17
10
In case of problem, or when the boiler has to display a message, the display flashes 2 digits. Please refer to the table bellow
to diagnose the default.
For default 01 and 03, the red indicator 35 is alight (fig.19)
35
Fig. 19
Overheating lock out
FAULT
Code
display
Fault description
Information on functioning
01
Overheating lock out
03
No flame detection
05
Anti freezing system, pump on
06
Anti freezing system, pump and burner on
07
No water circulation in primary circuit
08
No water in the primary circuit
09
Domestic Hot Water thermistor faulty (open circuit)
10
Domestic Hot Water thermistor faulty (short circuit)
11
Central Heating thermistor faulty (open circuit)
12
Central Heating thermistor faulty (open circuit)
18
Attempt to re light
20
Wiring problem
23
Fan speed too low
24
Fan control system defective
29
Three way valve blocked in CH mode
31
Communication problem with the display PCB
32
Communication problem with the main PCB
If the boiler is not set for the gas type, conversion kits are available. To convert the boiler, please use exclusively Chaffoteaux
& Maury parts and proceed as mentioned in the instruction manual provided with the conversion kit, the gas conversion must
be carried out by a CORGI registered engineer.
11
Incorrect Function
Gas Conversion