I-HDL106-02.doc   

 

Issue 11                      11/05/2020

   

 

 

 

9

 

 
 
 
 

                                             IOM 

– HDL106 Luminaire (ATEX & IECEx)

 

 

2011/65/EU 

RoHS II Directive

 

 

 
 
 

On behalf of the Chalmit, I declare that, on the date the equipment accompanied by this declaration is placed  on the market, the equipment conforms to all 
technical and regulatory requirements of the above listed directives.

 

 

En tant que représentant du fabricant Chalmit, je déclare qu'à la date où les équipements accompagnant cette déclaration sont mis sur le marché, ceux-ci 
sont conformes à toutes les dispositions réglementaires et techniques des directives énumérées ci-dessus.

 
 

 

 

Hiermit bestätige ich, im Namen von Chalmit, dass am Tag der Lieferung des Produkts/der Produkte zusammen mit dieser Erklärung das Gerät/die Geräte 
alle technischen und regulativen Anforderungen der oben aufgeführten Direktiven erfüllt.

   

Name and Date 

Mark Poutney  11/05/2020 

Technical Manager

 

Nom et Date 

Directeur technique

Name und Datum 

Technischer Leiter

 
Quality Assurance Notification by: 

SGS BASEEFA 

Quality Management System Acreditation:

ISO 9001 

Notification d'assurance qualité par: 

1180 

Système de Management Qualité Accréditation:

 

 

Qualitätssicherungsnotifikation durch: 

 

Qualitätsmanagementsystem Akkreditierung: 

 

 

 

Environmental Management System.

ISO 14001 

 

 

Système de gestion de l'environnement.

by/par/durch

 

 

Umwelt kontroll system.

Loyd's Register 

 

 

Certificate No./Certificat N°/Zertifikat Nr.  

LRQ 4005876 

 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 

Содержание HDL106 Series

Страница 1: ...ION AND MAINTENANCE INSTRUCTIONS HDL106 Luminaires ATEX IECEx Important Please read these instructions carefully before installing or maintaining this equipment Good electrical practices should be fol...

Страница 2: ...l unless multiple conductors have been joined in a suitable manner e g two conductors into a single insulated crimped boot lace ferrule 2 Leads connected to the terminals shall be insulated for the ap...

Страница 3: ...umen output photometric data can be requested Power Factor 0 9 minimum Over voltage 375V Looping The looping current rating is 12A 4mm terminals are standard Storage Luminaires are to be stored in coo...

Страница 4: ...the front cover and then remove the LED array assembly Care must be taken when disconnecting and reconnecting wiring If required contact Chalmit Technical 4 0 Mounting Luminaires should be installed...

Страница 5: ...heck condition of enclosure gasket and fastenings Check for any accumulation of moisture Periodic inspection of the enclosure seal should be carried out to ensure that the seal is sound If the luminai...

Страница 6: ...I HDL106 02 doc Issue 11 11 05 2020 6 IOM HDL106 Luminaire ATEX IECEx HIGH VOLTAGE...

Страница 7: ...I HDL106 02 doc Issue 11 11 05 2020 7 IOM HDL106 Luminaire ATEX IECEx LOW VOLTAGE Note For 24 LED luminaires there will only be one LED array connected to the terminal block...

Страница 8: ...l n y a aucun changement qui affecte mat riellement l tat de l volution technologique du produit zur Erf llung der GSGA ist gegeben da keine nderungen erfolgt sind die einen Einfluss auf den technisch...

Страница 9: ...ge ich im Namen von Chalmit dass am Tag der Lieferung des Produkts der Produkte zusammen mit dieser Erkl rung das Ger t die Ger te alle technischen und regulativen Anforderungen der oben aufgef hrten...

Отзывы: