I-HDL106-02.doc   

 

Issue 11                      11/05/2020

   

 

 

 

2

 

 
 
 
 

                                             IOM 

– HDL106 Luminaire (ATEX & IECEx)

 

 

Type Of Protection   

Ex e mb (Increased safety,encapsulation), Ex tb (dust)

Protection Standards 

(IEC) EN 60079-0, (IEC) EN 60079-7, (IEC) EN 60079-18,  (IEC) EN 60079-31 

Area Classification 

Zone 1 and Zone 2 areas to (IEC) EN 60079-10-1  
Zone 21 and Zone 22 areas to (IEC) EN 60079-10-2

Installation 

  (IEC) EN 60079-14

Certificate 

 

IECEx Certificate of Conformity IECEx SIR 09.0064X 
EU - Type Examination Certificate Sira 09ATEX5159X

Equipment Coding 

 HDL106N  
100V to 254V 50/60Hz

HDL106N  
18V to 54V AC/DC

HDL106A 

 

Ex e mb llC T4 Gb 
Ex tb lllC T103°C Db IP6X 
-20°≤ Ta ≤+50°C 
or 
Ex e mb llC T3 Gb 
Ex tb lllC T103°C Db IP6X 
-20°≤ Ta ≤+59.5°C

Ex e mb llC T4 Gb 
Ex tb lllC T87°C Db IP6X 
-20°≤ Ta ≤+55°C 

Ex e mb llC T6 Gb 
Ex tb lllC T70°C Db IP6X 
-20°≤ Ta ≤+50°C 
or 
Ex e mb llC T5 Gb 
Ex tb lllC T85°C Db IP6X 
-20°≤ Ta ≤+65°C

ATEX Coding 

  II 2GD   

Ingress Protection 

IP66/67  

Laser safety class 

Class 1 LED product

CE Mark 

 

The  CE  marking  of  this  product  applies  to  "The  Electrical  Equipment  (Safety)  Regulations 
2006",  "The  Electromagnetic  Compatibility  Regulations  2004",  the  “Waste  Electrical  and 
Electronic Equipment Regulations 2006” and the "Equipment and Protective Systems intended 
for use in Explosive Atmospheres Regulations 1996". [This legislation is the equivalent in UK 
law of EU directives 2014/35/EU, 2014/30/EU, 2012/19/EU and 2014/34/EU respectively]. 
 

The Equipment is declared to meet the provisions of the ATEX directive (2014/34/EU) 
by reason of the EU Type Examination and compliance with the Essential Health and 
Safety Requirements.  
M Poutney    Technical Manager

 

 

 

SPECIFIC CONDITIONS OF USE

 

(denoted by X after the certificate number). 

1.  Except for internal wiring, not more than one single or multiple strand lead shall be connected into either side 

of any terminal, unless multiple conductors have been joined in a suitable manner, e.g. two conductors into a 
single insulated crimped boot lace ferrule. 

2. Leads connected to the terminals shall be insulated for the appropriate voltage and this insulation shall 
    extend to within 1 mm of the metal of the terminal throat. 
3. When terminals in accordance with certificate Sira 01ATEX3247U are used, all terminal screws, used and 
    unused, shall be tightened down to between 0.5 Nm and 0.7 Nm. 
4. When terminals in accordance with certificate Sira 01ATEX3249U are used, all terminal screws, used and 
    unused, shall be tightened down to between 1.2 Nm and 2 Nm. 
5. When terminals in accordance with certificates Sira 01ATEX3247U and Sira 01ATEX3249U are used, they 
    shall only be installed and wired with cable within a temperature range of -10°C to 80°C. 
6. When cross-connecting combs are used on terminals to certificates Sira 01ATEX3247U and 
    Sira 01ATEX3249U, the relevant conditions associated with those certificates shall be applied. 
7. Cable entry holes shall be fitted with either an appropriately certified cable gland or appropriately certified 
    blanking element. These shall provide and maintain a minimum enclosure ingress protection of IP66 or 
    IP67 as appropriate. 
8. If more than 8 individual LEDs are not illuminated, the LED assembly shall be replaced. 
9. The supply circuit must be protected by a fuse capable of withstanding a prospective short circuit  
     current of 1500 A. 
10. When the Lexan polycarbonate lens is fitted, the equipment shall only be used in areas with a low risk of 

mechanical impact. 

11.Under certain extreme circumstances, the non-metallic parts incorporated in the enclosure of this equipment 

may generate an ignition-capable level of electrostatic charge.  Therefore the equipment shall not be installed 
in a location where the external conditions are conducive to the build-up of electrostatic charge on such 
surfaces.  In addition, the equipment shall only be cleaned with a damp cloth.        

 

Содержание HDL106 Series

Страница 1: ...ION AND MAINTENANCE INSTRUCTIONS HDL106 Luminaires ATEX IECEx Important Please read these instructions carefully before installing or maintaining this equipment Good electrical practices should be fol...

Страница 2: ...l unless multiple conductors have been joined in a suitable manner e g two conductors into a single insulated crimped boot lace ferrule 2 Leads connected to the terminals shall be insulated for the ap...

Страница 3: ...umen output photometric data can be requested Power Factor 0 9 minimum Over voltage 375V Looping The looping current rating is 12A 4mm terminals are standard Storage Luminaires are to be stored in coo...

Страница 4: ...the front cover and then remove the LED array assembly Care must be taken when disconnecting and reconnecting wiring If required contact Chalmit Technical 4 0 Mounting Luminaires should be installed...

Страница 5: ...heck condition of enclosure gasket and fastenings Check for any accumulation of moisture Periodic inspection of the enclosure seal should be carried out to ensure that the seal is sound If the luminai...

Страница 6: ...I HDL106 02 doc Issue 11 11 05 2020 6 IOM HDL106 Luminaire ATEX IECEx HIGH VOLTAGE...

Страница 7: ...I HDL106 02 doc Issue 11 11 05 2020 7 IOM HDL106 Luminaire ATEX IECEx LOW VOLTAGE Note For 24 LED luminaires there will only be one LED array connected to the terminal block...

Страница 8: ...l n y a aucun changement qui affecte mat riellement l tat de l volution technologique du produit zur Erf llung der GSGA ist gegeben da keine nderungen erfolgt sind die einen Einfluss auf den technisch...

Страница 9: ...ge ich im Namen von Chalmit dass am Tag der Lieferung des Produkts der Produkte zusammen mit dieser Erkl rung das Ger t die Ger te alle technischen und regulativen Anforderungen der oben aufgef hrten...

Отзывы: