background image

 

 

I-HDL106-02.doc   

 

Issue 11                      11/05/2020

   

 

 

 

8

 

 
 
 
 

                                             IOM 

– HDL106 Luminaire (ATEX & IECEx)

 

 

 

 

EU-Declaration of conformity 
UE-Déclaration de conformité  
EU-Konformitätserklärung 

 

 

Manufacturer 

Chalmit 

Address 

388 Hillington Road, Glasgow. G52 4BL Scotland UK 

Product 

HDL 106 Modular Floodlight/Bulkhead 

EU - Type Examination Certificate 

Sira 09ATEX5159X

Notified Body 

CSA Group Sira    0518    

ATEX Coding  

II 2 GD 

ATEX Classification 

Group II Category 2 GD 

Equipment Coding: 

 

HDL106N  
100V to 254V 50/60Hz 

Ex e mb IIC T4 Gb  ,    Ex tb lllC T103°C Db IP6X     -20

°

C

 

 

Ta

 

 

+50

°

 

 

HDL106N (18V to 54V AC/DC) 

Ex e mb IIC T4 Gb  ,    Ex tb lllC T87°C Db IP6X     -20

°

C

 

 

Ta

 

 

+55

°

 

 

HDL106A 

Ex e mb IIC T6 Gb  ,    Ex tb lllC T70°C Db IP6X     -20

°

C

 

 

Ta

 

 

+50

°

 

Ex e mb IIC T5 Gb  ,    Ex tb lllC T85°C Db IP6X     -20

°

C

 

 

Ta

 

 

+65

°

 

 

Ingress Protection 

IP66/67  

The technical basis, with respect to equivalence of

 

La base technique, en ce qui concerne l'équivalence de
Die technische Grundlage hinsichtlich der Normen 
Protection Standards EN 60079-0, EN 60079-7, EN 60079-18, EN 60079-31.
Area Classification EN 60079-10-1and EN 60079-10-2

 

of compliance with the EHSRs is valid as there are no changes which materially affect the state of technological progress of the product.
en conformité avec les EESS est valide puisqu'il n'y a aucun changement qui affecte matériellement l'état de l'évolution technologique du 
produit. 
zur Erfüllung der GSGA ist gegeben, da keine Änderungen erfolgt sind, die einen Einfluss auf den technischen Stand des Produkts haben.

 

Terms of the directive:

 

Standard & Date Certified to

Standards Date Declared to

Prescription de la directive:

 

Standard & date certifiée à

Normes date Déclaré

Bestimmungen der Richtlinie:

 

Standard & Datum 
Zertifiziert nach

 

Standards Datum erklärt

 

2014/34/EU 

Equipment  and  protective  systems  intended  for  use  in 
potentially explosive atmospheres.

 

EN 60079-0: 2012  

2018 

EN 60079-7: 2007

2015 

2014/34/UE 

Appareils  et  les  systèmes  de  protection  destinés  à  être 
utilisés en atmosphères potentiellement explosibles.

EN 60079-18: 2009 
EN 60079-31: 2009

2015 
EN 60079-31: 2014

2014/34/EU 

Geräte und Schutzsysteme zur bestimmungs-  

gemäßen Verwendung in explosionsfähigen Bereichen.

 

 

 

2014/30/EU 

Electromagnetic compatibility

 

EN 55015 : 2013

 

2014/30/UE 

Compatibilité électromagnétique

 

EN 61547 : 2009

 

2014/30/EU 

Elektromagnetische Verträglichkeit

 

EN 61000-3-2 : 2014

 

 

 

 

2014/35/EU 

Low voltage equipment

 

EN 60598-1 : 2015

 

2014/35/UE

 

Équipements électriques à bas voltage

EN 60598-2-5 : 2015

 

2014/35/EU

 

Niederspannungsgeräte / -systeme

EN 60529 : 1992

 

 

 

 

2012/19/EU 

Waste of electrical and electronic equipment

 

2012/19/UE

 

Déchets d'équipements électriques et électroniques

 

2012/19/EU

 

Entsorgung der elektrischen und  elektronischen Geräte 
/ Systeme

 

 

 

 

 

 

Содержание HDL106 Series

Страница 1: ...ION AND MAINTENANCE INSTRUCTIONS HDL106 Luminaires ATEX IECEx Important Please read these instructions carefully before installing or maintaining this equipment Good electrical practices should be fol...

Страница 2: ...l unless multiple conductors have been joined in a suitable manner e g two conductors into a single insulated crimped boot lace ferrule 2 Leads connected to the terminals shall be insulated for the ap...

Страница 3: ...umen output photometric data can be requested Power Factor 0 9 minimum Over voltage 375V Looping The looping current rating is 12A 4mm terminals are standard Storage Luminaires are to be stored in coo...

Страница 4: ...the front cover and then remove the LED array assembly Care must be taken when disconnecting and reconnecting wiring If required contact Chalmit Technical 4 0 Mounting Luminaires should be installed...

Страница 5: ...heck condition of enclosure gasket and fastenings Check for any accumulation of moisture Periodic inspection of the enclosure seal should be carried out to ensure that the seal is sound If the luminai...

Страница 6: ...I HDL106 02 doc Issue 11 11 05 2020 6 IOM HDL106 Luminaire ATEX IECEx HIGH VOLTAGE...

Страница 7: ...I HDL106 02 doc Issue 11 11 05 2020 7 IOM HDL106 Luminaire ATEX IECEx LOW VOLTAGE Note For 24 LED luminaires there will only be one LED array connected to the terminal block...

Страница 8: ...l n y a aucun changement qui affecte mat riellement l tat de l volution technologique du produit zur Erf llung der GSGA ist gegeben da keine nderungen erfolgt sind die einen Einfluss auf den technisch...

Страница 9: ...ge ich im Namen von Chalmit dass am Tag der Lieferung des Produkts der Produkte zusammen mit dieser Erkl rung das Ger t die Ger te alle technischen und regulativen Anforderungen der oben aufgef hrten...