27
Technical data
6
3-phase mains connection 400 V
Rated data
6.4
3-phase mains connection 400 V
6.4.1
Rated data
The output currents apply to these operating conditions:
•
At a switching frequency of 2 kHz or 4 kHz: Max. ambient temperature 45°C.
•
At a switching frequency of 8 kHz or 16 kHz: Max. ambient temperature 40 °C.
Inverter
VS30401P8
VS30402P4
VS30403P2
VS30403P9
VS30405P6
VS30401P3
Rated power
kW
0.37
0.55
0.75
1.1
1.5
2.2
Mains voltage range
3/PE AC 340 V ... 528 V, 45 Hz ... 65 Hz
Rated mains current
without mains choke
A
1.8
2.5
3.3
4.4
5.4
7.8
with mains choke
A
1.4
2
2.6
3
3.7
5.3
Output current
2 kHz
A
-
1.8
2.4
3.2
3.9
5.6
4 kHz
A
1.3
1.8
2.4
3.2
3.9
5.6
8 kHz
A
1.3
1.8
2.4
3.2
3.9
5.6
16 kHz
A
0.9
1.2
1.6
2.1
2.6
3.7
Power loss
W
24
31
40
51
61
85
Overcurrent cycle 180 s
Max. output current
A
1.95
2.7
3.6
4.8
5.85
8.4
Overload time
s
60
60
60
60
60
60
Recovery time
s
120
120
120
120
120
120
Max. output current
during the recovery time
A
0.975
1.35
1.8
2.4
2.93
4.2
Overcurrent cycle 15 s
Max. output current
A
2.6
3.6
4.8
6.4
7.8
11.2
Overload time
s
3
3
3
3
3
3
Recovery time
s
12
12
12
12
12
12
Max. output current
during the recovery time
A
0.975
1.35
1.8
2.4
2.93
4.2
Motor cable length
shielded, without EMC
m
15
50
C2 residential area /
industrial premises
m
15
20
Weight
kg
0.75
0.95
1.35
Содержание Emotron VS10
Страница 1: ...Emotron VS10 VS30 AC drive 0 25 2 2 kW Mounting and switch on instruction...
Страница 2: ...This page intentionally left blank...
Страница 10: ...10 4 Mounting Mechanical installation Dimensions VS10 VS30 0 55 kW 0 75 kW All dimensions in mm...
Страница 11: ...11 Mounting Mechanical installation 4 Dimensions VS30 1 1 kW 2 2 kW All dimensions in mm...