                December 2018  

 

 

 

 

 

EU-Declaration of conformity 
UE-Déclaration de conformité  
EU-Konformitätserklärung 

 

 

Manufacturer 

Chalmit 

Address 

388 Hillington Road, Glasgow. G52 4BL Scotland UK 

Product 

Sterling lIl LED 

Type Examination Certificate 

CML 16ATEX 4101X 

Notified Body 

CML 2503 

ATEX Coding  

II 3 GD 

ATEX Classification 

Group II Category 3 GD 

Equipment Coding 

Ex ec IIC T4 Gc, Ex tc IIIC T76°C Dc IP6X 

Ingress Protection 

IP65 

The technical basis, with respect to equivalence of

 

La base technique, en ce qui concerne l'équivalence de 

Die technische Grundlage hinsichtlich der Normen 

Protection Standards EN 60079-0, EN 60079-7, EN 60079-31

 

Area Classification EN 60079-10-1, EN 60079-10-2.

 

 

of compliance with the EHSRs is valid as there are no changes which materially affect the state of technological progress of the product.

 

en  conformité avec les EESS est valide puisqu'il n'y a aucun changement qui affecte matériellement l'état de l'évolution technologique du 

produit. 

zur Erfüllung der GSGA ist gegeben, da keine Änderungen erfolgt sind, die einen Einfluss auf den technischen Stand des Produkts haben.

 

 

Terms of the directive:

 

Standard & Date Certified to

 

Standards Date Declared to

 

Prescription de la directive:

 

Standard & date certifiée à

 

Normes date Déclaré

 

Bestimmungen der Richtlinie:

 

Standard & Datum 

Zertifiziert nach

 

Standards Datum erklärt

 

2014/34/EU 

Equipment and protective systems intended for use in 

potentially explosive atmospheres.

 

EN 60079-0: 2012 

 

EN 60079-7: 2015 

 

2014/34/UE 

Appareils et les systèmes de protection destinés à être 

utilisés en atmosphères potentiellement explosibles.

 

EN 60079-31: 2014 

 

 

2014/34/EU 

Geräte und Schutzsysteme zur bestimmungs- 

gemäßen Verwendung in explosionsfähigen Bereichen.

 

 

 

 

2014/30/EU 

Electromagnetic compatibility

 

EN 55015 : 2013 

 

2014/30/UE 

Compatibilité électromagnétique

 

EN 61547 : 2009 

 

2014/30/EU 

Elektromagnetische Verträglichkeit

 

EN 61000-3-2 : 2014 

 

 

 

 

 

2014/35/EU 

Low voltage equipment

 

EN 60598-1 : 2015 

 

2014/35/UE

 

Équipements électriques à bas voltage

 

EN 60598-2-5 : 2015 

 

2014/35/EU

 

Niederspannungsgeräte / -systeme

 

EN 60529 : 1992 

 

 

 

 

 

2012/19/EU 

Waste of electrical and electronic equipment

 

 

 

2012/19/UE

 

Déchets d'équipements électriques et électroniques

 

 

 

2012/19/EU

 

Entsorgung der elektrischen und  elektronischen Geräte 

/ Systeme

 

 

 

 

 

 

 

2011/65/EU 

RoHS II Directive

 

 

 

 

 

 

 

 
 
 
 
 

Содержание Sterling III

Страница 1: ...ires Ex ec ATEX IECEx INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS GRP Standard body Important Please read these instructions carefully before installing or maintaining this equipment Good electrical practices should be followed at all times and this data should be used as a guide only Technical Drawing ...

Страница 2: ...neral The type of protection is Ex ec and Ex tc The Zone 2 Zone 22 series LED luminaires are surface mounted or suspended utilising the two holes on the base of the body They are mainly used in harsh environments and are constructed using a corrosion resistant glass reinforced polyester body attached to an injection moulded polycarbonate diffuser by stainless steel toggle clips The control gear an...

Страница 3: ...eam of dry air steam etc which could generate a propagating brush static discharge 3 1 1 Use in Combustible Dust Atmospheres Where the equipment is used in ignitable dust atmospheres reference must be made to the selection and installation standards in order that the equipment is used correctly In particular this applies to the de rating of surface temperature for use where dust clouds may be pres...

Страница 4: ...an adequate seal is made to maintain the IP rating of the enclosure Sealing Washers are provided 3 6 Cabling and Cable Glands 3 6 1 Cables The GRP models have facility for through wiring but do not have a facility for looping The temperature conditions of the supply cable entry point are such that 70ºC ordinary PVC cable can be used 300 500V cable ratings are adequate and no special internal const...

Страница 5: ...thly intervals and more frequently if conditions are severe The time between lamp changes could be very infrequent and this is too long a period without inspection 3 8 1 Routine Examination The equipment must be de energised before opening Individual organisations will have their own procedures What follows are guidelines based on EN IEC 60079 17 and on our experience 1 Ensure LED s are lit when e...

Страница 6: ...on 5 0 Fuse Ratings With the availability of MCB s with a wide range of characteristics the individual engineer can make a better judgement of what is required Use MCB s suitable for inrush currents to reduce ratings Where MCB s are used the type with the higher short time tripping current ratio used for motor starting and lighting should be specified The inrush current can be calculated where cir...

Страница 7: ... Max Surface Temperature Dust 3365 Lumen 2ft Twin 120 277Vac 127 300Vdc 26W 20 C Ta 55 C T4 76 C 6218 Lumen 4Ft Twin 120 277Vac 127 300Vdc 60W 20 C Ta 50 C T4 76 C 8953 Lumen 4Ft Twin 120 277Vac 127 300Vdc 96W 20 C Ta 45 C T4 76 C Typical Standard LED Wiring Diagram Note For other Wiring Diagrams please contact the manufacturer Table B Series Circuit No Off LED Strips Gear Type Lumen Nominal Circu...

Страница 8: ...ine Änderungen erfolgt sind die einen Einfluss auf den technischen Stand des Produkts haben Terms of the directive Standard Date Certified to Standards Date Declared to Prescription de la directive Standard date certifiée à Normes date Déclaré Bestimmungen der Richtlinie Standard Datum Zertifiziert nach Standards Datum erklärt 2014 34 EU Equipment and protective systems intended for use in potenti...

Страница 9: ...ch im Namen von Chalmit dass am Tag der Lieferung des Produkts der Produkte zusammen mit dieser Erklärung das Gerät die Geräte alle technischen und regulativen Anforderungen der oben aufgeführten Direktiven erfüllt Name and Date Mark Poutney 30 08 2018 Technical Manager Nom et Date Directeur technique Name und Datum Technischer Leiter Quality Assurance Notification by Baseefa Ltd Quality Managemen...