6
25
Rated data
Connection to the 230 V system
6.2
1-phase mains connection 230/240 V
6.2.1
Rated data
The output currents apply to these operating conditions:
•
At a switching frequency of 2 kHz or 4 kHz: Max. ambient temperature 45°C.
•
At a switching frequency of 8 kHz or 16 kHz: Max. ambient temperature 40 °C.
Inverter
VS30401P3
VS30401P8
VS30402P4
VS30403P2
VS30403P9
VS30405P6
VS30401P3
Rated power
kW
0.25
0.37
0.55
0.75
1.1
1.5
2.2
Mains voltage range
1/N/PE AC 170 V ... 264 V, 45 Hz ... 65 Hz
Rated mains current
without mains choke
A
4
5.7
7.6
10
14.3
16.7
22.5
with mains choke
A
3.6
4.8
7.1
8.8
11.9
13.9
16.9
Output current
2 kHz
A
-
-
3.2
4.2
6
7
9.6
4 kHz
A
1.7
2.4
3.2
4.2
6
7
9.6
8 kHz
A
1.7
2.4
3.2
4.2
6
7
9.6
16 kHz
A
1.1
1.6
2.1
2.8
4
4.7
6.4
Power loss
W
15
20
25
33
42
50
70
Overcurrent cycle 180 s
Max. output current
A
2.55
3.6
4.8
6.3
9
10.5
14.4
Overload time
s
60
60
60
60
60
60
60
Recovery time
s
120
120
120
120
120
120
120
Max. output current
during the recovery time
A
1.28
1.8
2.4
3.15
4.5
5.25
7.2
Overcurrent cycle 15 s
Max. output current
A
3.4
4.8
6.4
8.4
12
14
19.2
Overload time
s
3
3
3
3
3
3
3
Recovery time
s
12
12
12
12
12
12
12
Max. output current
during the recovery time
A
1.28
1.8
2.4
3.15
4.5
5.25
7.2
Motor cable length
shielded, without EMC
m
50
C2 residential area /
industrial premises
m
15
20
Weight
kg
0.75
0.95
1.35
Содержание Emotron VS10
Страница 1: ...Emotron VS10 VS30 AC drive 0 25 2 2 kW Mounting and switch on instruction...
Страница 2: ...This page intentionally left blank...
Страница 10: ...10 4 Mounting Mechanical installation Dimensions VS10 VS30 0 55 kW 0 75 kW All dimensions in mm...
Страница 11: ...11 Mounting Mechanical installation 4 Dimensions VS30 1 1 kW 2 2 kW All dimensions in mm...