5
CHECKLIST FOR GAS INSTALLER
CAUTION
Before calling the manufacturer, ensure that all the checkpoints below
conform. Refer to the latest SANS 1539:2017 Annex A ,C & E
Check there is gas in the gas bottle (if bottle is nearing empty change over to
new bottle)
Check that the inlet running pressure is 2.8 kPa (whilst running).
If not correct:
Check that the supply pipe is the correct diameter for the distance
covered.
Check that the regulator is functioning correctly.
The burner must be correctly positioned and sitting flush on the bottom
plate,
Jet is centrally aligned with the burner venturi.
Check for spider webs in the venturi.
The
black
ceramic ash or
Glass
supplied with Chad-O-Chef fireplaces must
be inside the burner & the
white
decorative stone (if applicable) surrounding
the burner.
Ensure that the coals or pebbles supplied by Chad-O-Chef are placed as
recommended with a 10mm gap between them.
DO NOT use more coals or pebbles than recommended and supplied. (See
Page 2)
The room must be bigger than the minimum room size for that fireplace.
(See Page 2)
Ensure that there is adequate ventilation. (See Page 1)
Do not tamper with jets, burners or regulator settings. NEVER MODIFY OR
BEND THE THERMOCOUPLE TO MAKE THE PILOT STAY ALIGHT. CHAD-O-
CHEF products are preset and tested to function efficiently and are approved
by the LPGSA.
Should a burn back occur, i.e. the jet catching alight at the entry to the burner
with a noticeable loud rushing sound: Turn the gas off immediately and
relight after 1 min. If condition persists, contact your gas installer.
Should a leak in the gas be detected, turn off the gas at the gas cylinder, and
contact your installer immediately.
Should there be an unexplained shutdown, which could be the result of
insufficient oxygen in the room, shut off the gas supply, then open windows
and doors in the room, wait 5 min before attempting to restart. If condition
persists, contact your gas installer.