background image

1

GENERAL INSTRUCTIONS AND SAFETY NOTES

Thank you for purchasing your new CHAD-O-CHEF Gas Fireplace  manufactured 
to high standards and tested for compliance with SANS 1539:2017

The manufacturer and /or its agents and distributors will not be held 
responsible for injuries or damages caused by faulty or incorrect installation or 
use of the appliance.

1.  This fireplace provides radiant heat both efficiently and safely, using the latest 

technology, without the need of a flue. 

This appliance consumes oxygen 

when in use and it is important that it is only used in a well ventilated area, 

for the efficient performance of the appliance and for the safety of the 

occupants of the area.

 

2.  No permanent ventilation is required if the room is 92m³ or larger, but an 

opening window is required. Should the room size be smaller than 92m³  
then permanent ventilation will be required. This volume may include up to 
50% of adjacent rooms connected by permanent archways, but not rooms 
separated by a closable door.

3. 

DO NOT

 install in a bathroom.

4. 

DO NOT

 install in a bedroom.

5.  Where applicable, the min. free area of ventilation must be 13 cm² per mJ of 

heat input. The heat input of other gas, wood, coal or paraffin appliances must 
be included in the calculations. It is the installer’s responsibility to do these 
calculations on behalf of the home owner. 

6. This appliance may only be installed by a registered LP Gas installer and 

must comply with the installation requirements of SANS 10087-1.

  Ask to 

be shown the installer’s card with his registration number, before allowing 
the installation work to commence and make a note of his QCC number. 
Upon completion of the installation, the installer is required to explain the 
operational details of the appliance together with the safety instructions. You 
will be asked to sign acceptance of the installation and be provided with a 
completion certificate. You should only sign for acceptance of installation, 
upon commitment from the installer, that it complies with SANS 10087-1 and 
is to your satisfaction.  

Note that if the guarantee card is not signed by yourself and the installer 
and returned to the manufacturer, the product guarantee is invalid.

7.  On initial light-up of your new fireplace, the “newness” will burn off within the 

first few hours of operation. During this period some smoke may be emitted 
from the unit, this should be no cause for concern. Accordingly, the room 
should be well ventilated with all windows open during this period.

8. Humidity levels will rise with the use of your fireplace, but with the usual 

dryness of winter, it will surely be welcomed. Should the humidity become 
overbearing, open the windows for a short period to ventilate the room.

Содержание VFG 600

Страница 1: ...perating Instruction Manual Please read these instructions carefully before installation use and retain them for future reference LP GAS VFG 600 These appliances conform to the requirements of SANS 15...

Страница 2: ...S T Y LE SAF E T Y Q U A LITY THAT L A S T S CONGRATULATIONS o n y o u r p u r c h a s e o f a CHAD O CHEF Fireplace a n d W E L C O M E t o t h e CHAD O CHEF family...

Страница 3: ...ATION REQUIREMENTS 2 INSTALLATION INSTRUCTIONS 3 FOR QUALIFIED GAS INSTALLER 3 NG6801 VALVE Operating Instructions 4 NG6801 VALVE Pressure Testing 4 Checklist For Gas Installer 5 Caution 5 Warnings 6...

Страница 4: ...is the installer s responsibility to do these calculations on behalf of the home owner 6 This appliance may only be installed by a registered LP Gas installer and must comply with the installation re...

Страница 5: ...he fireplace should not be installed within 500mm of any air vent as this could affect the working of the ODS Clearances to combustible materials Combustible materials are defined as wood fabrics or o...

Страница 6: ...lack radiant ceramic ash or glass chips 3 Spread the decorative stone or ceramic evenly around the burner 4 Place the coals or pebbles in a single layer double row spread across the burner allowing ab...

Страница 7: ...use wait 3 minutes before repeating the ignition procedure 4 Continue turning the knob anticlockwise to the HIGH position and the main burner should light after a few seconds 5 Select the required HIG...

Страница 8: ...ecommended with a 10mm gap between them DO NOT use more coals or pebbles than recommended and supplied See Page 2 The room must be bigger than the minimum room size for that fireplace See Page 2 Ensur...

Страница 9: ...WARNING CARBON MONOXIDE POISONING CAN LEAD TO DEATH Carbon monoxide poisoning Early signs of carbon monoxide poisoning resemble the flu with headaches dizziness or nausea If you have these signs the...

Страница 10: ...he biggest pests because they tend to occupy the smallest of holes which will be in the burner venturi or the pilot air holes If spiders are a problem in the home have your fireplace serviced just bef...

Страница 11: ...r This does not mean that it is rust proof it will require regular maintenance to preserve this protective surface layer in order to enjoy the high quality standard that is to be expected from Chad O...

Страница 12: ...Manufactured By Chad o Engineering PO Box 986 Honeydew 2040 Tel 011 668 1910 Email Sales chad o chef co za www chad o chef co za Version 01...

Отзывы: