14
LED
Function
tr
Transmitter
r1
IR1 photocell
r2
IR2 photocell
r3
IR3 photocell
i1
Input 1 command
i2
Input 2 command
i3
Input 3 command
Pd
Partial Opening Motor 1 only
d0
Delay Motor 2 in OPEN
dC
Delay Motor 1 in CLOSE
tC
Timer To Close (TTC)
rt
Reversal time after impact
EL
E-lock
rb
Relief Motor 1 for E-lock
LED
Function
FL
Flashing Light
PF
Pre-Flashing
SP
Special contact
St
START Speed in OPEN and CLOSE
Cn
Maintenance counter
PS
Password
F1
Force Motor 1 in Open (protected by PS)
F2
Force Motor 1 in Close (protected by PS)
F3
Force Motor 2 in Open (protected by PS)
F4
Force Motor 2 in Close (protected by PS)
S1
Speed Motors in OPEN (protected by PS)
S2
Speed Motors in CLOSE (protected by PS)
SF
SOFT-STOP Speed in OPEN and CLOSE
(protected by PS)
Fd
Factory default
FE
Finish and Exit
7.7 Advanced Settings
7.7.2 Transmitter Settings
Transmitter function defines how Transmitter commands are working.
Note:
Under settings “01”, “02” and “03”, TTC timer will be overridden
by a transmitter command and will CLOSE the gate.
Under setting “04”, active TTC timer countdown will be re-set to start
again by Transmitter command.
Residential Mode: Open – Close – Open
Standard Mode: Open – Stop – Close – Stop – Open (Default)
Automatic with Stop Mode: Open – Stop – Close – Open
Car Park Mode: Open, to complete Open position. Additional com-
mand during the opening will be ignored
7.7.4 Input Settings
Inputs function defines the way Input commands from external accessories are
executed. Each of the 3 Inputs can be programmed individually.
NOTE:
Under settings “01”, “02” and “03”, TTC timer will be overridden by an Input
command and will CLOSE the gate. Under setting “06”, active TTC timer count-
down will be re-set to start again by an Input command
IR active on CLOSE movement. If IR beam is obstructed, gate re-
verses in complete OPEN position (Default).
IR active on OPEN movement. If IR beam is obstructed gate stops.
When obstruction disappears the gate continues to OPEN.
IR is active on OPEN and CLOSE movement. If IR beam is obst-
ructed on CLOSE movement, gate stops and after the obstruction
disappears gate reverses in complete OPEN position. If IR beam
is obstructed on OPEN movement, gate stops. When obstruction
disappears the gate continues to OPEN.
IR active on CLOSE movement. If IR beam is obstructed, gate re-
verses in complete OPEN position. The activated TTC function will
be overridden 2 seconds after the beam obstruction is eliminated
and will start CLOSE movement not waiting till the end of TTC time
end.
7.7.3 Infrared Photocells Settings
IR functions define functioning mode of Infrared Photocells (IR).
IRs will be auto-learned when installed.
Each of the 3 IR sets can be programmed individually.
NOTE:
Depending on the chosen settings the Partial Opening inputs or Remote
Controls commands will not be executed in both OPEN or CLOSE direction if the
IR beam is obstructed. If IRs are removed, the control board power must be turned
OFF/ON for two times to unlearn.
For check and maintenance of the photocells see the manual of the photocells.
7. PROGRAMMING
Herewith you start with Advanced Settings.