GB
Settings
53
(*) This menu is activated with only
BUS BridgeNet®
connection
menu
sub
-menu
par
ameter
description
value
default setting
5
PARAMETERS ZONE HEATING2
5
0
Temperature settings
5
0
0
T Day
12°C
5
0
1
T Night
16°C
5
0
2
T set Z2
55°C
5
2
Zone 2 settings
5
2
0
Zone 1 temperature range
0 = Low Temperature
1 = High Temperature
5
2
1
Thermoregulation
0 = Fix fl ow T
1 = Basic Thermoregulation
2 = Room T Only
3 = Outdoor T Only
4 = Room + Outdoor T
5
2
2
Slope (*)
1.5
5
2
3
Off set (*)
0°C
5
2
4
Room Infl uence Proportional (*)
20°C
5
2
5
Max T
82°C
5
2
6
Min T
35°C
5
3
Zone 2 diagnostics
5
3
0
Room T
29°C
5
3
1
Room T setpoint
12°C
5
3
2
Flow temperature
22°C
5
3
3
Return temperature
21°C
5
3
4
Heat Request Z2
OFF
ON
5
3
5
Pump Status
OFF
ON
5
4
Zone 2 pump parameters
5
4
0
Zone pump modulation
0 = Fixed
1 = Modulating on DeltaT
2 = Modulating on Pressure
5
4
1
Target deltaT for pump modulation
20°C
5
4
2
Pump fi xed speed
100%
6
PARAMETERS ZONE HEATING3
6
0
Temperature settings
6
0
0
T Day
19°C
6
0
1
T Night
16°C
6
0
2
T set Z3
55°C
6
2
Zone 3 settings
6
2
0
Zone 3 temperature range
0 = Low Temperature
1 = High Temperature
6
2
1
Thermoregulation
0 = Fix fl ow T
1 = Basic Thermoregulation
2 = Room T Only
3 = Outdoor T Only
4 = Room + Outdoor T
6
2
2
Slope (*)
1.5
6
2
3
Off set (*)
0°C
6
2
4
Room Infl uence Proportional (*)
20°C
6
2
5
Max T
82°C
6
2
6
Min T
35°C