16
RFID ANTENNA
WIEGAND
REQUEST TO EXIT
READER
PUSH
BUTTON
PROXIMITY
SENSOR
KEYPAD
MAGLOCK
LIGHT
ALARM BYPASS
OR
OR
OR
OR
OR
DOOR STRIKE
RED LED - brown
GREEN LED - orange
DA
TA 1 - white
NEUTRAL
DA
TA 0 - green
GROUND - black
12Vdc - red
PRIMARY RELAY
AUXILIARY RELAY
Model MG1300
Model HES(RS) 1006CLB(R)
NORMALLY CLOSE
Use 18-22 AWG
Use 18-22 AWG
COMMON
NORMALLY OPEN
NORMALLY OPEN
COMMON
COMMON
NC
COM
COM
LOAD
LINE
Isolation
Relay
Low
Voltage
Power
Supply
NO
NO
COM
NO
COM
NO
Power for Maglock
(Not Provided)
DO
NOT
use the power
supply for the controller
Power for Maglock
(Not Provided)
DO
NOT
use the power
supply for the
controller
For AC Power:
Install a Siemens
S10K30MOV
(Metal Oxide Varistor)
or equivalent
For AC Power:
Install a Siemens
S10K30MOV
(Metal Oxide Varistor)
or equivalent
For DC Power:
Install a 1N4005 diode
or equivalent
For DC Power:
Install a 1N4005 diode
or equivalent
COM
REX
NOTES:
• The length of the unshielded
wires should be kept to a minimum
to avoid electrical noise.
• When extending the reader connection,
the shield wire must be connected to an
earth ground bus, but should NEVER be
connected at the reader.
NOTE:
Power supply for
RFID antenna is not provided.
DO NOT use the power supply
for the door controller.
NOTE:
For KPR2000 keypad
wire the pink and black (ground)
wires together.
NOTE:
DO NOT run high voltage power within the CAP2D enclosure. This
configuration has not been evaluated by UL. Use UL Listed Power Limited
Power Supplies and UL Listed Isolation Relays.
Door Access
Disconnect power BEFORE making electrical connections.
Below is an example of a wiring setup for door access. Door access can be
wired to Door 1 or 2.
NOTE:
Power Supplies shall be UL Listed Commercial 294 or 603 power limited
output Power Supplies.
INTRODUCTION
PRE-INSTALL
NETWORK
WIRING
ACCESS CONTROL
INSTALL
Содержание CAP2D
Страница 1: ...LiftMaster CloudTM Connected Access Portal 2 Door Controller INSTALLATION MANUAL Model CAP2D ...
Страница 20: ...Contrôleur de 2 portes à portail d accès connecté LiftMaster CloudTM MANUEL D INSTALLATION Modèle CAP2D ...
Страница 39: ...Controlador de 2 puertas del Portal de acceso conectado LiftMaster Cloud TM MANUAL DE INSTALACIÓN Modelo CAP2D ...