cable. 
2. Force has not been set. 
3. The gate opener has been released. 

1. Check wiring of capacitor. 
2. Turn force potentiometer in a clockwise
direction. 
3. Lock gate opener. 

The gate opener only works when I press and
hold the button on the remote control.

1. Controller in ‘hold to run’ operating mode. 
2. A safety facility is not working correctly
(photocell, safety edge). 

1. Disconnect controller from power supply,
then alter Dip-switches. 
2. Observe LEDs; find and rectify fault. 

The gate opener doesn’t respond at all, although
the controller has been connected (LEDs are on). 

1. Remote control has not been programmed. 
2. LEDs indicate a fault. 
3. Photocell connected incorrectly. 
4. Jumper between STOP and COM missing. 
5. Motor terminal possibly not connected
properly. 

1. Programming remote control. 
2. Find and rectify fault(s) (see description
of LEDs). 
3. Check photocell connection /
programming. 
4. Connect simple jumper. 
5. Check terminals and connections. 

The gate opener stops suddenly and then restarts
only after a lengthy pause. 

If the gate is operated constantly, the motor
will reach its cut-off temperature - protective
facility - as the gate opener is not designed
for permanent operation. 

Allow motor sufficient time to cool (min. 15
minutes). 

How long is the probable service life of a gate opener? 

When used for private purposes, a correctly installed gate opener can
operate perfectly for in excess of 10 years. Both the gate and the gate
opener must be checked regularly and serviced in accordance with
their respective instructions. 

What happens in case of power failure? 

All Chamberlain gate openers are equipped with a release system by
means of which the gate can be operated manually in case of power
failure. 

How long does it take to install a gate opener? 

Depending on your specific technical skills, the installation of the
mechanical components can take approx. 3 to 8 hours. Firstly, the gate
needs to be properly prepared such that installation work can

commence. The electrical connection work takes approx. 1 to 2 hours.

Each user should be instructed for at least 30 minutes with regard to
the operation of the gate opener, whereby its functionality should be
demonstrated and safety aspects, protective facilities and procedure in
case of power failure should all be explained. 

Is it possible to open just one wing of the gate (pedestrian mode)? 

Yes, it is possible. This process can be operated via remote control (a
2-channel remote control is the minimum requirement here) or via
switch operation (see “Standard” operation mode setting).

Frequently asked questions

Содержание CB10

Страница 1: ...električne instalacije CB10 Istruzioni e installazione elettrica CB10 Instruktie en electrische installatie CB10 Manuais e instalação eléctrica CB10 Instrukcja i instalacja elektryczna CB10 Инструкции и электромонтаж CB10 GB F D E HR GR CZ H I NL P PL www liftmaster com Email info chamberlain com 0678 AT BA BE BG CH CY CZ DE DK ES FR GB GR HR HU IE IS IT LU MT NL NO PL PT RO RU SE SI SK TR YU RUS ...

Страница 2: ...709438 Chamberlain GmbH 2010 all rights reserved ...

Страница 3: ... modes Standard standard no self hold hold to run in closing Automatic with stop residential channel separation car park no self hold hold to run Max running time 80 sec Rest time 0 150 sec Dimensions 124x152 mm without box GB 1 PLEASE START BY READING THESE IMPORTANT SAFETY RULES SAVE THESE INSTRUCTIONS This safety alert symbol means Caution failure to comply with such an instruction involves ris...

Страница 4: ...ypical configuration of a unit 1 Motor 2 Control board 3 photocell active for closing max height 200 mm First photocell 4 photocell active for opening max height 200 mm Second photocell 5 Flashing light optional Important visual information on the movement of the gate 6 Key operated switch Is mounted on the outside The gate is opened by key or by entering a number 7 Contact strip optional Safeguar...

Страница 5: ...ton Learn Delete radio channel 1 8 CH2 pushbutton Learn Delete radio channel 2 9 L1 pushbutton Learning the distance covered 10 JMP1 jumper Programming the photocell 11 DIP1 Dip switch block 12 PT4 potentiometer Force setting drive 2 13 PT3 potentiometer Force setting drive 1 14 PT2 potentiometer Automatic closing 15 PT1 potentiometer Bipart delay GB 3 DESCRIPTION OF THE LEDs RED LEDs should be sw...

Страница 6: ...or 1 master is opened first and closed last It is necessary that the bipart delay is always set so that nobody is caught between the wings when they close Left stop Bipart delay OFF PT2 TRIMMING POTENTIOMETER 2 AUTOMATIC CLOSING TIMER TO CLOSE The waiting time for the gate for GATE OPEN can be defined The gate is closed 0 150 sec after the set time expires Only working with failsafe photocell s 77...

Страница 7: ...ile pedestrian stops the next one closes Residential Gate closed 1 impulse opens the next one closes the next one opens the next one closes etc Gate closed 1 impulse opens pedestrian door the next one closes immediately Impulse while pedestrian closes the gate immediately Impulse during the rest closes the gate immediately Impulse during automatic closing opens the gate immediately Impulse during ...

Страница 8: ...rd LED off OK LED on constantly control board disables LED flashes OK no photocell connected Cable cross section 0 5 mm2 or more Voltage 12 24 volts AC DC Do not use any fixed copper lines Do not lay any 230 volt cables in parallel and do not lay any 2 cables in the same cable trunking open öffnen ouvrir open close schliessen fermer sluiten close schliessen fermer sluiten open öffnen ouvrir open J...

Страница 9: ...g range of the gate Connection to terminals 19 20 stop Relay output of the evaluation unit when using failsafe photocells NO closer If relay photocells are used as NC opener Automatic closing function not recommended Attention The only safeguard that is not permitted according to EU standard 24 VDC OUTPUT For relay infrared senors or other devices e g receivers max 500 mA Do not use any fixed copp...

Страница 10: ...E transmitterS Press button CH1 The LED Learn1 lights up red Now press one of the transmitter s button for approx 5 seconds The LED Learn 1 flashes now Finished Proceed in exactly the same way for CH2 However now press one of the transmitter s buttons that has not yet been assigned Up to 128 transmitters can be programmed in this way To delete the programmed transmitter setting simply press button...

Страница 11: ...gins at this position 4 Press L1 again limit stop reached 2 seconds Wing 2 now starts automatically 5 Press L1 again soft stop OPEN for wing 2 begins at this position 6 Press L1 again limit stop reached 2 seconds Wing 2 now restarts automatically and closes 7 Press L1 again soft stop CLOSED for wing 2 begins at this position 8 Press L1 again limit stop CLOSED reached 2 seconds Wing 1 now starts au...

Страница 12: ...bserve LEDs find and rectify fault The gate opener doesn t respond at all although the controller has been connected LEDs are on 1 Remote control has not been programmed 2 LEDs indicate a fault 3 Photocell connected incorrectly 4 Jumper between STOP and COM missing 5 Motor terminal possibly not connected properly 1 Programming remote control 2 Find and rectify fault s see description of LEDs 3 Che...

Страница 13: ...ends the gate and or post 1 A B dimensions correct 2 Force set too high 3 Reinforce gate 1 Check A B dimensions 2 Turn force potentiometer in an anticlockwise direction 3 Possibly screw gate opener to a reinforcement plate post Possibly fit reinforcement plate at point of pull push pressure gate wing Use suitable screws and plugs Can different A B dimensions be used on the two sides Generally spea...

Отзывы: