4
NG6801 VALVE: OPERATING INSTRUCTIONS
NG6801 VALVE: PRESSURE TESTING
The ODS pilot is situated on the side of the burner.
TThe gas control valve is accessible by removing the lower door. Grip both sides
and slide the door up.
Push in and turn the control knob to the pilot position and hold it there for a few
seconds to allow the gas to feed to the pilot.
1. Continue turning anti-clockwise through
the PILOT to click at the SPARK position.
Ensure that the pilot is lit. If not, return to
OFF position and repeat.
2. When the pilot is lit, keep the knob
depressed for approximately 10 to 15
seconds.
3. Now release the knob and the pilot should
stay alight.
If the pilot is extinguished during use, wait
3 minutes before repeating the ignition
procedure.
4. Continue turning the knob anticlockwise to the HIGH position and the main
burner should light after a few seconds
5. Select the required HIGH or LOW setting.
6. To turn the fire OFF, depress the knob and turn it clockwise to the OFF
position and release. This will extinguish both the main burner and the pilot
burner.
iNlET prEssurE
TEsT poiNT
1. Remove the valve cover by gripping both sides and sliding up.
2. Attach inline “Pressure Test Tee” into main inlet line.
3. Adjust line pressure to correct working pressure, whilst fire is set on high.
The pressure should be according to the
data set out in the SPECIFICATIONS. The
fireplace is factory set to work at these
pressures and any significant variation could
indicate a supply problem.
If the pressure is too high or too low, then
check the inlet pressure, by the above
procedure.