17
GB
installation
Positioning
The device detects the room tempera-
ture, therefore several factors should be
taken into account when choosing an in-
stallation site. Install the device far from
sources of heat (radiators, sunlight, fi re-
places, etc.) and draughts or doorways
and windows, which could affect the
temperature readings. It should be in-
stalled approximately 1.50 metres above
the fl oor level.
Warning
Installation should be performed by a
qualifi ed technician. Prior to wiring the
device, cut off the power supply to the
boiler.
Installation
- Remove the upper part of the Zone
Control (Fig. 1).
- Separate the fi xing base by inserting
a screwdriver into the two slits on the
upper part (Fig. 2).
- Fix the Zone Control base to the wall in
the chosen point, using the wall plugs
and screws provided with the kit (Fig.
3).
- Once the wires have been connected,
replace the upper part by observing
the sequence A-B-C-D (Fig. 4).
4
3
2
1